Registers refreshed 2026-11-20.See refresh dates
Sweden

RISE Research Institutes of Sweden

Argongatan 30, 431 53, Mölndal, Sweden

Visit website
SWEDAC A002626-100ISO/IEC 17025Register refreshed 2026-11-15

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
40
SWEDAC certificate
1
Sites in our directory
8
SWEDAC accredited scope

What this lab is accredited for

Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 40 standard numbers and the 32 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO24
ISO 139Textiles - Standard atmospheres for conditioning and testing
ISO 811Textiles - Determination of resistance to water penetration - Hydrostatic pressure test
ISO 1421Rubber- or plastics-coated fabrics - Determination of tensile strength and elongation at break
ISO 3071Textiles - Determination of pH of aqueous extract
ISO 3759Textiles - Preparation, marking and measuring of fabric specimens and garments in tests for determination of dimensional change
ISO 3801Textiles - Woven fabrics - Determination of mass per unit length and mass per unit area
ISO 4674-1Rubber- or plastics-coated fabrics - Determination of tear resistance - Part 1: Constant rate of tear methods
ISO 5077Textiles - Determination of dimensional change in washing and drying
ISO 6330Textiles - Domestic washing and drying procedures for textile testing
ISO 6941Textile fabrics - Burning behaviour - Measurement of flame spread properties of vertically oriented specimens
ISO 8191-1Furniture - Assessment of the ignitability of upholstered furniture - Part 1: Ignition source: smouldering cigarette
ISO 8191-2Furniture - Assessment of ignitability of upholstered furniture - Part 2: Ignition source: match-flame equivalent
Show all 24
ISO 9073-3Nonwovens - Test methods - Part 3: Determination of tensile strength and elongation at break using the strip method
ISO 9073-10Textiles - Test methods for nonwovens - Part 10: Lint and other particles generation in the dry state
ISO 11092Textiles - Physiological effects - Measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test)
ISO 12947-2Textiles - Determination of the abrasion resistance of fabrics by the Martindale method - Part 2: Determination of specimen breakdown
ISO 12952-1Textiles - Assessment of the ignitability of bedding items - Part 1: Ignition source: smouldering cigarette
ISO 12952-2Textiles - Assessment of the ignitability of bedding items - Part 2: Ignition source: match-flame equivalent
ISO 13934-1Textiles - Tensile properties of fabrics - Part 1: Determination of maximum force and elongation at maximum force using the strip method
ISO 13937-2Textiles - Tear properties of fabrics - Part 2: Determination of tear force of trouser-shaped test specimens (Single tear method)
ISO 13938-2Textiles - Bursting properties of fabrics - Part 2: Pneumatic method for determination of bursting strength and bursting distension
ISO 14184-1Textiles - Determination of formaldehyde - Part 1: Free and hydrolysed formaldehyde (water extraction method)
ISO 15025Protective clothing - Protection against flame - Method of test for limited flame spread
ISO 15797Textiles - Industrial washing and finishing procedures for testing of workwear
EN8
EN 597-1
EN 597-2
EN 1021-1
EN 1021-2
EN 1102
EN 1103
EN 12127
EN 20105
ISO 105 series8
ISO 105-A01Textiles - Tests for colour fastness - Part A01: General principles of testing
ISO 105-A02Textiles - Tests for colour fastness - Part A02: Grey scale for assessing change in colour
ISO 105-A03Textiles - Tests for colour fastness - Part A03: Grey scale for assessing staining
ISO 105-B02Textiles - Tests for colour fastness - Part B02: Colour fastness to artificial light: Xenon arc fading lamp test
ISO 105-C06Textiles - Tests for colour fastness - Part C06: Colour fastness to domestic and commercial laundering
ISO 105-E01Textiles - Tests for colour fastness - Part E01: Colour fastness to water
ISO 105-E04Textiles - Tests for colour fastness - Part E04: Colour fastness to perspiration
ISO 105-X12Textiles - Tests for colour fastness - Part X12: Colour fastness to rubbing

Read from the scope as published by SWEDAC. Register refreshed 2026-11-15.

