CETECOM
411 Dixon Landing Road, 95035, Milpitas, CA, United States
Visit website- Accredited standards
- 39
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 39 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+2 national
National versions in the same scope
CNS 14676-2identical to it
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+2 national
National versions in the same scope
CNS 14676-4identical to it
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+2 national
National versions in the same scope
CNS 14676-5identical to it
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+2 national
National versions in the same scope
CNS 14676-6identical to it
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+2 national
National versions in the same scope
CNS 14676-8identical to it
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+2 national
National versions in the same scope
CNS 14676-11identical to it
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
ETSI10
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-33
ETSI EN 301 489-52
ETSI EN 302 502
ETSI EN 302 858
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 24identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
KS C 9835national version with changes
EN4
EN 50360
EN 50364
EN 50371
EN 50566
IEC3
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO/IEC 17025:2017; 47 CFR FCC Part 15 B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; AS/NZS CISPR 11; KS C 9811; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32 (excluding broadcast receivers); EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32:2016; KS C 9832:2019; RRA Public Notification 2017-19, Dec 28, 2017; RRA Announce 2017-71, Dec 28, 2017; CNS 13438; IEC 60601-1-2; EN 60601-1-2; ICES-003; EN 61000-3-2; IEC 61000-3-2; KS C 9610-3-2; CNS 14934-2; EN 61000-3-3; IEC 61000-3-3; KS C 9610-3-2; CNS 14934-3; IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-3; EN 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-33; EN 301 489-52; KS X 3124:2020; KS X 3125:2020; KS X 3126:2020; KS X 3129:2020; AS/NZS 61000.6.1; CISPR 24; EN 55035; KS C 9835:2019; CNS 14675; AS/NZS CISPR 24; EN 55024; EN 61000-4-2; IEC 61000-4-2; KS C 9610-4-2; CNS 14676-2; EN 61000-4-3; IEC 61000-4-3; KS C 9610-4-3; CNS 14676-3
EN 61000-4-4; IEC 61000-4-4; KS C 9610-4-4; CNS 14676-4; EN 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; CNS 14676-5; EN 61000-4-6; IEC 61000-4-6; KS C 9610-4-6; CNS 14676-6; EN 61000-4-8; IEC 61000-4-8; KS C 9610-4-8; CNS 14676-8; EN 61000-4-11; IEC 61000-4-11; KS C 9610-4-11; CNS 14676-11; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; ISO 7637-2; ISO 7637-3; 47 CFR FCC Part 15 C, E, F; ANSI C63.10:2020; FCC KDB 905462 D02 (v02); 47 CFR FCC Part 15D; ANSI C63.17:2015; 47 CFR FCC Parts 22, 24, 25, 27, 30, 74, 90, 95, 96, 97, and 101; ANSI/TIA 603-E; ANSI C63.26:2015; ANSI C63.10:2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a:2024; RSS-GEN; RSS-102; RSS-102.NS.MEAS; RSS-111; RSS-112; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-140; RSS-142; RSS-170; RSS-191; RSS-192; RSS-193; RSS-194; RSS-195; RSS-196; RSS-197; RSS-198; RSS-199; RSS-210; RSS-211; RSS-213; RSS-215; RSS-216; RSS-220; RSS-222; RSS-236; RSS-238; RSS-243; RSS-244; RSS-246; RSS-247; RSS-248; RSS-251; RSS-252; RSS-287; RSS-288; QCVN 54:2020/BTTTT; QCVN 55:2011/BTTTT; QCVN 18:2014/BTTTT; QCVN 65:2013/BTTTT; TCVN 7189:2009; TCVN 7317:2003; AS/NZS 4771; AS 2772.2; AS/NZS 4268; MSIT Public Notification 2018-38; KS X 3123; LP0002 Section 3.10 & 4.7; N1: Specified Radio Equipment Specified in Article 38-2-2, Paragraph 1, Item 1 of the Radio Law; Article 49-20, 21 of the Ordinance Reg
EN 302 502; EN 302 858; EN 303 413; EN 303 417; ARIB T-33; ARIB T-66; ARIB T-71; NOM 121-SCT1-2009; EN 50360; EN 50371; EN 62311; EN 62479; EN 50364; EN 50566; RSS-102; RSS-102.NS.MEAS; CTIA Test Plan for Wireless Device Over-the-Air Performance 2; CTIA Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices 2; T-MOBILE; AT&T; SPRINT; VODAFONE; VzW LTE Over the Air Radiated Performance Test Plan; VzW Over the Air Radiated Performance for CDMA & LTE Multimode Devices Test Plan; VzW 5G_NR_FR1_RFOTA; WMM System Interoperability Test Plan with Test Engine; WMM Power Save System Interoperability Test Plan; Wi-Fi WPS Test Plan Wi-Fi Alliance; 802.11n 2.0 System Interoperability Test Plan; 802.11 ac, Voice Personal; Miracast; Wi-Fi Direct; WMM-AC; Passpoint; Wi-Fi 6/E; C63.27:2021; IEEE/ANSI C63.27; WINNF-TS-0122; WPC Qi Specification PTx, PRx; PTCRB; 3GPP TS 34.114; 3GPP TS 25.144; 3GPP TS 34.124; 3GPP TS 36.124; 3GPP TS 38.124; AS/ACIF S042.1; 3GPP TS.26.132; 3GPP2 CS0056-A; VzW Codec and Voice Quality; CTIA Speech Performance Test Plan 2
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; FCC KDB 905462 D02 (v02) April 08, 2016; ANSI/TIA-603-E; ANSI C63.26:2015
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active2135.01
The scope document we hold says it is valid until 2027-12-31.
ISO/IEC 17065
Active2135.03
The scope document we hold says it is valid until 2027-12-31.
Location
Labs with overlapping accredited scope in United States
- HCT AmericaMilpitas, CA · ~3 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Vista Laboratories, Inc.San Clemente, CA · ~594 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- ElectroMagnetic InvestigationsHillsboro, OR · ~901 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAFridley, MN · ~2,524 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- TUV SUD AmericaNew Brighton, MN · ~2,528 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.