Thermetrics
4220 24th Avenue West, 98199, Seattle, WA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3984.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 25.4 mm |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3984.01) 6/24/2024 Page 2 of 3
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Voltage – Measure
Up to 0.1 V
(0.1 to 0.9999) V
(1 to 9.9999) V
(10 to 60) V
0.000 012 V
0.000 30 V
0.000 69 V
0.016 V
Agilent 34401A
DC Voltage – Measure3
(10 to 60) V
0.019 V
Keysight U2741A
DC Voltage – Generate
Up to 11 V
0.000 45 V
Ectron 1140A
Electrical Simulation of
Thermocouples3 –
Type J
Type K
Type T
Up to 200 °C
Up to 200 °C
Up to 200 °C
0.13 °C
0.12 °C
0.10 °C
Ectron 1140A
III. Mechanical
Parameter/Equipment
Range CMC2, 6 (±) Comments
Mass – Measure
Up to 100 g
(100 to 2000) g
0.018 g
0.35 g
Cole-Parmer 20000-32
& EJ-2000
Mass – Measure3
Up to 400 g
0.37 g
Ohaus SP 401 | to 0.1 V |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3984.01) 6/24/2024 Page 3 of 3
IV. Thermodynamics
Parameter/Equipment
Range CMC2, 6 (±) Comments
Temperature – Measure
Up to 60 °C
0.012 °C
Fluke 1504 & Fluke
5641
Temperature – Measure3
(15 to 40) °C
0.021 °C
Thermetrics
temperature calibrator
516- XX
_______________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for these calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | to 60 °C |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Global Calibration ServicesTukwila, WA · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cascade Engineering ServicesRedmond, WA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Eustis Co., Inc./Pyrocom CalibrationLynnwood, WA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Robb Precision Tool ServicesLynnwood, WA · ~25 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.