Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

IEC 61000-4-2 Accredited Testing Labs in Germany

107 laboratories in Germany are accredited by DAKKS to perform IEC 61000-4-2 testing. We don't know yet whether 54 of them take outside work. From the accredited scope text: “IEC 61000-4-2:2008 IEC 61000-4-2:2025 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test” “IEC 61000-4-2: 1995 + A1: 1998 + A2: 2001)” “IEC 61000-4-2:2008); German version EN 61000- 4-2:2009 PB) EMC IEC 61000 -4-3 :2006 + A1:2007 + A2:2010 Electromagnetic compatibility (EMC) - Part 4 - 3: Testing and measurement techniques - Radiated,” “IEC 61000-4-2:1995/A1:1998); Deutsche Fassung EN 61000-4-2:1995/A1:1998 EMV DIN EN 61000-4-2:2009-12 VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil 4-2: Prüf- und Messverfahren -”

Labs
107
Primary AB
DAKKS107 labs

Accredited Labs

Gütegemeinschaft Schlösser und Beschläge e.V. PIV Prüfinstitut Schlösser und Beschläge Velbert

Velbert, DE

Scope

IEC 61000-4-2:2008) 1.2 Product family standards 1.2.1 Locks and building hardware EMC DIN EN 14846 2008-11 Building hardware - Locks and latches - Electromechanically operated locks and striking plates - Requirements and tes

View lab

AKUVIB Engineering and Testing

Bochum, DE

Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN 61000-4-3 VDE 0847 Teil 4-3: 2011 (EN 61000-4- 3+A1+A2) Elektromagnetische Verträglichkeit (EMV)- Teil 4-3: Prüf - und Messverfahren- Prüfung der Störfestigkeit ge

View lab

TÜV NORD CERT

Essen, DE

Scope

IEC 61000-4-2:2008) Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN IEC 61000-4-3: 2021- 11 VDE 0847-4-3:2021-11 Elektromagnetische Verträglichkeit (EMV) – Teil 4-3: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen hochfreq

View lab

Continental Automotive Technologies GmbH EMV Prüflaboratorium

Babenhausen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2001); Deutsche Fassung (EN 61000-4-2:1995 + A1:1998 + A2:2001) EMV DIN EN 61000-4-2; VDE 0847-4-2:2009 (EN 61000-4-2) Elektromagnetische Verträglichkeit (EMV) - Teil 4-2: Prüf- und Messverfahren - Prüfung der Störf

View lab

Siemens Aktiengesellschaft EMV Labor RBG S 10

Regensburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV IEC 61000 -4-2:2008 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV DIN EN 61000 -4-3 (

View lab

Endress+Hauser SE+Co. KG

Maulburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test EMC DIN EN 61000-4-3:2011-04 Electromagnetic compatibility (EMC) Part 4-3: Testing and me

View lab

Siemens Healthineers AG Corporate

Erlangen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV # DIN EN 61000-4- 2:2009 Electromagnetic compatibility (EMC) Part 4-2: Testing and measu

View lab

BCS Automotive Interface Solutions

Radolfzell am Bodensee, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 2 KFZ Automotive EMV Grundnormen [Flex A] EMV ISO 11452-2 2019-01 Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic e

View lab

Bundesnetzagentur für Elektrizität, Gas, Telekommunikation, Post und Eisenbahnen Außenstelle Berlin, Messlabor Kolberg

Heidesee OT Kolberg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV DIN EN 61000-4-3: 2011-04 EMV Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektromagnetische Felder (IEC 61000-4-3:2006 + A1:2007 + A2:2010) EMV DIN EN 61000-4-4: 20

View lab

Siemens Aktiengesellschaft SIMATIC Type Test Karlsruhe

Karlsruhe, DE

We don't know yet whether this lab takes outside work.
Scope

Dem Prüflaboratorium ist, ohne dass es einer vorher igen Information und Zustimmung der DAkkS bedarf, die Anwendung der hier aufgeführten genormt en oder ihnen gleichzusetzenden Prüfverfahren mit unterschiedlichen Ausgabeständen gestattet

View lab

Schwille Elektronik Produktions- und Vertriebs

Kirchheim, DE

We don't know yet whether this lab takes outside work.
Scope

Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens 1 Prüfbereich / Einschränkungen 1 Grundnormen EMV DIN EN 61000 -4-2:2009 -12; VDE 0847-4-2:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil

View lab

EDAG Engineering GmbH ATC Fulda

Petersberg, DE

We don't know yet whether this lab takes outside work.
Scope

3. Elektromagnetische Verträglichkeit (EMV) am Standort B 3.1. Elektromagnetische Verträglichkeit (EMV) – Nicht flexibel akkreditierte Verfahren Norm / Verfahren Ausgabe Titel der Norm oder des Verfahrens Prüfbereich / Einschränkun

View lab

AUMOVIO Microelectronic GmbH EMV-Labor

Ingolstadt, DE

We don't know yet whether this lab takes outside work.
Scope

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical field Standard / in-house procedure / version Title of standard or in-house procedure Restriction 1 Basic

