Siemens Mobility GmbH Typtestzentrum Braunschweig
Ackerstraße 22, 38126, Braunschweig, Germany
- Accredited standards
- 34
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 34 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series16
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-14
IEC 61000-4-17
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60068 series10
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-53
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN3
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50155Railway applications - Rolling stock - Electronic equipment
Other standards1
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
DIN EN 55011; VDE 0875-11:2018; DIN EN 55022 (VDE 0878-22): 2011; CISPR 22: 2008; DIN EN 61000-3-2; VDE 0838-2:2015; DIN EN 61000-3-3; VDE 0838-3:2014; DIN EN 50155 (03/2008)
DIN EN 61000-4-2; VDE 0847-4-2:2009; EN 61000-4-3; VDE 0847-4-3:2011; DIN EN 61000-4-4; VDE 0847-4-4: 2013; DIN EN 61000-4-5; VDE 0847-4-5: 2019; DIN EN 61000-4-6; VDE 0847-4-6: 2014; DIN EN 61000-4-8; VDE 0847-4-8: 2010; DIN EN 61000-4-9
VDE 0847 -4-9: 2017; EN 61000-4-9; DIN EN 61000-4-11; VDE 0847-4-11: 2019; EN 61000-4-11; DIN EN 61000-4-14; VDE 0847-4-14: 2010; EN 61000-4-14; DIN EN 61000-4-17/A2; VDE 0847-4-17/A2: 2009; EN 61000-4-17/A2; DIN EN 55016-2-1; VDE 0877-16-2-1: 2019; CISPR 16-2-1: 2014
CISPR 16-2-1; DIN EN 55016-2-3; DIN EN 61000-6-1; VDE 0839-6-1; CISPR 16-2-3
DIN EN 61000-6-2; VDE 0839-6-2:2006; DIN EN 61000-6-3; VDE 0839-6-3:2011; DIN EN 61000-6-4; VDE 0839-6-4:2011; EN 50121-3-2: 2016-12 +A1:2019; EN 50121-4: 2016-12 +A1:2019
EN 50155; Regelung Nr. 06; DIN EN 61373; DIN EN 60068-2-1; VDE 0468-2-1:2008; DIN EN 60068-2-2; VDE 0468-2-2:2008; DIN EN 60068-2-14; DIN EN 60068-2-30; DIN EN 60068-2-78; DIN EN 60068-2-6; VDE 0468-2-6:2008
DIN EN 60068-2-27; VDE 0468-2-27:2010; DIN EN 60068-2-31; VDE 0468-2-31:2009; DIN EN 60068-2-64; VDE 0468-2-64:2009; DIN EN 60068-2-53
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
10 lines
ISO/IEC 17025
ActiveD-PL-21237-01-00
ISO/IEC 17025
ActiveD-PL-21237-01-01
Location
Labs with overlapping accredited scope in Germany
- PHOENIX TESTLABBlomberg · ~105 kmDAKKSShares 3 accredited test methodsEN 50155EN 61000-4-11EN 61000-6-3
- HARTING Stiftung & Co. KG Corporate Technology Services (CTS)Espelkamp · ~131 kmDAKKSShares 2 accredited test methodsEN 50155EN 61000-4-3
- RS Schwarze Industrieelektronik GmbH EMV-LaboratoriumSchloss Holte-Stukenbrock · ~137 kmDAKKSShares 2 accredited test methodsEN 61000-4-3EN 61000-6-3
- CEcertWismar · ~193 kmDAKKSShares 2 accredited test methodsEN 50155EN 61000-4-3
- DEKRA Testing and CertificationStuttgart · ~405 kmDAKKSShares 2 accredited test methodsEN 61000-4-3EN 61000-6-3
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.