Scope as published by SWEDAC

7 lines
SWEDAC

ISO/IEC 17025

Withdrawn

A002626-097

View on SWEDAC

Accredited scope, certificate A002626-097

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018 RISE Research Institutes of Sweden AB M; SS-EN ISO 14184-1 Formaldehyde Textiles Yes 2 No SS-EN ISO 3071 pH Textiles Yes 2 No Climate and environmental durability Method Parameter Technique Measure Material Flex Type of flex Field Note ISO 105-A02 Color fastness Textiles Yes 2 No ISO 3801 Mass per unit Textiles Yes 2 No Metod 5/Method 5 SS-EN 12127 Mass per unit Textiles Yes 2 No SS-EN 20105 A02 Color fastness Textiles Yes 2 No SS-EN 20105 A03 Color fastness Textiles Yes 2 No SS-EN ISO 105-A01 Color fastness Textiles Yes 2 No Page 1; ISO/IEC 17025:2018 RISE Research Institutes of Sweden AB Mölndal Accreditation number 1002; ISO 14184-1 Formaldehyde Textiles Yes 2 No SS-EN ISO 3071 pH Textiles Yes 2 No Climate and environmental durability Method Parameter Technique Measure Material Flex Type of flex Field Note ISO 105-A02 Color fastness Textiles Yes 2 No ISO 3801 Mass per unit Textiles Yes 2 No Metod 5/Method 5 SS-EN 12127 Mass per unit Textiles Yes 2 No SS-EN 20105 A02 Color fastness Textiles Yes 2 No SS-EN 20105 A03 Color fastness Textiles Yes 2 No SS-EN ISO 105-A01 Color fastness Textiles Yes 2 No Page 1Textile10 to 1000 mg/kg
2SS-EN ISO 105-A03 Color fastness Textiles Yes 2 No SS-EN ISO 105-B02 Color fastness Textiles Yes 2 No SS-EN ISO 105-C06 Color fastness Textiles Yes 2 No SS-EN ISO 105-E01 Color fastness Textiles Yes 2 No SS-EN ISO 105-E04 Color fastness Textiles Yes 2 No SS-EN ISO 105-X12 Color fastness Textiles Yes 2 No SS-EN ISO 11092 Thermal and water-vapour resistance Textiles Yes 2 No SS-EN ISO 12947-2 Abrasion resistance Textiles Yes 2 No SS-EN ISO 139/A1 Textiles Yes 2 No Standardatmosf; SS-EN ISO 13934-1 Tensile Testing CRE-machine Textiles Yes 2 No SS-EN ISO 13937-2 Tear resistance CRE-machine Textiles Yes 2 No SS-EN ISO 13938-2 Bursting strength Textiles Yes 2 No SS-EN ISO 1421 Tensile Testing CRE-machine Textiles Yes 2 No SS-EN ISO 15797/AC Cleanability Textiles Yes 2 No Industritv; SS-EN ISO 3759 Dimensional change Textiles Yes 2 No SS-EN ISO 4674-1 Tear resistance CRE-machine Textiles Yes 2 No SS-EN ISO 5077 Dimensional change Textiles Yes 2 No SS-EN ISO 6330 Cleanability Textiles Yes 2 No Hush; SS-EN ISO 811 Water tightness Textiles Yes 2 No SS-EN ISO 9073-10 Linting Particle counter Textiles Yes 2 No Page 2; ISO 105-A03 Color fastness Textiles Yes 2 No SS-EN ISO 105-B02 Color fastness Textiles Yes 2 No SS-EN ISO 105-C06 Color fastness Textiles Yes 2 No SS-EN ISO 105-E01 Color fastness Textiles Yes 2 No SS-EN ISO 105-E04 Color fastness Textiles Yes 2 No SS-EN ISO 105-X12 Color fastness Textiles Yes 2 No SS-EN ISO 11092 Thermal and water-vapour resistance Textiles Yes 2 No SS-EN ISO 12947-2 Abrasion resistance Textiles Yes 2 No SS-EN ISO 139/A1 Textiles Yes 2 No Standardatmosfärer/Standard atmospheres SS-EN ISO 13934-1 Tensile Testing CRE-machine Textiles Yes 2 No SS-EN ISO 13937-2 Tear resistance CRE-machine Textiles Yes 2 No SS-EN ISO 13938-2 Bursting strength Textiles Yes 2 No SS-EN ISO 1421 Tensile Testing CRE-machine Textiles Yes 2 No SS-EN ISO 15797/AC Cleanability Textiles Yes 2Textile-
3SS-EN 1021-1 Ignitability Furniture Yes 2 No SS-EN 1021-2 Ignitability Furniture Yes 2 No SS-EN 1102 Flame spread Textiles Yes 2 No SS-EN 1103 Flame spread Textiles Yes 2 No SS-EN 597-1 Ignitability Furniture Yes 2 No SS-EN 597-2 Ignitability Furniture Yes 2 No SS-EN ISO 12952-1 Ignitability Textiles Yes 2 No SS-EN ISO 12952-2 Ignitability Textiles Yes 2 No SS-EN ISO 15025 Flame spread Protective clothing Yes 2 No SS-EN ISO 6941 Flame spread Textiles Yes 2 No Changes in the scope of accreditation are in bold; ISO 8191-1 Ignitability Furniture Yes 2 No ISO 8191-2 Ignitability Furniture Yes 2 No SS-EN 1021-1 Ignitability Furniture Yes 2 No SS-EN 1021-2 Ignitability Furniture Yes 2 No SS-EN 1102 Flame spread Textiles Yes 2 No SS-EN 1103 Flame spread Textiles Yes 2 No SS-EN 597-1 Ignitability Furniture Yes 2 No SS-EN 597-2 Ignitability Furniture Yes 2 No SS-EN ISO 12952-1 Ignitability Textiles Yes 2 No SS-EN ISO 12952-2 Ignitability Textiles Yes 2 No SS-EN ISO 15025 Flame spread Protective clothing Yes 2 No SS-EN ISO 6941 Flame spread Textiles Yes 2Textile-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

