International Compliance
1057 Tullar Court, 54956, Neenah, WI, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at International Compliance?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2599.01Active
Certificates and scope
1ISO/IEC 17025
Active2599.01
The scope document we hold says it was valid until 2026-04-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 2599.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | CFR 47 FCC, Part 15B (using ANSI C63.4:2014) and Part 15C (using ANSI C63.10:2013); CFR 47 FCC, Part 18 (using MP-5:1986); CISPR 11; EN 55011; CISPR 14-1; EN 55014-1; CISPR 15; EN 55015; CISPR 22; CISPR 32; EN 55022; EN 55032; ICES-001; ICES-003; IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-3; EN 61000-3-3; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-5; IEC 61000-1-3:2005; IEC 61000-4-6; IEC 61000-4-6:2008; IEC 61000-4-8; IEC 61000-4-11 | - | to 26 GHz |
| 2 | electrical | IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-3; EN 61000-6-3; IEC 61000-6-4; EN 61000-6-4; IEC 61326-1; EN 61326-1; IEC 60601-1-2:2001; IEC 60601-1-2:2007; IEC 60601-1-2; CISPR 24; EN 55024; CISPR 14-2; EN 55014-2; RSS-GEN; RSS-210; CISPR 25; SAE J1113-41; SAE J1113-4; ISO 11452-4; SAE J1113-13; ISO 10605; SAE J1113-21; ISO 11452-2; SAE J1113-11; ISO 7637-2; ISO 16750-2; EG-812-22614; E/ECE/324 Addendum 9: Regulation 10 | - | to 26 GHz |
| 3 | electrical | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013 | - | to 26000 MHz |
| 4 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- TUV SUD AmericaNew Brighton, MN · ~388 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Intertek Testing Services NAFridley, MN · ~392 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- Core Compliance Testing ServicesHudson, NH · ~1,380 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- TUV Rheinland of North AmericaBoxborough, MA · ~1,381 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
- ElectroMagnetic InvestigationsHillsboro, OR · ~2,705 kmA2LAShares 2 accredited test methodsANSI C63.4:2014CISPR 11
Accreditation data refreshed from the A2LA register on .