Registers refreshed 2026-11-08.See refresh dates
United States

BASF Corporation

Plastics Laboratory, 450 Clark Drive, 07828, Budd Lake, NJ, United States

Visit website
A2LA 1764.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
9
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D256
ASTM D523Standard Test Method for Specular Gloss
ASTM D570
ASTM D618
ASTM D638Standard Test Method for Tensile Properties of Plastics
ISO 179-1Plastics - Determination of Charpy impact properties - Part 1: Non-instrumented impact test
ISO 188Rubber, vulcanized or thermoplastic - Accelerated ageing and heat resistance tests
ISO 1110Plastics - Polyamides - Accelerated conditioning of test specimens
SAE J2527

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

1764.01

The scope document we hold says it is valid until 2027-11-30.

View scope

Accredited scope, certificate 1764.01

LineMethodMatrixRange
1ASTM D256; ASTM D523; ASTM D570; ASTM D618; ASTM D638Plastics-
2ISO 179-1 Determination of Charpy Impact Properties SAE J2412 Accelerated Exposure of Automotive Interior Trim Components Using a Controlled Irradiance Water-cooled Xenon Arc SAE J2527 Accelerated Exposure of Automotive Exterior Materials Using a Controlled Irradiance Water-cooled Xenon Arc Apparatus UL 94 Flammability ISO 1110 Plastics-Polyamides-Accelerated Conditioning of Test Specimens ISO 188; SAE J2412; SAE J2527Water; Plastics-
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Plastics Laboratory, 450 Clark Drive, Budd Lake, NJ, 07828, US

40.87395, -74.73823

Open in Maps

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.