View lab

Vitesco Technologies GmbH EMC & Electrical Test Laboratory Regensburg

Regensburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2 2008-12 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV IEC 61000-4-4 Ed 3.0 2012-04 Electromagnetic compatibility (EMC) – Part 4-4: Tes

View lab

HENSOLDT Optronics GmbH Testzentrum

Oberkochen, DE

We don't know yet whether this lab takes outside work.
Scope

EMV am Standort Aalen Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung 1. Elektromagnetische Verträglichkeit 1.1. Grundnormen EMV DIN EN 61000 -4-2: 2009 EN 61000-4-2

View lab

AERA Consulting & Engineering Gesellschaft für Umweltmeßtechnik mbH

Mühlhausen, DE

We don't know yet whether this lab takes outside work.
Scope

3. Elektromagnetische Verträglichkeit (EMV) und elektrische Tests, Genormte oder ihnen gleichzusetzende Prüfverfahren [Flex A] Erprobung der El ektromagnetischen Verträglichkeit in Bezug auf die Funktionalität und Sicherheit elektronis

View lab

ABB

Lüdenscheid, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV IEC 61000 -4-2:2008 -12 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test EMV DIN EN 61000 -4-3: 2011-04 (VDE 0847-4-3)

View lab

Diehl Aerospace

Überlingen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2 (2008) Elektromagnetische Verträglichkeit (EMV) – Teil 4-2: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen die Entladung statischer Elektrizität Electromagnetic compatibility (EMC) – Part 4-2: Testing and m

View lab

HIMA Paul Hildebrandt GmbH Abteilung EDS, Team TLab

Brühl, DE

We don't know yet whether this lab takes outside work.
Scope

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Testing field Standard / in house procedure / Version Title of standard or in house procedure Test range / r

View lab

Siemens Aktiengesellschaft SIMATIC TYPE Test Amberg

Amberg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV IEC 61000 -4-4:2012 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test EMV DIN EN 61000 -4-4: 2013-04 VDE 0847-4

View lab

Keysight Technologies Deutschland GmbH Hardware Test Center Europe

Böblingen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test. EMV DIN EN IEC 61000-4- 3:2021 VDE 0847-4-3:2021 EN IEC 61000-4-3:2020 Elektromagnetische

View lab

Pilz GmbH & Co. KG

Ostfildern, DE

We don't know yet whether this lab takes outside work.
Scope

Bereich Norm/ Hausverfahren/ Version Titel der Norm Prüfbereich / Einschränkungen 1 Elektromagnetische Verträglichkeit (EMV) [Flex A] 1.1 Grundnormen EMV IEC 61000 -4-2:2008 -12 Electromagnetic compatibility (EMC) - Part 4-2: Te

View lab

Conti Temic microelectronic GmbH EMV

Ingolstadt, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2 2008-12 * Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Automotive Standard EMV ISO 10605 2008-07 * Cor1 2010-03 AMD1 2014-04 Road vehicles

View lab

DVGW-Forschungsstelle am Engler-Bunte-Institut des Karlsruher Instituts für Technologie (KIT) - Prüflaboratorium Gas -

Karlsruhe, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EN 61000 -4-2:2009 Elektromagnetische Verträglichkeit (EMV) – Teil 4-2: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen die Entladung statischer Elektrizität (IEC 6

View lab

DEUTA-WERKE

Bergisch Gladbach, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 Tischgeräte DIN EN 61000-4-3:2011 (EN 61000-4-3:2006 + A1:2008 + A2:2010) Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Stör

View lab

SCHÜCO International KG Technology Center

Bielefeld, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); German version EN 61000-4-2:2009 EN 61000-4-2:2009 DIN EN 61000-4-4 2013-04 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test

View lab

Vitesco Technologies AG & Co. KG EMC & Electrical Test Laboratory Regensburg

Regensburg, DE

We don't know yet whether this lab takes outside work.
Scope

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV IEC 61000 -3-12 Ed 2.1 2021-06 Electromagnetic compatibility (EMC) – Part 3-12: Limits - Limits for

View lab

Murrelektronik GmbH Prüfzentrum (4)

Oppenweiler, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN 61000-4-2:2001-12 VDE 0847-4-2:2001-12 Elektromagnetische Verträglichkeit (EMV) Prüf- und Messverfahren - Störfestigkeit gegen die Entladung statischer Elektrizit

View lab

duagon Germany

Nürnberg, DE

We don't know yet whether this lab takes outside work.
Scope

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV EVS-EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immu

View lab

OSRAM

Garching, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test DIN EN 61000-4-4:2005 (EN 61

View lab

BALLUFF

Neuhausen auf den Fildern, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009

View lab

HIMA Paul Hildebrandt GmbH Abteilung EDQ, Team HWS

Brühl, DE

We don't know yet whether this lab takes outside work.
Scope

This document is a translation. The definitive version is the original German annex to the accreditation certificate. Depart ment Standard / in house procedure / Version Title of standard or in house procedure Test area / reduct

View lab

SICK AG Corporate EMC Test Center

Waldkirch, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2025) EMV IEC 61000 -4-2:2025 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test EMV DIN EN IEC 61000 -4-3: 2021 Elektromagnetische Verträgl

