Registers refreshed 2026-11-20.See refresh dates
United States

Cascade Engineering Services

6640 185th Ave NE, 98052, Redmond, WA, United States

Visit website
A2LA 2560.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 2560.01 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 2 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Thread Plug Gages – English & Metric, 60° Pitch Diameter, (8 to 80) TPI – Major Diameter Pitch Diameter (0.06 to 4) in (0.05 to 2.5) in (>2.5 to 4) in (10 + 5.5L) µin 140 µin 150 µin P&W Labmaster TM, gage blocks, thread wires Cylindrical Plug Gages & Thread Wires Up to 7 in (10 + 5.5L) µin P&W LabmasterTM, gage blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Generate (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1000) V 9.9 µV/V + 0.40 µV 5.8 µV/V + 0.70 µV 4.0 µV/V + 2.5 µV 4.0 µV/V + 4.0 µV 5.8 µV/V + 40 µV 7.5 µV/V + 0.40 mV Fluke 5720A DC Voltage3 – Measure (0 to 100) mV (100 to 200) mV 200 mV to 1 V (1 to 2) V (2 to 10) V (10 to 20) V (20 to 200) V (200 to 1000) V (0 to 10) kV 26 µV/V + 0.30 µV 6.9 µV/V + 0.10 µV 9.9 µV/V + 0.30 µV 3.5 µV/V + 0.40 µV 9.6 µV/V + 0.50 µV 3.5 µV/V + 4.0 µV 5.2 µV/V + 40 µV 5.2 µV/V + 0.05 mV 0.04 % + 30 mV HP 3458A Fluke 8508A Vitrek 4700
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 3 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current3 – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11.0) A (11 to 20) A 46 µA/A + 6.0 nA 40 µA/A + 7.0 nA 40 µA/A + 40 nA 63 µA/A + 0.70 µA 150 µA/A + 12 µA 420 µA/A + 0.48 mA 0.12 % + 0.75 mA* Fluke 5720A Fluke 5720A & 5725A Fluke 5520A-SC1100 *floor after 30 s DC Current3 – Measure (0 to 0.1) µA (0.1 to 1) µA (1 to 10) µA (10 to 200) µA (0.2 to 2) mA (10 to 20) mA (20 to 200) mA 200 mA to 1 A (1 to 2) A (2 to 20) A 0.15 % + 40 pA 91 µA/A + 40 pA 55 µA/A + 0.10 nA 18 µA/A + 0.40 nA 14 µA/A + 4.0 nA 15 µA/A + 40 nA 42 µA/A + 0.80 µA 180 µA/A + 10 µA 200 µA/A + 16 µA 440 µA/A + 0.4 mA HP 3458A, Fluke 8508A Resistance3 – Generate, Fixed Points 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 59 µΩ 110 µΩ 210 µΩ 270 µΩ 510 µΩ 1.2 mΩ 2.2 mΩ 9.8 mΩ 19 mΩ 98 mΩ 190 mΩ 1.3 Ω 2.4 Ω 23 Ω 46 Ω 460 Ω 1.0 kΩ 12 kΩ Fluke 5720A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 4 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ (0.0 to 0.01) Ω 18 µΩ/Ω + 4 µΩ 11 µΩ/Ω + 14 µΩ 9.9 µΩ/Ω + 50 µΩ 9.9 µΩ/Ω + 0.5 mΩ 9.9 µΩ/Ω + 5 mΩ 9.9 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1 Ω 18 µΩ/Ω + 10 Ω 69 µΩ/Ω + 1 kΩ 170 µΩ/Ω + 100 kΩ 610 µΩ/Ω + 10 MΩ 250 µΩ/Ω + 0.06 µΩ Fluke 8508A Fluke 5720, Fluke 8508A Parameter/Range Frequency CMC2, 5 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4000 to 1.0999) nF (1.1000 to 3.2999) nF (3.3000 to 10.9999) nF (11.0000 to 109.999) nF (110.000 to 329.999) nF (0.330 00 to 1.099 99) µF (1.100 00 to 3.299 99) µF (3.3000 to 10.9999) µF (11.0000 to 32.9999) µF (33.000 to 109.999) µF (110.000 to 329.999) µF (0.330 00 to 1.099 99) mF (1.100 00 to 3.299 99) mF (3.3000 to 10.9999) mF (11.0000 to 32.9999) mF (33.00 to 110.00) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.85 % + 0.010 nF 0.62 % + 0.010 nF 0.59 % + 0.010 nF 0.30 % + 0.010 nF 0.30 % + 0.10 nF 0.30 % + 0.30 nF 0.29 % + 1.0 nF 0.30 % + 3.0 nF 0.30 % + 10 nF 0.47 % + 30 nF 0.53 % + 0.10 µF 0.53 % + 0.30 µF 0.53 % + 1.0 µF 0.52 % + 3.0 µF 0.52 % + 10 µF 0.87 % + 30 µF 1.3 % + 0.10 mF Fluke 5520A- SC1100
