BASF Corporation
SEPC Operations Quality Control Laboratory, 200 Iris Drive, 38583, Sparta, TN, United States
Visit website- Accredited standards
- 9
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 4 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D618
ASTM D792Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
ASTM D1238
ASTM D3418
ASTM D5630
ISO 1628
ISO 3451-1Plastics - Determination of ash - Part 1: General methods
ISO 11357-1Plastics - Differential scanning calorimetry (DSC) - Part 1: General principles
ISO 15512Plastics - Determination of water content
ASTM D618; ASTM D792; ASTM D1238; ASTM D3418; ASTM D5630-2013
ISO 1628 Determination of the Viscosity of Polymers in Dilute Solution using Capillary Viscometers ISO 3451-1; ISO 11357-1; ISO 15512
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active1217.01
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 1217.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D618; ASTM D792; ASTM D1238; ASTM D3418; ASTM D5630-2013 | Plastics | - |
| 2 | ISO 1628 Determination of the Viscosity of Polymers in Dilute Solution using Capillary Viscometers ISO 3451-1; ISO 11357-1; ISO 15512 | Water; Polymers | - |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
SEPC Operations Quality Control Laboratory, 200 Iris Drive, Sparta, TN, 38583, US
35.92589, -85.46413
Open in MapsOther Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Specialty Testing ServicesLeeds, AL · ~283 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- John J Farber Technology and Innovation CenterRichmond, IN · ~437 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- CTL EngineeringColumbus, OH · ~498 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- ICC Evaluation ServiceElkhart, IN · ~647 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- DDL, Inc.Eden Prairie, MN · ~1,201 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.