Japan
UL Japan
4383-326 Asama-cho, Ise-shi, Mie, 516-0021, Japan, Ise-shi, Mie, Japan
A2LA|5107.02ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Register record
- A2LACollected
- 5107.02Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active5107.02
Accredited scope, certificate 5107.02
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| electrical | ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013 | - | to 3 GHz |
| electrical | CISPR 12; EN 55012; AS/NZS CISPR 12; SANS 212; CISPR 25; EN 55025; EN/IEC 55025; ISO 10605; ISO 11452-2; ISO 7637-2; ISO 7637-3; ISO 11451-2; ISO 11451-4; ISO 11452-2; ISO 11452-3; ISO 11452-4; ISO 16750-2; ISO 13766-1; EN ISO 13766-1; ISO 13766-2; ISO 14982; EN ISO 13766-2; EN 14982; EN 12895; ICES-002; SANS 20010; ECE UN Regulation 10; ECE UN Regulation 97; ECE UN Regulation 116; ECE UN Regulation 161; ECE UN Regulation 162; ECE UN Regulation 163; IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2; SANS 61000-4-2 | - | 200 to 6 MHz – 1 GHz 180 V/m, 1 GHz – 2 GHz 200 V/m, 2 GHz |
| electrical | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 243000 MHz |
| electrical | IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3; IEC 61000-4-4; EN 61000-4-4; SANS 61000-4-4; IEC 61000-4-5; EN 61000-4-5; SANS 61000-4-5; IEC 61000-4-6; EN 61000-4-6; SANS 61000-4-6; IEC 61000-4-8; EN-61000-4-8; SANS 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; SANS 61000-4-11; IEC 60601-1-2 Edition 4.1 2020-09; IEC 60601-1-2 Edition 4.0 2014-02; IEC 60601-1-2 Edition 3.0 2007-03; EN 60601-1-2; SANS 60601-1-2; AS/NZS AS/NZS 4268; Canada (ISED) RSS-GEN; RSS-123; RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-193; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210; RSS-211; RSS-216; RSS-220; RSS-238; RSS-247 (with DFS); RSS-248; RSS-251; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-4; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 422-1; ETSI EN 300 422-2; ETSI EN 300 422-3; ETSI EN 300 440; ETSI EN 301 091-1; ETSI EN 301 091-2; ETSI EN 301 091-3; ETSI EN 301 357; ETSI EN 301 357-1; ETSI EN 301 357-2; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-33; ETSI EN 301 489-51; ETSI EN 301 489-52; ETSI EN 301 511; ETSI EN 301 893; ETSI EN 301 908-1; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3 | - | 8 to |
| electrical | - | - | - |
| electrical | ANSI C63.4; ANSI C63.10; ANSI C63.26; FCC OST/MP-5; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3; 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using FCC OST/MP-5:1986); CISPR 11; EN 55011; AS/NZS CISPR 11:2011; AS CISPR 11:2017; SANS 211; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; SANS 2332; CISPR 24; EN 55024; CISPR 35; EN 55035; SANS 2335; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; SANS 61000-6-2; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; SANS 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; SANS 61000-6-4; IEC 61000-6-8; EN IEC 61000-6-8; IEC 61131-2; EN 61131-2; SANS 61131-2; IEC 61326-1; EN 61326-1; EN IEC 61326-1; SANS 61326-1; IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6; ICES-001; ICES-003; EN 50130-4; EN 50498; VCCI-CISPR 32 | Medical equipment, electrical safety and EMC | - |
| - | ETSI EN 302 065-3-1; ETSI EN 302 208; ETSI EN 302 264; ETSI EN 302 264-1; ETSI EN 302 264-2; ETSI EN 302 567; ETSI EN 302 858; ETSI EN 302 858-1; ETSI EN 302 858-2; ETSI EN 303 396; ETSI EN 303 417; ETSI EN 303 413; ETSI EN 303 687; ETSI EN 303 851; ETSI EN 303 883; ETSI EN 304 220-1; ETSI EN 304 220-2; ETSI EN 305 550; ETSI EN 305 550-1; ETSI EN 305 550-2; 47 CFR, FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR, FCC Part 15, Subpart E (using ANSI C63.10:2013); 47 CFR, FCC Part 15, Subpart E (using FCC KDB 905462 D02 (V02)); 47 CFR, FCC Part 15, Subpart F (using ANSI C63.10:2013); 47 CFR, FCC Parts 2, 22, 24, 25, 27, 30, 73, 74, 90, 95, 96, 97, and 101 (using ANSI C63.26:2015, ANSI/TIA-102.CAAA-E, and ANSI/TIA-603-E); ANSI C63.10; ANSI C63.26; TIA-102.CAAA-D; ANSI/TIA-102.CAAA-E; ANSI/TIA-603-D; ANSI/TIA-603-E; FCC KDB 905462 D02 (V02); RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; RSS-102.IPD.MEAS; SPR-002; SPR-003; SPR-APD; EN 50360; EN 50361; EN 50364; EN 50383; EN 50566; EN 50663; EN 50664; EN 50665; IEC 62209-1; EN 62209-1; IEC 62209-2; IEC 62233; EN 62233; EN 62209-2; IEC 62311; EN 62311; EN IEC 62311; EN 62479; FCC KDB 865664 D01 and D02; FCC KDB 941225 D01, D05, D05A, D06, D07; FCC KDB 616217 D04; FCC KDB 447498; IEEE C95.1 (2005+A1:2010); IEEE C95.3 (2002); IEEE 1528:2013; ACA Standard (2014); AS/NZS 2772.2; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; IEC/IEEE 63195-1; EN IEC/IEEE 63195-1; RF:1; RF – PHY:1; RF – PHY:2; RF – PHY:3 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Japan
- UL Japan, Inc., Shonan EMCKanagawa · ~263 kmA2LAShares 3 accredited methods and materialsANSI C63.4:2014ANSI/TIA-603-EMedical equipment, electrical safety and EMC
- TUV SUD Japan Ltd. Yonezawa Testing Center (EMC Lab)Yamagata · ~534 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Cosmos CorporationMatsusaka-shi, Mie · ~20 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~263 kmA2LAShares 1 accredited test methodANSI C63.4
- Samoto & Associates,Yokohama, Kanagawa · ~285 kmA2LAShares 1 accredited test methodANSI C63.4
Accreditation data collected from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.