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 5 of 16 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Capacitance – Measure @ 1 kHz Up to 10 pF (10 to 100) pF (100 to 400) pF (400 to 1600) pF (1600 to 6400) pF 6400 pF to 25 nF (25 to 100) nF (100 to 400) nF (400 to 1600) nF 1600 nF to 6 µF (6 to 25) µF (25 to 100) µF (100 to 1000) µF 0.48 % 0.06 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.06 % 0.48 % GenRad 1689-9700 Oscilloscopes3 – Amplitude DC Signal 50 Ω Load 1 MΩ Load Leveled Sine Flatness 50 kHz Reference Time Marker 50 Ω Load Rise Time (0 to ± 6.6) V (0 to ± 130) V 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 1 ns to 20 ms 50 ms to 5 s ≤2 MHz >2 MHz 0.28 % + 40 µV 0.057 % + 40 µV 1.9 % + 0.10 mV 2.4 % + 0.10 mV 4.6 % + 0.10 mV 5.7 % + 0.10 mV 2.8 µs/s (29 + 1000t) µs/s 300 ps 350 ps Fluke 5520-SC1100 t = time interval (s)
to 1000 µF
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 6 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple3 – Generate Type E Type J Type K Type T (-250 to -100) °C (-100 to -25.0) °C (-25.0 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30.0) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0.0) °C (0.0 to 120) °C (120 to 400) °C 0.60 °C 0.19 °C 0.60 °C 0.19 °C 0.25 °C 0.32 °C 0.19 °C 0.30 °C 0.20 °C 0.27 °C 0.39 °C 0.21 °C 0.27 °C 0.31 °C 0.48 °C 0.75 °C 0.29 °C 0.27 °C 0.17 °C Fluke 5520- SC1100 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (0 to 2.2) mV (2.2 to 22) mV (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz 280 µV/V + 4.0 µV 100 µV/V + 4.0 µV 240 µV/V + 4.0 µV 580 µV/V + 5.0 µV 0.16 % + 20 µV 0.31 % + 20 µV 280 µV/V + 4.0 µV 100 µV/V + 4.0 µV 240 µV/V + 4.0 µV 580 µV/V + 5.0 µV 0.16 % + 20 µV 0.31 % + 20 µV Fluke 5720A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (cont) (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (220 to 1100) V (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (15 to 50) Hz 50 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 280 µV/V + 12 µV 100 µV/V + 7.0 µV 240 µV/V + 7.0 µV 530 µV/V + 17 µV 0.16 % + 25 µV 0.31 % + 45 µV 280 µV/V + 40 µV 100 µV/V + 15 µV 110 µV/V + 10 µV 140 µV/V + 30 µV 0.12 % + 0.20 mV 0.20 % + 0.30 mV 280 µV/V + 0.40 mV 100 µV/V + 0.15 mV 110 µV/V + 0.10 mV 130 µV/V + 0.20 mV 0.12 % + 2.0 mV 0.17 % + 3.2 mV 280 µV/V + 4.0 mV 100 µV/V + 1.5 mV 110 µV/V + 1 mV 180 µV/V + 2.5 mV 350 µV/V + 16 mV 81 µV/V + 3.5 mV 200 µV/V + 6.0 mV 700 µV/V + 11 mV 700 µV/V + 11 mV 0.27 % + 45 mV Fluke 5720A With Fluke 5725A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (0 to 10) mV (10 to 100) mV (10 to 200) mV 100 mV to 1 V 100 mV to 2 V (1 to 10) V (2 to 20) V (10 to 20) Hz (20 to 40) Hz (40 to 100) Hz 100 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (1 to 2) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 2) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.48 % + 3.0 µV 0.18 % + 3.0 µV 0.08 % + 1.1 µV 0.043 % + 1.1 µV 0.18 % + 1.1 µV 0.84 % + 1.1 µV 4.8 % + 2.0 µV 2.4 % + 10 µV 3.6 % + 10 µV 6.0 % + 10 µV 12 % + 10 µV 180 µV/V + 14 µV 150 µV/V + 4 µV 130 µV/V + 4 µV 120 µV/V + 2 µV 120 µV/V + 4 µV 350 µV/V + 8 µV 810 µV/V + 20 µV 12 % + 0.10 mV 160 µV/V + 120 µV 120 µV/V + 20 µV 98 µV/V + 20 µV 75 µV/V + 20 µV 98 µV/V + 20 µV 240 µV/V + 40 µV 580 µV/V + 200 µV 0.35 % + 2 mV 1.2 % + 20 mV 12 % + 1.0 mV 160 µV/V + 1.2 mV 120 µV/V + 0.20 mV 98 µV/V + 0.20 mV 75 µV/V + 0.20 mV 98 µV/V + 0.20 mV 240 µV/V + 0.40 mV 580 µV/V + 2.0 mV 0.35 % + 20 mV 1.2 % + 0.20 V HP 3458A Fluke 8508A HP 3458A Fluke 8508A HP 3458A Fluke 8508A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 9 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (cont) (20 to 200) V (200 to 1000) V (0 to 7) kV (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (50 to 60) Hz 160 µV/V + 12 mV 120 µV/V + 2.0 mV 98 µV/V + 2.0 mV 75 µV/V + 2.0 mV 98 µV/V + 2.0 mV 240 µV/V + 4.0 mV 580 µV/V + 20 mV 0.35 % + 200 mV 1.2 % + 2.0 V 160 µV/V + 70 mV 130 µV/V + 20 mV 110 µV/V + 20 mV 240 µV/V + 40 mV 590 µV/V + 0.20 V 0.15 % + 0.10 V Fluke 8508A Vitrek 4700 AC Current3 – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.16 % + 16 nA 0.15 % + 10 nA 0.10 % + 8.0 nA 0.33 % + 12 nA 0.73 % + 65 nA 0.099 % + 40 nA 0.088 % + 35 nA 0.072 % + 35 nA 0.31 % + 0.11 µA 0.71 % + 0.65 µA 0.093 % + 0.40 µA 0.081 % + 0.35 µA 0.072 % + 0.35 µA 0.31 % + 0.55 µA 0.71 % + 5.0 µA Fluke 5720A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 10 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (cont) (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (40 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.092 % + 4.0 µA 0.081 % + 3.5 µA 0.078 % + 2.5 µA 0.32 % + 3.5 µA 0.71 % + 10 µA 0.61 % + 35 µA 0.40 % + 80 µA 2.0 % + 1.6 mA 0.11 % + 0.17 mA 0.25 % + 0.38 mA 1.0 % + 0.75 mA 0.19 % + 5.9 mA 0.21 % + 5.9 mA 3.7 % + 5.9 mA Fluke 5720A Fluke 5720A With Fluke 5725A Fluke 5520A-SC1100 AC Current3 – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 100) mA (20 to 200) mA (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (30 to 50) kHz (50 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 550 µA/A + 20 nA 550 µA/A + 20 nA 750 µA/A + 20 nA 0.46 % + 20 nA 330 µA/A + 0.20 µA 320 µA/A + 0.20 µA 750 µA/A + 0.20 µA 0.46 % + 0.20 µA 330 µA/A + 2.0 µA 320 µA/A + 2.0 µA 750 µA/A + 2.0 µA 0.46 % + 2.0 µA 0.48 % + 20 µA 0.48 % + 20 µA 330 µA/A + 20 µA 290 µA/A + 20 µA 690 µA/A + 20 µA Fluke 8508A HP 3458A, option II Fluke 8508A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 11 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Measure (cont) 100 mA to 1 A 200 mA to 2 A (2 to 20) A (20 to 100) A (100 to 200) A (200 to 1200) A (30 to 50) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (30 to 1000) Hz (30 to 1000) Hz (30 to 1000) Hz 1.2 % + 0.40 mA 690 µA/A + 0.20 mA 820 µA/A + 0.20 mA 0.35 % + 0.20 mA 920 µA/A + 2.0 mA 0.29 % + 2.0 mA 0.58 % + 20 mA 0.35 % + 20 mA 0.36 % + 200 mA HP 3458A, option II Fluke 8508A Fluke 8508A with AEMC SR704 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Low Resistance (Earth Resistance) 3 – Generate 100 mΩ to 4.99 Ω (5 to 29.9) Ω (30 to 199.9) Ω (200 to 499) Ω 500 Ω to 1.999 kΩ (2 to 4.99) kΩ (5 to 10) kΩ 0.012 Ω + 0.4 % 0.016 Ω + 0.23 % 0.057 Ω + 0.22 % 0.31 Ω + 0.23 % 0.57 Ω + 0.21 % 0.49 % 14 Ω + 0.16 