SWEDAC

ISO/IEC 17025

Active

A002626-100

View on SWEDAC

Accredited scope, certificate A002626-100

LineMethodMatrixRange
1ISO 8191-1; ISO 8191-2; SS-EN 1021-1; SS-EN 1021-2; SS-EN 1102; SS-EN 1103; SS-EN 597-1; SS-EN 597-2; SS-EN ISO 12952-1; SS-EN ISO 12952-2; SS-EN ISO 15025; SS-EN ISO 6941; SS-EN ISO/IEC 17025:2018Textile-
2Intern metod; SWEREA IVF-metod 81-10; CPSC-CH-E1001-08.3; CPSC-CH-E1002-08.3; CPSC-CH-E1003-09.1; SS-EN ISO 14184-1; SS-EN ISO 3071; ISO 105-A02; ISO 3801; Metod 5/Method 5; SS-EN 12127; SS-EN 20105 A02; SS-EN 20105 A03; SS-EN ISO 105-A01; SS-EN ISO 105-A03; SS-EN ISO 105-B02Textile10 to 1000 mg/kg
3SS-EN ISO 105-C06; SS-EN ISO 105-E01; SS-EN ISO 105-E04; SS-EN ISO 105-X12; SS-EN ISO 11092; SS-EN ISO 12947-2; SS-EN ISO 139/A1; SS-EN ISO 13934-1; SS-EN ISO 13937-2; SS-EN ISO 13938-2; SS-EN ISO 1421; SS-EN ISO 15797/AC; SS-EN ISO 3759; SS-EN ISO 4674-1; SS-EN ISO 5077; SS-EN ISO 6330; SS-EN ISO 811; SS-EN ISO 9073-10; SS-EN ISO 9073-3Textile-
4

Extracted from the scope document; tables may not line up. View scope for the original.

Bilaga 1 Beteckning Datum 2026-01-16 2025/2702 Ackrediteringens omfattning är flexibel enligt vad som anges i detta beslut. Det ackrediterade organet skall alltid kunna tillhandhålla en uppdaterad lista över den aktuella omfattningen för sin ackreditering. Förändrade omfattningsrader är markerade med fetstil. Typ av flexibilitet 1 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod. 2 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod - Införa ny version och modifieringar av icke-standardiserad metod. Förfarandet ska vara likvärdigt - Införa ny parameter/komponent/undersökning - Införa nytt mätområde - Införa nytt material/nya produkter/matriser - Införa ny metod som är likvärdig med metoder som redan finns i ackrediteringsbeslutet Sida 4 (4)

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Argongatan 30, Mölndal, 431 53, SE

57.64246, 12.00641

Open in Maps

Other Locations

7 other sites in this organization

Accreditation data refreshed from the SWEDAC register on .