LACO Technologies
3085 West Directors Row, 84104, Salt Lake City, UT, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1530.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1530.01) Revised 02/06/2025 Page 2 of 2
II. Mechanical
Parameter/Equipment
Range (Torr)
CMC2, 4 (±)
Comments
Pressure (Calibration
of Vacuum Gauges)
(2 × 10-2) to 1000
(1 × 10-3) to (2 × 10-2)
(1 × 10-4) to (1 × 10-3)
(5 × 10-6) to (1 × 10-4)
(1 × 10-7) to (5 × 10-6)
1.0 %
2.0 %
5.1 %
7.1 %
8.0 %
Comparison method using
spinning rotor gauge,
high-accuracy ion gauge,
or capacitance manometer
_________________________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, the value is defined as the percentage of leak rate.
4 In the statement of CMC, the percent is defined as the percentage of reading.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Western States CalibrationSalt Lake City, UT · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Salt Lake CityDraper, UT · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sensor CalibrationsKaysville, UT · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DenverLongmont, CO · ~578 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- BHD Test & MeasurementThornton, CO · ~593 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.