Anchem Laboratories Ltd
West Glamorgan, GB
EN 14789:2017 (ANC/S/26 - Validated Zirconium cell/Paramagnetic analyser) C Carbon Monoxide* BS EN 15058:2017 (ANC/S/29 - NDIR analyser) C
10 laboratories in United Kingdom are accredited by UKAS under ISO/IEC 17025 to perform EN 14789:2017 testing. These labs commonly handle Stack emissions to atmosphere, Water matrices. Most frequently tested analytes via this method in United Kingdom: Oxygen. From the accredited scope text: “EN 14789:2017 (QPAS/B/538 - Validated paramagnetic analyser) (QPAS/B/538 - Validated zirconium cell analyser) (QPAS/B/538 - Validated electrochemical cell analyser) C Total Gaseous Organic Carbon* (TO” “EN 14789:2017 (S-02 - Validated Zirconium cell analyser) (S-02 - Paramagnetic analyser) B Total Gaseous Organic* Carbon (TOC / VOC) (0 to 1000 mg/m³) BS EN 12619:2013 (S-08 - FID Analyser) B Stack Emi” “EN 14789:2017 (MD-021 - Validated Zirconium cell analyser) (MD-022 - Validated Zirconium cell analyser) (MD-025 - Paramagnetic analyser) (MD-033 - Paramagnetic analyser) (MD-039 - Paramagnetic analyse” “EN 14789:2017 (ANC/S/26 - Validated Zirconium cell/Paramagnetic analyser) C Carbon Monoxide* BS EN 15058:2017 (ANC/S/29 - NDIR analyser) C”
West Glamorgan, GB
EN 14789:2017 (ANC/S/26 - Validated Zirconium cell/Paramagnetic analyser) C Carbon Monoxide* BS EN 15058:2017 (ANC/S/29 - NDIR analyser) C
Stockport, GB
EN 14789:2017 (MD-021 - Validated Zirconium cell analyser) (MD-022 - Validated Zirconium cell analyser) (MD-025 - Paramagnetic analyser) (MD-033 - Paramagnetic analyser) (MD-039 - Paramagnetic analyser) EST Total Gaseous O
Glasgow, GB
EN 14789:2017 (WI/EM/1273 - Validated Zirconium cell analyser) B Sulphur dioxide* PD CEN/TS 17021:2017 (WI/EM/0058 – NDIR analyser) B Total Gaseous Organic* Carbon (TOC / VOC) (0 to 1000 mgC/m³) BS EN 12619: 2013 (WI/
Leeds, GB
EN 14789:2017 (S-02 - Validated Zirconium cell analyser) (S-02 - Paramagnetic analyser) B Total Gaseous Organic* Carbon (TOC / VOC) (0 to 1000 mg/m³) BS EN 12619:2013 (S-08 - FID Analyser) B Stack Emissions - Continuou
Staffordshire, GB
EN 14789:2017 (AE 102- Paramagnetic analyser) (AE 102 - Validated Zirconium cell analyser) Stacks Total Gaseous Organic Carbon (TOC/VOC) (0 to 1000 mg/m³) IS EN 12619:2013 (AE 102 - FID analyser) Stacks
Middlesex, GB
EN 14789:2017 (QPAS/B/538 - Validated paramagnetic analyser) (QPAS/B/538 - Validated zirconium cell analyser) (QPAS/B/538 - Validated electrochemical cell analyser) C Total Gaseous Organic Carbon* (TOC / VOC) (0 to 1000 mg/m
Reading, GB
EN 14789:2017 (SP14789 - Paramagnetic analyser) B Nitrogen Monoxide (NO)* BS EN 14792:2017 (SP14792 - Chemiluminescence analyser) B Nitrogen Dioxide (NO2)* BS EN 14792:2017 (SP14792 - Chemiluminescence analyser) B
West Yorkshire, GB
EN 14789:2017 (ETC-SE-10 - Paramagnetic analyser) B BS EN 14789:2017 B (TP-22d - Paramagnetic analyser)
Staffordshire, GB
EN 14789:2017 (WI 4/41 - Validated Zirconium cell analyser) BS EN 14789:2017 (WI 4/41 - Paramagnetic analyser) B Total Gaseous Organic Carbon* (TOC / VOC) (0 to 1000 mg/m³) BS EN 12619:2013 (WI 4/28 - FID analyser) B
Pontypridd, GB
EN 14789:2017 (ECL/TPD/033c & 033d - Validated Zirconium cell/Paramagnetic analyser) (ECL/TPD/086 - Validated Electrochemical cell analyser) (ECL/TPD/097 and ECL/TPD/098 – Validated Zirconium cell analyser) A, B Ammonia* PD
This page is a fixed slice of the register: every EN 14789:2017 scope we hold for United Kingdom. Search narrows it further by city, accreditation body, or a term from the scope text itself.
Search labs in United KingdomUnited Kingdom Accreditation Service (UKAS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United Kingdom.
ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.