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD High Resistance (Insulation Resistance) 3 – Generate (10 to 39.99) kΩ (40 to 99.99) kΩ (100 to 199.99) kΩ (200 to 999.99) kΩ (1 to 9.999) MΩ (10 to 999.9) MΩ (1 to 10) GΩ 100 GΩ 47 Ω + 0.16 % 23 Ω + 0.22 % 11 Ω + 0.23 % 8.6 Ω + 0.23 % 1.8 Ω + 0.35 % 2.9 Ω + 0.6 % 1.1 MΩ + 1.2 % 3.5 GΩ Fluke 5320A, HVA, 80k-40 & 5320A- LOAD High Resistance (Insulation Resistance)3 – Source with R Multiplier (0.35 to 99.99) GΩ (100 to 999.9) GΩ (1 to 10) TΩ 2.6 MΩ + 2 % 6.3 kΩ + 2.9 % 4.9 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Ground Bond Resistance3 – Decade Source, Fixed Points 25 mΩ 50 mΩ 100 mΩ 330 mΩ 500 mΩ 1 Ω 1.8 Ω 5 Ω 10 Ω 18 Ω 50 Ω 100 Ω 180 Ω 500 Ω 1 kΩ 1.8 kΩ 6 mΩ 6.2 mΩ 6.7 mΩ 10 mΩ 12 mΩ 0.014 Ω 0.022 Ω 0.037 Ω 0.1 Ω 0.21 Ω 0.43 Ω 0.82 Ω 1.5 Ω 3.4 Ω 6.3 Ω 30 Ω Fluke 5320A, HVA, 80k-40 & 5320A- LOAD Leakage Current3 – Generate Passive/Differential Active (0.1 to 30) mA (0.1 to 30) mA 2.6 µA + 0.46 % 3.1 µA + 0.45 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD Residual Current Device3 – Trip Current Trip Time Range (3 to 3000) mA (10 to 5000) ms 1.2 % 0.29 ms + 0.024 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD AC/DC Multimeter3 – DC, 20 Hz to 2 kHz (1 to 10) V (10 to 100) V (100 to 1100) V 6 mV + 0.18 % 59 mV + 0.23 % 0.64 V + 0.24 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD AC/DC Multimeter3 – DC, 20 Hz to 400 Hz (30 to 300) mA 300 mA to 3 A (3 to 30) A 0.1 mA + 0.26 % 1.8 mA + 0.18 % 18 mA + 0.35 % Fluke 5320A, HVA, 80k-40 & 5320A- LOAD
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 13 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments AC/DC Current3 – Hipot Leakage Current Measurement DC, 20 Hz to 2 kHz (30 to 300) µA 300 µA to 3 mA (3 to 30) mA (30 to 300) mA 0.15 µA + 0.79 % 2.1 µA + 0.24 % 17 µA + 0.24 % 0.19 mA + 0.23 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD DC Voltage Calibrator3 (3 to 30) V (30 to 150) V (150 to 600) V 0.01 V + 0.13 % 0.034 V + 0.13 % 0.23 V + 0.12 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD AC Voltage Calibrator3 – (40 to 400) Hz (3 to 30) V (30 to 100) V (100 to 300) V (300 to 600) V 0.01 V + 0.14 % 0.022 V + 0.17 % 0.13 V + 0.12 % 0.26 V + 0.11 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD Frequency Calibrator3 (40 to 400) Hz 0.0062 Hz + 0.06 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD DC Voltage3 – High Resistance Decade 2000 V Range <1 MΩ >1 MΩ 2.4 V + 1.3 % 5.7 V + 1.3 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD Test Current – Measure3 AC + DC rms (0 to 400) mA 0.36 mA + 10 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD DC High Voltage – Measure3 (5320A with 10 kV Adapter) (5320A with HV Probe) (>10 to 40) kV 0.012 kV + 0.62 % Fluke 5320A, HVA, 80k- 40 & 5320A-LOAD
