BS 1377-4 Accredited Testing Labs in United Kingdom

28 laboratories in United Kingdom are accredited by UKAS to perform BS 1377-4 testing. We don't know yet whether 8 of them take outside work. From the accredited scope text: “BS 1377-4:1990 A Dry density/moisture content relationship (4.5 kg rammer) BS 1377-2:2022 BS 1377-4:1990 A Dry density/moisture content relationship (Vibrating Hammer) BS 1377-2:2022 BS 1377-4:1990 A” “BS 1377-4:1990 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Laboratory California Bearing Ratio (CBR) BS 1377-4:1990 Laboratory Undrained shear strength – triaxi” “BS 1377-4:1990 Lab” “BS 1377-4:1990 BS 1377-2:2022 Lenham Lenham (cont’d) In-situ density - sand replacement method (large pouring cylinder method) BS 1377-9:1990 Site In-situ density - core cutter method BS 1377-9:1990 S”

Labs
28
Primary AB
UKAS28 labs

Accredited Labs

TD Construction Testing

Merseyside, GB

Scope

BS 1377-4:1990 A & B MCV (natural water content) BS 1377-2:2022 A & B Dry density / moisture content relationship – 2.5kg rammer BS 1377-4:1990 A Dry density / water content relationship – 2.5kg rammer BS 1377

View lab

MATtest Site Services

East Kilbride, GB

Scope

BS 1377-4:1990 X Sampling soils - from undisturbed material - from disturbed material Documented In-House Method No TOP 1:2018 X Dynamic cone penetrometer Documented In-House Method No TOP 9:2009 X Vertical defor

View lab

Humberside Materials

North Lincolnshire, GB

Scope

BS 1377-4:1990 BS 1377-2:2022 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 BS 1377-2:2022 Laboratory Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990

View lab

GEO Site and Testing Services

Carmarthenshire, GB

Scope

BS 1377-4:1990 BS 1377-2:2022 Laboratory One-dimensional consolidation properties BS 1377-5:1990 Laboratory Permeability in a triaxial cell BS 1377-6:1990 Laboratory Shear strength by direct shear (small shearbox

View lab

Soil Property Testing

Huntingdon, GB

Scope

BS 1377-4:1990 A Dry density/water content relationship (2.5 kg rammer) BS 1377-2:2022 A Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 A Dry density/water content relationship (4.5 kg ram

View lab

M & H Testing

Kent, GB

Scope

BS 1377-4:1990 BS 1377-2:2022 Lenham Lenham (cont’d) In-situ density - sand replacement method (large pouring cylinder method) BS 1377-9:1990 Site In-situ density - core cutter method BS 1377-9:1990 Site Ve

View lab

Terra Tek Limited trading as Igne

Bellshill, GB

Scope

BS 1377-4:1990 Aston Clinton Bellshill Dry density/water content relationship (2.5 kg rammer) BS 1377-2:2022 Daventry Bellshill Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Aston Clinton Be

View lab

SOCOTEC UK

Middlesex, GB

Scope

BS 1377-4:1990 Lab

View lab

Grampian Geotechnical (Scotland)

Aberdeenshire, GB

Scope

BS 1377-4:1990 A Dry density/moisture content relationship (4.5 kg rammer) BS 1377-2:2022 BS 1377-4:1990 A Dry density/moisture content relationship (Vibrating Hammer) BS 1377-2:2022 BS 1377-4:1990 A Determin

View lab

Construction Testing Solutions

Doncaster, GB

Scope

BS 1377-4: 1990 Site MCV - natural water content BS1377-2: 2022 Site In-situ density - sand replacement method (small pouring cylinder) BS 1377-9: 1990 Site In-situ density - sand replacement method (large pouri

View lab

Ground Technology Services Ltd T/A ASC Geotesting

Norfolk, GB

Scope

BS 1377-4:1990 Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 California Bearing Ratio (CBR) BS 1377-4:1990 California Bearing Ratio (CBR) - soaked BS 1377-4:1990

View lab

G2M Testing

Durham, GB

Scope

BS 1377-4:1990 A, B Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 A, B Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 A Moisture condition value (MCV) - na

View lab

DGL Testing Services

Kent, GB

Scope

BS 1377-4:1990 Laboratory Dry density/water content relationship (2.5 kg rammer) BS 1377-2:2022 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Laboratory Dry density/water conten

View lab

Aitken Laboratories Ltd

Stirlingshire, GB

Scope

BS 1377-4:1990 Dry density / moisture content relationship (4.5 kg rammer) BS 1377-4:1990 California Bearing Ratio (CBR) BS 1377-4:1990 One-dimensional consolidation properties BS 1377-5:1990 Undrained shear stre

View lab

BAM Nuttall Limited trading as BAM Ritchies

Glasgow, GB

Scope

BS 1377-4:1990 A, D*, F*, Flexi Dry density/moisture content relationship - vibrating hammer BS 1377-2:2022 A, Flexi Moisture condition value (MCV) BS 1377-4:1990 A, C*, D* F*, Flexi Moisture condition value (M

View lab

Simtec Materials Testing

East Goscote, GB

Scope

BS 1377-4:1990 Leicester Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Leicester Moisture condition value (MCV) BS 1377-4:1990 Leicester MCV - natural moisture content BS 1377-4:1990 Lei

View lab

Geotechnics

Coventry, GB

Scope

BS 1377-4:1990 Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 Moisture condition value (MCV) at natural moistur

View lab

Soil Engineering Geoservices

Leeds, GB

Scope

BS 1377-4:1990 BS 1377-2:2022 Laboratory Moisture condition value (MCV) TRL Report 273 : Use and application of the MCA with particular reference to glacial tills. (G D Matheson & M G Winter) Laboratory Chalk crushing

View lab

C J Associates Geotechnical

Bridgend, GB

Scope

BS 1377-4:1990 B Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 B In-situ density - sand replacement method (large pouring cylinder) BS 1377-9:1990 C In-situ density - core cutter method

View lab

Earthworks Testing

Doncaster, GB

Scope

BS 1377-4:1990 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Laboratory Dry density/moisture content relationship (Vibrating Hammer) BS 1377-4:1990 Laboratory California Bearin

View lab

Balfour Beatty Civil Engineering

Falkirk, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 A,B,C Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 A,B,C Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 A,B,C Moisture condition value BS 1377

View lab

Morgan Sindall Construction and Infrastructure

Coventry, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 NoL* Beckton* In-situ density - sand replacement method - large pouring cylinder BS 1377-9:1990 NoL* Beckton* In-situ density - core cutter method BS 1377-9:1990 NoL * Particle density – gas Ja

View lab

Costain

London, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 UB9*, NW10* Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 UB9*, NW10* Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 UB9*, NW10* MCV - natura

View lab

Northumberland County Council

Northumberland, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Laboratory California Bearing Ratio (CBR) BS 1377-4:1990 Laboratory Undrained shear strength – triaxial compression w

View lab

Wills Bros. Civil Engineering Limited trading as Total Construction Materials Testing Services

Airdrie, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:2022 A B C X Temp Dry density/moisture content relationship - (2.5 kg rammer) - (4.5 kg rammer) - (vibrating hammer) BS 1377-2:2022 BS 1377-4:1990 A B C Temp

View lab

Volker Fitzpatrick

Hertfordshire, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 E Sand replacement – Small pouring cylinder method BS 1377-9:1990 B,E Sand replacement – Large pouring cylinder method BS 1377-9:1990 A,E Vertical deformation and strength characteristics by the inc

View lab

Surrey County Council

Surrey, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 Laboratory Dry density/moisture content relationship (4.5 kg rammer) BS 1377-4:1990 Laboratory Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 Laboratory California Bearin

View lab

Laing O’Rourke Infrastructure

Kent, GB

We don't know yet whether this lab takes outside work.
Scope

BS 1377-4:1990 HPC Dry density/moisture content relationship (4,5 kg rammer) BS 1377-4:1990 NCL Dry density/moisture content relationship (vibrating hammer) BS 1377-4:1990 HPC Moisture condition value

View lab

About ISO/IEC 17025 in United Kingdom

United Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.