FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
ISO/IEC 17025 directory · Standard series

EN 61000 Accredited Testing Labs in Italy

EN 61000, all parts12 laboratories in Italy are accredited by ACCREDIA for at least one part of EN 61000. Each lab card shows which parts it holds. From the accredited scope text: “EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2014/AMD1:2017 Prove di immunità a scariche di elettricità statica/Electrostatic discharge immunity test CEI EN 61000-4-2:2011, EN 6” “EN 61000-6-4:2007/A1:2013, CEI EN 61000-6-4:2020, EN 61000-6-4:2007/A1:2011, EN IEC 61000-6-4:2019, IEC 61000-6-4:2006/A1:2010, IEC 61000-6-4:2018 CEI EN IEC 61000-6-2:2019, EN 61000-6-2:2005, EN 6100” “EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2006, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2005/COR1:2009, IEC 61000-4-5:2014/AMD1:2017 CEI EN 61000-4-2:2011, EN 61000-4-2:2009, IEC 61000-4-2:2008 Prove d” “EN 61000-4-12:2018, EN 61000-4-12:2017, IEC 61000-4-12:2017 CEI EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2014/AMD1:2017 CEI EN IEC 61000-4-3:2021, EN IEC 61000-4-3:2020, IEC”

Labs
10
Primary AB
ACCREDIA12 labs

Accredited Labs

TUV ITALIA

Volpiano, IT

HoldsPart 3-12Part 4-2Part 4-3Part 6-3
Scope

EN 61000-4-12:2018, EN 61000-4-12:2017, IEC 61000-4-12:2017 CEI EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2014/AMD1:2017 CEI EN IEC 61000-4-3:2021, EN IEC 61000-4-3:2020, IEC 61000-4-3:2020 CEI EN 61000-4-13:200

View lab

Intek S.p.a.

Rezzato, IT

HoldsPart 4-2Part 4-3Part 6-3
Scope

EN 61000-4-12:2017, IEC 61000-4-12:2017 Prova di immunità ad impulso/Surge immunity test (0,25 - 6 kV) EN 61000-4-5:2006, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2005/COR1:2009, IEC 61000-4-5:2014/AMD1:2017 Prove d'immunità ai campi el

View lab

Laboratorio EMC Sitael

Mola di Bari, IT

HoldsPart 4-2Part 4-3
Scope

EN 61000-4-5:2016/A1:2018, EN _ Prove d'immunità ai campi elettromagnetici irradiati a radiofrequenza/Radiated radio frequency electromagnetic field immunity test - solo/only da 80 MHz a 6 GHz Prove di immunità a scariche di elettricità

View lab

UL International Italia

Carugate, IT

HoldsPart 3-12Part 4-2Part 4-3Part 6-3
Scope

EN 61000-4-12:2017, IEC 61000-4-12:2017 Prova di immunità ad impulso/Surge immunity test (Limited to: 7 kV) Prove d'immunità ai campi elettromagnetici irradiati a radiofrequenza/Radiated radio frequency electromagnetic field immunity tes

View lab

PRS LAB srl Unipersonale - Sede di Faloppio

Faloppio, IT

HoldsPart 4-2
Scope

EN 61000-4-11:2006/A1:2018, CEI EN IEC 61000-4-11:2020, EN 61000-4-11:2004/A1:2017, EN IEC 61000-4-11:2020/AC:2020, EN IEC 61000-4-11:2020/AC:2020/AC:2022, IEC 61000-4-11:2004/AMD1:2017, IEC 61000-4-11:2020/COR1:2020, IEC 61000-4-11:2020/CO

View lab

CESI S.p.A.

Milano, IT

HoldsPart 4-2
Scope

EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2014/AMD1:2017 Prove di immunità a scariche di elettricità statica/Electrostatic discharge immunity test CEI EN 61000-4-2:2011, EN 61000-4-2:2009, IEC 61000-4-2:2008 Pro

View lab

Teslab

Livorno, IT

HoldsPart 4-2Part 4-3
Scope

EN 61000-4-9:2016, IEC 61000-4-9:2016 Disturbi condotti di modo comune nella gamma di frequenze da 0 Hz a 150 kHz/Conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz (Only DC Port) CEI EN 61000-4-16:2016, EN 61000-

View lab

Nemko S.p.A. a socio unico

Biassono, IT

HoldsPart 4-2Part 4-3Part 6-3
Scope

EN 61000-4-11:2006/A1:2018, CEI EN IEC 61000-4-11:2020, EN 61000-4-11:2004/A1:2017, EN IEC 61000-4-11:2020/AC:2020, EN IEC 61000-4-11:2020/AC:2020/AC:2022, IEC 61000-4-11:2004/AMD1:2017, IEC 61000-4-11:2020/COR1:2020, IEC 61000-4-11:2020/CO

View lab

White Lab S.r.l. - Test'ing

Falconara Marittima, IT

HoldsPart 4-2
Scope

EN 61000-4-5:2016/A1:2018, EN 61000-4-5:2006, EN 61000-4-5:2014/A1:2017, IEC 61000-4-5:2005/COR1:2009, IEC 61000-4-5:2014/AMD1:2017 CEI EN 61000-4-2:2011, EN 61000-4-2:2009, IEC 61000-4-2:2008 Prove di immunità ai transitori - raffiche di

View lab

TUV Rheinland Italia

Pogliano Milanese, IT

HoldsPart 4-2Part 4-3Part 6-3
Scope

EN 61000-4-12:2017, IEC 61000-4-12:2017 Prova di immunità ad impulso/Surge immunity test Prove d'immunità ai campi elettromagnetici irradiati a radiofrequenza/Radiated radio frequency electromagnetic field immunity test (80 MHz - 6 GHz,

View lab
Refine these results

This page is a fixed slice of the register: every EN 61000 scope we hold for Italy. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in Italy

Top analytes for EN 61000 in Italy

  • Harmonic Currents1

About ISO/IEC 17025 in Italy

Italian Accreditation Body (ACCREDIA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in Italy.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches