Visteon Corporation - GLCC Test Operations
Mail Code 20.1.032, One Village Center Drive, 48111-5711, Van Buren Township, MI, United States
Visit website- Accredited standards
- 9
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000-4-21
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply linesExclusion
Limits written next to it
ISO 7637-3 (excluding ICC method)
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsExclusion
Limits written next to it
ISO 11452-4 (excluding closed-loop
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 11452-11Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 11: Reverberation chamber
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loadsSome clauses
Limits written next to it
ISO 16750-2 (clause 4.6.4 only)
ISO 10605; ISO 10605 (2008); CISPR 25; CISPR 25 (2008), Sections 6.2 and 6.3; CISPR 25; CISPR 25 (2008), Section 6.4; ISO 11452-4; ISO 11452-2; ISO 11452-2 (2004); ISO 11452-11; IEC 61000-4-21; IEC 61000-4-21 (2003, 2011); ISO 7637-2; ISO 16750-2 (clause 4.6.4 only); ISO 7637-3; ISO 11452-9
Read from the A2LA scope documents we downloaded on 2026-08-05 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active1389.01
The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-08-05. Check the A2LA register for the current scope.
Accredited scope, certificate 1389.01
This scope has not been split into individual lines yet. Below is the text of the scope document as published.
Part 1 of 2
(A2LA Cert. No. 1389.03) Revised 07/16/2026 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 VISTEON CORPORATION – GLCC TEST OPERATIONS Visteon Village Electromagnetic Laboratory One Village Center Drive Van Buren Township, MI 48111 Terry Sansouci Phone: 734 710 7137 Email: tsansouc@visteon.com ELECTRICAL Valid to: October 31, 202 Certificate Number: 1389.03 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following automotive electromagnetic compatibility tests: Test Technology: Test Method(s) 1: Electrostatic Discharge (ESD) ISO 10605 RF Conducted Emissions CISPR 25; CISPR 25 (2008), Section 6.2 and 6.3 Radiated Emissions CISPR 25; CISPR 25 (2008), Section 6.4 Bulk Current Injection (BCI) 1 – 400 MHz ISO 11452-4 (excluding closed-loop method and TWC method) Absorber-Lined Shielded Enclosure (ALSE) 100 V/m, 200 MHz to 3.2GHz (excluding Radar Band) ISO 11452-2; ISO 11452-2 (2004) Reverberation Radiated Immunity Mode Tuned IEC 61000-4-21; IEC 61000-4-21 (2003, 2011) Conducted Transient Immunity Along Supply Lines - Conducted Emissions (Time Domain) ISO 7637-2 Conducted Transient on Supply Lines (Electrical Loads) ISO 16750-2 (clause 4.6.4 only) Conducted Transient Immunity Along Lines Other Than Supply Lines ISO 7637-3 (excluding ICC method) Portable Transmitters ISO 11452-9 1 This lab uses the above listed standards and test methods in addition to client directed, product specific requirements for BMW, Chrysler, Ford, General Motors, Honda, Mercedes, Woodward, Nissan, Porsche (Volkswagen), Jaguar Land Rover, Mazda, Tesla, Mitsubishi, Daimler-Benz, and Faraday Future.
Part 2 of 2
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited VISTEON CORPORATION - GLCC TEST OPERATIONS Van Buren Township, MI for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 19th day of September 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1389.03 Valid to October 31, 2026 Revised July 16, 2026
Extracted from the scope document; tables may not line up. View scope for the original.
ISO/IEC 17025
Active1389.03
The scope document we hold says it is valid until 2028-07-31.
Accredited scope, certificate 1389.03
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 10605; ISO 10605 (2008); CISPR 25; CISPR 25 (2008), Sections 6.2 and 6.3; CISPR 25; CISPR 25 (2008), Section 6.4; ISO 11452-4; ISO 11452-2; ISO 11452-2 (2004); ISO 11452-11; IEC 61000-4-21; IEC 61000-4-21 (2003, 2011); ISO 7637-2; ISO 16750-2 (clause 4.6.4 only); ISO 7637-3; ISO 11452-9 | automotive | - |
| 2 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Mail Code 20.1.032, One Village Center Drive, Van Buren Township, MI, 48111-5711, US
42.22080, -83.48415
Open in MapsLabs with overlapping accredited scope in United States
- UL LLCNovi, MI · ~29 kmA2LAShares 1 accredited test methodISO 10605
- APTIV WESTFIELD TESTWestfield, IN · ~330 kmA2LAShares 1 accredited test methodISO 10605
- Radiometrics Midwest CorporationRomeoville, IL · ~386 kmA2LAShares 1 accredited test methodISO 10605
- HV TECHNOLOGIESManassas, VA · ~638 kmA2LAShares 1 accredited test methodISO 10605
- Compliance Management Group (CMG)Marlboro, MA · ~1,027 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.