Registers refreshed 2026-11-20.See refresh dates

IEC 60669 Accredited Testing Labs Worldwide

IEC 60669, all parts. Each lab card shows which parts it holds.

49 accredited laboratories in 7 countries hold IEC 60669 in their accredited scope. Primary accreditors include Deutsche Akkreditierungsstelle, American Association for Laboratory Accreditation, Italian Accreditation Body.

Total labs
49
Countries
7

Available in 7 Countries

Germany
24 labs
China
6 labs
Italy
6 labs
Poland
2 labs
Australia
1 lab
Netherlands
1 lab
United States
1 lab

Sample labs

STC Germany
Frontenhausen, DE
Holds: Part 2-1 · Part 2-2 · Part 2-3 · Part 2-5

IEC 60669-2-1:2002 + A1:2008) only EMC EM V BS EN 60669-2-2:2006 (EN 60669-2-2:2006) Switches for household and similar fixed electrical installations – Part 2: Particular requirements – Section 2: Electromagnetic remote- control s

TÜV Technische Überwachung Hessen GmbH EMV-Labor
Kassel, DE
Holds: Part 2-1 · Part 2-2 · Part 2-3

IEC 60669-2-1:2023 VDE 0632-2-1:2023 (EN IEC 60669-2-1:2022 + A11: 2022) Schalter für Haushalt und ähnliche ortsfeste elektrische Installationen - Teil 2- 1: Besondere Anforderungen - Elektronische Schalter (IEC 60669-2- 1:2021, mod

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3 · Part 2-4 · Part 2-5 +1 more

IEC 60669-1:1998 EN 60669-1:2009 Schalter für Haushalt und ähnliche ortsfeste elektrische Installationen - Teil 1: Allgemeine Anforderungen A IEC 60669-1:2006 Switches for household and similar fixed installations – Part 1: General

CSA Group Bayern
Plattling, DE
Holds: Part 2-1 · Part 2-2 · Part 2-3

IEC 60669-2-1:2002, modifiziert + A1:2008, modifiziert) EMV DIN EN 60669-2- 2:2007 VDE 0632-2-2:2007 (EN 60669-2-2:2006) Schalter für Haushalt und ähnliche ortsfeste elektrische Installationen - Teil 2-2: Besondere Anforderungen -

Stowarzyszenie Elektryków Polskich, ul. Świętokrzyska 14, 00-050 Warszawa, Biuro Badawcze ds. Jakości
Warszawa, PL
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3 · Part 2-5

IEC 60669-1:2017 PN-EN 60669-1:2006 + A2:2008 + IS1:2009 EN 60669-1:1999 + A1:2002 + A2:2008 + IS1:2009 IEC 60669-1:1998 + Amd1:1999 + Amd2:2006 PN-EN 50428:2010 EN 50428:2005 + A1:2007 +A2 :2009 p. 26 PN-E-93151:2012 - łączniki

Eurofins Product Service
Reichenwalde, DE
Holds: Part 2-1 · Part 2-2

IEC 60669 -2- 1:2022 Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic control devices (IEC 60669-2-1:2021) Nur Abschn. 26 / Only section 26 EMV / EMC IEC 60669-2- 1:20

steep GmbH EMV-Zentrum
Bonn, DE
Holds: Part 1 · Part 2-1 · Part 2-2

IEC 60669-2- 2:2006); Deutsche Fassung EN 60669-2- 2:2006 Kapitel 26 EMV IEC 60669-2-2:2006 Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote- control switches

TÜV SÜD Product Service GmbH PS-SL-EMC / PS-SL-ENV-STR
Straubing, DE
Holds: Part 1 · Part 2-1 · Part 2-2

IEC 60669 -2-1:2002 + A1:2008 Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches EMV - Anforderungen gemäß Abschnitt 26 EMV DIN EN 60669 -2-2; VDE 0632-2-2

EMCCons Dr. RASEK GmbH & Co. KG
Ebermannstadt, DE
Holds: Part 2-2 · Part 2-3

IEC 60669 -2-2:2006 Switches for household and similar fixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS) EMV EN 60669 -2-2:2006 Schalter für Haushalt und ähnliche

PHOENIX TESTLAB
Blomberg, DE
Holds: Part 2-1 · Part 2-2 · Part 2-3

IEC 60669-2- 2:2006); Deutsche Fassung EN 60669-2-2:2006 nur Kapitel 26 EMV IEC 60669-2-2 ed. 3.0: 2006 Switches for household and similar fixed electrical installations – Part 2-1: Particular requirements – Electromagnetic remote-co

SLG Prüf- und Zertifizierungs
Hartmannsdorf, DE
Holds: Part 2-1 · Part 2-2 · Part 2-3

IEC 60669 -2-2:2006 Switches for household and similar fixed electrical installations - Part 2: Particular requirements - Section 2: Electromagnetic remote-control switches (RCS) EM C DIN EN 60669 -2-3: 2007-05 Switches for househo

TUV SUD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Shenzhen, CN
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3 · Part 2-5

IEC 60669-1; EN 60669-1 ; BS EN 60669-1; SANS 60669-1; AS/NZS 60669.1; GB 16915.1 Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements - Electronic switches IEC 60669-2-1; EN IEC 6

LABORATOIRE PUBLIC D'ESSAIS ET D'ETUDES (LPEE) - CENTRE D'ESSAIS ET D'ETUDES ELECTRIQUES (CEEE)
CASABLANCA, MA
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3

ELECTRICITE / Eléments d’appareillage électrique pour installations domestiques et analogues / Essais de sécurité et de performance (21) Nature de l’essai Nature of test Objet soumis à essai Object under test Principe de la méthode Pr

Sieć Badawcza Łukasiewicz - Instytut Mikroelektroniki i Fotoniki
Warszawa, PL
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3 · Part 2-4

Przedmiot badań/wyrób Rodzaj działalności/badane cechy/metoda Dokumenty odniesienia Systemy bezprzerwowego zasilania (UPS) Emisja napięcie zaburzeń ciągłych na zaciskach, przewodzonych (9kHz – 30MHz) Emisja, natężenie pola zab

CENTRO DE ENSAYOS, INNOVACIÓN Y SERVICIOS, S.L. (CEISLAB)
Móstoles, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2-1 · Part 2-2 · Part 2-3 · Part 2-5

IEC 60669-2-1 UNE-EN 60669-2-1 IEC 60669-2-1 Excepto Apdo./Except Section 26 A Interruptores con mando a distancia para instalaciones domésticas fijas Electromagnetic remote- control switches for household fixed-electrical install

SCHNEIDER ELECTRIC ESPAÑA
Meliana, ES
We don't know yet whether this lab takes outside work.
Holds: Part 1 · Part 2-2 · Part 2-4

IEC 60669-1 Interruptores para instalaciones eléctricas fijas, domésticas y análogas. Interruptores de mando electromagnético a distancia (telerruptores), e xcepto los interruptores operados indirectamente, con cuerda o con mane

Siemens Aktiengesellschaft DI FA DSP SYS TT 2
Erlangen, DE
We don't know yet whether this lab takes outside work.
Holds: Part 2-1 · Part 2-2 · Part 2-3

IEC 60669 -2-2:2006 Switches for household and similar f ixed electrical installations - Part 2-2: Particular requirements - Electromagnetic remote-control switches (RCS) EMV EN 60669 -2-3 DIN EN 60669-2-3 Schalter für Haushalt und