Colorado Engineering Experiment Station,
54043 County Rd 37, 80648, Nunn, CO, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 5717.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017; ANSI/NCSL Z540-1-1994 | Water; Oil | See scope document |
| 2 | - | Natural GasShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5717.01) 10/29/2025 Page 2 of 2
Satellite Location
COLORADO ENGINEERING EXPERIMENT STATION, INC.
2365 240th Street,
Garner, IA 50438
John Reiner Phone: 970-897-2711
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Flow Meters4 –
Natural Gas
(42 to 900) acfh
(>900 to 40 000) acfh
(>40 000 to 60 000) acfh
(>60 000 to 90 000) acfh
(>90 000 to 250 000) acfh
(>250 000 to 1 100 000) acfh
(>1 100 000 to 1 330 000) acfh
0.24 %
0.23 %
0.21 %
0.19 %
0.18 %
0.16 %
0.17 %
Natural gas system
_______________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percen tages are percentages of reading.
4 Up to 9 flow standards can be placed in parallel to achieve required flow rate.
5 This accreditation covers calibrations performed at the main laboratory and the following satellite
laboratories listed above.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - DenverLongmont, CO · ~66 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- BHD Test & MeasurementThornton, CO · ~94 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - COLORADO SPRINGSColorado Springs, CO · ~208 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - Salt Lake CityDraper, UT · ~598 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western States CalibrationSalt Lake City, UT · ~599 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.