FindTestingLabs
Registers refreshed 2026-10-25.See refresh dates

ISO 10360-2 Accredited Testing Labs Worldwide

Part of a series

See all 10 labs worldwide for ISO 10360 (any part)

Part 2: 9 labs · Part 5: 5 labs · Part 7: 3 labs · Part 8 (CMMs with optical distance sensors): 1 lab · Part 9 (CMMs with multiple probing systems): 1 lab · Part 12: 2 labs and 1 more part

Go to the series ↑

8 accredited laboratories in 4 countries hold ISO 10360-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation.

Total labs
8
Countries
4

Available in 4 Countries

United States
4 labs
Mexico
2 labs
Canada
1 lab
Taiwan
1 lab

Top analytes for ISO 10360-2

  • Diameter (1)
  • Length (1)
  • Length Measurements (1)

Sample labs

KES Machine
Newington, CT, US

ISO 10360-2 using gage block Laser interferometer Note: ISO 10360-2 tests both volumetric and linear scale accuracy. Probing Error3 (CMM) 30 mm 0.18 µm ISO 10360-5 using master sphere Angle3 – Machine Tools

Trescal, Inc - Milwaukee, WI
Milwaukee, WI, US

Parameter/Equipment Range CMC2, 4, 8 (±) Comments CMMs – Imaging (Video CMMs/Vision Systems)3 Length Measurements: EUX, EUY, EUXY EUV EZ Squareness – ESQ Probing Performance PF2D, PFV2D XY Diagonal Up

Borbolla Metrology, S.A. de C. V.
Zona Centro, Saltillo, Coah., MX

ISO 10360-2 sections 6.3.3, 6.4 and 6.5: Step gage and gage blocks Gage blocks, Renishaw laser ISO 10360-5:2010 Section 6.2: Test sphere Optical Comparators & Vision Systems3,5 – X & Y Axis Length Er

East Coast Metrology a Division of In-Place Machining Company
Topsfield, MA, US

ISO 10360-2 and -5 Reference sphere per ISO 10360-2 and -5 Check Master per ISO 10360-2 and -5 Check Master per ISO 10360-2 and -5 Laser interferometer per ISO 10360-2 and -5 Ball bar per ISO 10360- 2 and -5 Line

Analisis por Instrumentos y Software para CMM's SA de CV., dba Soporte Metrology
Puebla, Puebla, MX

ISO 10360-2 ASME B89.4.10360.2: Laser interferometer & gage blocks Gage blocks ISO 10360-5:2010 Test sphere ISO 10360-5:2020 Test sphere

DEKRA IST Reliability Services
Hsinchu, TW

ISO 10360-2 1When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one year from the date of publication of

Mitutoyo Canada Inc. Calibration Laboratory
Mississauga, ON, CA

ISO 10360-2 2009 edition and 2001 edition Optic Coordinate Measuring Machines 10, 11 Length Measurement Error: EUXY EUZ Squareness Error: ESQ Probing Error: PF2D PFV2D Up to 600 mm (0.25 +

Omni-Tech Corporation
Fenton, MI, US

ISO 10360-2 using gauge block ISO 10360-2 using gauge block ISO 10360-5 using sphere ANSI/ASME B89.4.1b-2001 Ball bar ANSI/ASME B89.4.1b-2001 Laser ANSI/ASME B89.4.1b-2001 ISO 10360-2 ____________________________

Other parts