GE Healthcare
3000 North Grandview Blvd, 53188, Waukesha, WI, United States
Visit website- Accredited standards
- 12
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series10
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion
Limits written next to it
IEC 61000-4-8 (excluding short duration mode)
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity testSome clauses
Limits written next to it
Radiated Fields in Close Proximity IEC 61000-4-39 (clause 6.1.2 and 6.1.3 only)
Other standards2
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
CISPR 11; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-4-39; IEC 60601-1-2 Edition 3.0 (2007); IEC 60601-1-2 Edition 4.0 (2014); IEC 60601-1-2 Edition 4.1 (2020)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active2593.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 2593.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CISPR 11; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC 61000-4-39; IEC 60601-1-2 Edition 3.0 (2007); IEC 60601-1-2 Edition 4.0 (2014); IEC 60601-1-2 Edition 4.1 (2020) | - | to 6 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2593.01) Revised 01/13/2026 Page 2 of 2
1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the
version that immediately precedes the current version for a period of one year from the date of publication of
the standard test method, per Annex A, Part C of A2LA R101 - General Requirements: Accreditation of
Conformity Assessment Bodies.
2 The laboratory is only accredited for testing activities outlined within the test methods listed above.
Reference to any other activity within these standards, such as risk management or risk assessment, does not
fall within the laboratory’s accredited capabilities. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
GE HEALTHCARE
Waukesha, WI
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of July 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2593.01
Valid to August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- International ComplianceNeenah, WI · ~126 kmA2LAShares 1 accredited test methodCISPR 11
- TUV SUD AmericaNew Brighton, MN · ~450 kmA2LAShares 1 accredited test methodCISPR 11
- Intertek Testing Services NAFridley, MN · ~455 kmA2LAShares 1 accredited test methodCISPR 11
- Nebraska Center for Excellence in ElectronicsLincoln, NE · ~738 kmA2LAShares 1 accredited test methodCISPR 11
- TUV SUD AmericaAlpharetta, GA · ~1,058 kmA2LAShares 1 accredited test methodCISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.