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 14 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments AC High Voltage – Measure3 (50 to 60) Hz (5320A with HV Probe) (>10 to 40) kV 0.016 kV + 0.62 % Fluke 5320A, HVA, 80k-40 & 5320A-LOAD III. Electrical – RF/Microwave Parameter/Range Frequency CMC 2, 5 (±) Comments Total Harmonic Distortion – Measure 3 Hz to 3 GHz 0.49 dB Keysight E4440A IV. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Scales & Balances3 (1 to 500) mg (1 to 600) g 200 g to 20 kg (1/32 to 64) oz (0.5 to 50) lb (0.5 to 1000) lb 0.73 % + 0.6R (260 + 2M) µg + 0.6R 22 µg/g + 0.6R 0.17 % + 0.6R 0.04 % + 0.6R 0.16 lb + 0.6R Class 0 weights Class 0 weights Class 2 weights Class F weights Class F weights Class F weights Pressure3 – Measure/Measuring Equipment (0 to 50) psia (-14.5 to 500) psig (0 to 1500) psig (1500 to 4000) psig 0.032 psi 0.24 psi 0.23 psi + 0.004 % 0.04 psi + 0.04 % + 0.6R Fluke 271A/PM500- A350K/PM500- BG10M Fluke M1900/3 deadweight tester Torque – Watches & Transducers (6 to 250) gf·cm (1 to 80) ozf·in (5 to 400) lbf·in (30 to 300) lbf·ft (300 to 4000) lbf·ft 0.11 gf·cm + 0.002 % 0.026 ozf·in + 0.02 % 0.027 lbf·in + 0.01 % 0.027 lbf·ft + 0.01 % 0.006 lbf·ft + 0.02 % Calibrated weights, torque wheels & arms
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 15 of 16 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Torque – Wrenches & Drivers (4 to 20) ozf·in (2 to 10) lbf·in (5 to 50) lbf·in (25 to 250) lbf·in (100 to 1000) lbf·in (25 to 250) lbf·ft 0.88 % 1.1 % 1.0 % 1.0 % 1.0 % 1.0 % BMX LTT10I TTPM-41, 2000-400-02 Force3 – Measuring Equipment (1 to 500) gf (0.5 to 200) kgf (1 to 921) lbf 0.04 % + 1 digit 0.05 % + 1 digit 0.08 % + 1 digit Calibrated weights Accelerometers (0.5 to 10) Hz (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz 921 Hz to 5 kHz (5 to 10) kHz (10 to 15) kHz (15 to 20) kHz 1.3 % 2.2 % 1.3 % 1.1 % 1.2 % 1.5 % 2.1 % 2.6 % 3.6 % The Modal Shop Long stroke 9155D V. Thermodynamics Parameter/Equipment Range CMC2, 4, 6 (±) Comments Humidity3 – Measure (10 to 90) % RH 0.93 % RH Rotronic HC2A-SH Humidity – Generate (10 to 95) % RH 0.36 % RH Thunder Scientific 2500S Software, Fluke 2271A/PM500-A350K, PM500-BG10M, SPRT, RTD, DMM, WIKA CTB9100 Temperature3 – Measure & Measuring Equipment (-196 to 0) °C (0 to 420) °C 40 mK 50 mK SPRT 5614, WIKA dry well, liquid well
4 to 20 ozf·in
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 16 of 16 VI. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment, Fixed Point 10 MHz 1.6 parts in 1012 Fluke 910R Frequency – Measure 1 mHz to 26.5 GHz 1.6 parts in 1012 + 1 LSD Agilent 53131A, Keysight E4440A, Fluke 910R Frequency – Measuring Equipment 1 μHz to 30 MHz 30 MHz to 3 GHz (3 to 26.5) GHz 0.64 μHz 23 mHz 0.2 Hz 33519B, N5181B, 8340A, Fluke 910R _________________________________________________ 1 This laboratory offers commercial calibration services and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC percentage refers to percent of reading unless stated otherwise, L is the numerical value of the nominal length in inches, M is the applied mass in grams and R is the numerical value of the resolution of the device under test; for analog indicating devices R is considered to be equal to ½ the division width provided the ratio of needle width to division width does not interfere with reporting the reading to the nearest half-increment. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
17ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

6640 185th Ave NE, Redmond, WA, 98052, US

47.66521, -122.09278

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.