View lab

Robert Bosch Gesellschaft mit beschränkter Haftung EMV-Prüflaboratorium, Abt. ME/EMC1

Schwieberdingen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2: 2008 (EN 61000-4-2) Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV IEC 61000-4-4: 2012 (EN 61000-4-4) Electromagnetic compatibility (E

View lab

TDK Electronics AG EMV-Labor

Regensburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2 (2008) Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test EMV DIN EN 61000-4-3 (2021) Elektromagnetische Verträglichkeit (EMV) – Teil 4-3: Prüf

View lab

Brose Fahrzeugteile SE & Co. Kommanditgesellschaft, Würzburg

Würzburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV IEC 61000-4-4 2012-04 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test (Adopted IEC 61000-4-4:2012, third edition, 2012-04

View lab

JUMO GmbH & Co. KG TestLab -

Fulda, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV DIN EN 61000 -4-4 VDE 0847-4-4:2013 (EN 61000-4-4:2012) Elektromagnetische Verträglichkeit (EMV) – Teil 4-4: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen schnelle transiente elektrische Störgr

View lab

K. A. Schmersal GmbH & Co. KG

Wuppertal, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008- 12 Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test DIN EN 61000-4- 2:2009-12 Teil 4-2: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen die Entladung statischer

View lab

AUMOVIO Germany

Regensburg, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008-12 Electromagnetic compatibi lity (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV ISO7637-1:2015-10 Road vehicles - Electrical di sturbances from conduction and coup

View lab

KNDS Deutschland GmbH & Co. KG Prüflabor EMV München / EMV-& Funkkompetenzzentrum

München, DE

We don't know yet whether this lab takes outside work.
Scope

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren / Einschränkungen 2 Fachgrundnormen EMV DIN EN 61000 -6-1; VDE 0839-6-1:2007 Elektromagnetische Verträglichkeit (EMV) - Teil

View lab

Aptiv Services Deutschland

Wiehl-Bomig, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2 / 2008-12 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test EMV IEC 61000-4-21 / 2011-01 Electromagnetic compatibility (EMC) – Part 4-21: Testin

View lab

Rheinmetall Landsysteme GmbH EMV-Prüfzentrum Unterlüß

Unterlüß, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN 61000-4-3; VDE 0847-4-3:2011-04 Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elekt

View lab

Bizerba SE & Co. KG

Balingen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008) EMV DIN EN IEC 61000 -4-3: 2021-11 (EN IEC 61000-4-3: 2020) Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity tes

View lab

Hanon Systems EFP Deutschland GmbH EMC Test Lab BHG

Bad Homburg v. d. Höhe, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2: 2008-12 Electromagnetic compatibility (EMC) – Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test Nur Table Top Equipment Keine VCP EMV IEC 62233:2005-10 Measurement methods for elect

View lab

KOLLMORGEN Europe

Ratingen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV EN 61000-4-4:2012 DIN EN 61000-4-4; VDE 0847-4-4:2013 Elektromagnetische Verträglichkeit (EMV) - Teil 4-4: Prüf- und Messverfahren - Prüfung der Störfestigkeit ge

View lab

Schaeffler Engineering

Werdohl, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN IEC 61000 -4-3; VDE 0847-4-3:2021 Elektromagnetische Verträglichkeit (EMV) – Teil 4-3: Prüf- und Messverfahren – Prüfung der Störfestigkeit gegen hochfrequente

View lab

KNDS Deutschland GmbH & Co. KG Prüflabor EMV Kassel / EMV-& Funk-Kompetenzzentrum

Kassel, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV DIN EN 61000-4-3; VDE 0847-4-3:2011 Elektromagnetische Verträglichkeit (EMV) - Teil 4-3: Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen hochfrequente elektrom

View lab

Flex Automotive

Frickenhausen, DE

We don't know yet whether this lab takes outside work.
Scope

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren / Einschränkungen 1 Grundnormen EMV DIN EN 61000 -4-2: 2009-12 Elektromagnetische Verträglichkeit (EMV) – Teil 4-2: Prüf- und

View lab

Siemens Aktiengesellschaft DI FA DSP SYS TT 2

Erlangen, DE

We don't know yet whether this lab takes outside work.
Scope

IEC 61000-4-2:2008); Deutsche Fassung EN 61000-4-2:2009 EMV IEC 61000 -4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test EMV DIN EN 61000 -4-3;

View lab

Materialprüfungsamt Nordrhein-Westfalen

Dortmund, DE

We don't know yet whether this lab takes outside work.
Scope

DIN EN 1158 2003-04 Berichtigung 1 2006-06 Schlösser und Baubeschläge - Schließfolgeregler - Anforderungen und Prüfverfahren DIN EN 1191 2013-04 Fenster und Türen – Dauerfunktionsprüfung - Prüfverfahren DIN EN 1628 2

View lab

Showing labs 51–100 of 107. Use pagination below to see more.

About ISO/IEC 17025 in Germany

Deutsche Akkreditierungsstelle (DAKKS) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Germany.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches