Cascade Engineering Services
6640 185th Ave NE, 98052, Redmond, WA, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 2560.01 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 2 of 16
Parameter/Equipment
Range CMC2, 4 (±) Comments
Thread Plug Gages – English &
Metric, 60° Pitch Diameter,
(8 to 80) TPI –
Major Diameter
Pitch Diameter
(0.06 to 4) in
(0.05 to 2.5) in
(>2.5 to 4) in
(10 + 5.5L) µin
140 µin
150 µin
P&W Labmaster
TM,
gage blocks, thread
wires
Cylindrical Plug Gages &
Thread Wires
Up to 7 in
(10 + 5.5L) µin
P&W LabmasterTM,
gage blocks
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Voltage3 – Generate
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1000) V
9.9 µV/V + 0.40 µV
5.8 µV/V + 0.70 µV
4.0 µV/V + 2.5 µV
4.0 µV/V + 4.0 µV
5.8 µV/V + 40 µV
7.5 µV/V + 0.40 mV
Fluke 5720A
DC Voltage3 – Measure
(0 to 100) mV
(100 to 200) mV
200 mV to 1 V
(1 to 2) V
(2 to 10) V
(10 to 20) V
(20 to 200) V
(200 to 1000) V
(0 to 10) kV
26 µV/V + 0.30 µV
6.9 µV/V + 0.10 µV
9.9 µV/V + 0.30 µV
3.5 µV/V + 0.40 µV
9.6 µV/V + 0.50 µV
3.5 µV/V + 4.0 µV
5.2 µV/V + 40 µV
5.2 µV/V + 0.05 mV
0.04 % + 30 mV
HP 3458A
Fluke 8508A
Vitrek 4700 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 3 of 16
Parameter/Equipment
Range CMC2, 5 (±) Comments
DC Current3 – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11.0) A
(11 to 20) A
46 µA/A + 6.0 nA
40 µA/A + 7.0 nA
40 µA/A + 40 nA
63 µA/A + 0.70 µA
150 µA/A + 12 µA
420 µA/A + 0.48 mA
0.12 % + 0.75 mA*
Fluke 5720A
Fluke 5720A & 5725A
Fluke 5520A-SC1100
*floor after 30 s
DC Current3 – Measure
(0 to 0.1) µA
(0.1 to 1) µA
(1 to 10) µA
(10 to 200) µA
(0.2 to 2) mA
(10 to 20) mA
(20 to 200) mA
200 mA to 1 A
(1 to 2) A
(2 to 20) A
0.15 % + 40 pA
91 µA/A + 40 pA
55 µA/A + 0.10 nA
18 µA/A + 0.40 nA
14 µA/A + 4.0 nA
15 µA/A + 40 nA
42 µA/A + 0.80 µA
180 µA/A + 10 µA
200 µA/A + 16 µA
440 µA/A + 0.4 mA
HP 3458A, Fluke 8508A
Resistance3 – Generate,
Fixed Points
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
59 µΩ
110 µΩ
210 µΩ
270 µΩ
510 µΩ
1.2 mΩ
2.2 mΩ
9.8 mΩ
19 mΩ
98 mΩ
190 mΩ
1.3 Ω
2.4 Ω
23 Ω
46 Ω
460 Ω
1.0 kΩ
12 kΩ
Fluke 5720A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 4 of 16
Parameter/Equipment
Range CMC2, 5 (±) Comments
Resistance3 – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
(0.0 to 0.01) Ω
18 µΩ/Ω + 4 µΩ
11 µΩ/Ω + 14 µΩ
9.9 µΩ/Ω + 50 µΩ
9.9 µΩ/Ω + 0.5 mΩ
9.9 µΩ/Ω + 5 mΩ
9.9 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1 Ω
18 µΩ/Ω + 10 Ω
69 µΩ/Ω + 1 kΩ
170 µΩ/Ω + 100 kΩ
610 µΩ/Ω + 10 MΩ
250 µΩ/Ω + 0.06 µΩ
Fluke 8508A
Fluke 5720, Fluke
8508A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4000 to 1.0999) nF
(1.1000 to 3.2999) nF
(3.3000 to 10.9999) nF
(11.0000 to 109.999) nF
(110.000 to 329.999) nF
(0.330 00 to 1.099 99) µF
(1.100 00 to 3.299 99) µF
(3.3000 to 10.9999) µF
(11.0000 to 32.9999) µF
(33.000 to 109.999) µF
(110.000 to 329.999) µF
(0.330 00 to 1.099 99) mF
(1.100 00 to 3.299 99) mF
(3.3000 to 10.9999) mF
(11.0000 to 32.9999) mF
(33.00 to 110.00) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.85 % + 0.010 nF
0.62 % + 0.010 nF
0.59 % + 0.010 nF
0.30 % + 0.010 nF
0.30 % + 0.10 nF
0.30 % + 0.30 nF
0.29 % + 1.0 nF
0.30 % + 3.0 nF
0.30 % + 10 nF
0.47 % + 30 nF
0.53 % + 0.10 µF
0.53 % + 0.30 µF
0.53 % + 1.0 µF
0.52 % + 3.0 µF
0.52 % + 10 µF
0.87 % + 30 µF
1.3 % + 0.10 mF
Fluke 5520A-
SC1100 | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 5 of 16
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Capacitance – Measure @ 1
kHz
Up to 10 pF
(10 to 100) pF
(100 to 400) pF
(400 to 1600) pF
(1600 to 6400) pF
6400 pF to 25 nF
(25 to 100) nF
(100 to 400) nF
(400 to 1600) nF
1600 nF to 6 µF
(6 to 25) µF
(25 to 100) µF
(100 to 1000) µF
0.48 %
0.06 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.06 %
0.48 %
GenRad 1689-9700
Oscilloscopes3 –
Amplitude DC Signal
50 Ω Load
1 MΩ Load
Leveled Sine Flatness
50 kHz Reference
Time Marker
50 Ω Load
Rise Time
(0 to ± 6.6) V
(0 to ± 130) V
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
1 ns to 20 ms
50 ms to 5 s
≤2 MHz
>2 MHz
0.28 % + 40 µV
0.057 % + 40 µV
1.9 % + 0.10 mV
2.4 % + 0.10 mV
4.6 % + 0.10 mV
5.7 % + 0.10 mV
2.8 µs/s
(29 + 1000t) µs/s
300 ps
350 ps
Fluke 5520-SC1100
t = time interval (s) | to 1000 µF |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 6 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple3 – Generate
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25.0) °C
(-25.0 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30.0) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0.0) °C
(0.0 to 120) °C
(120 to 400) °C
0.60 °C
0.19 °C
0.60 °C
0.19 °C
0.25 °C
0.32 °C
0.19 °C
0.30 °C
0.20 °C
0.27 °C
0.39 °C
0.21 °C
0.27 °C
0.31 °C
0.48 °C
0.75 °C
0.29 °C
0.27 °C
0.17 °C
Fluke 5520-
SC1100
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Generate
(0 to 2.2) mV
(2.2 to 22) mV
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
280 µV/V + 4.0 µV
100 µV/V + 4.0 µV
240 µV/V + 4.0 µV
580 µV/V + 5.0 µV
0.16 % + 20 µV
0.31 % + 20 µV
280 µV/V + 4.0 µV
100 µV/V + 4.0 µV
240 µV/V + 4.0 µV
580 µV/V + 5.0 µV
0.16 % + 20 µV
0.31 % + 20 µV
Fluke 5720A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 7 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Generate
(cont)
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(15 to 50) Hz
50 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
280 µV/V + 12 µV
100 µV/V + 7.0 µV
240 µV/V + 7.0 µV
530 µV/V + 17 µV
0.16 % + 25 µV
0.31 % + 45 µV
280 µV/V + 40 µV
100 µV/V + 15 µV
110 µV/V + 10 µV
140 µV/V + 30 µV
0.12 % + 0.20 mV
0.20 % + 0.30 mV
280 µV/V + 0.40 mV
100 µV/V + 0.15 mV
110 µV/V + 0.10 mV
130 µV/V + 0.20 mV
0.12 % + 2.0 mV
0.17 % + 3.2 mV
280 µV/V + 4.0 mV
100 µV/V + 1.5 mV
110 µV/V + 1 mV
180 µV/V + 2.5 mV
350 µV/V + 16 mV
81 µV/V + 3.5 mV
200 µV/V + 6.0 mV
700 µV/V + 11 mV
700 µV/V + 11 mV
0.27 % + 45 mV
Fluke 5720A
With Fluke 5725A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 8 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
(0 to 10) mV
(10 to 100) mV
(10 to 200) mV
100 mV to 1 V
100 mV to 2 V
(1 to 10) V
(2 to 20) V
(10 to 20) Hz
(20 to 40) Hz
(40 to 100) Hz
100 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(1 to 2) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 2) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.48 % + 3.0 µV
0.18 % + 3.0 µV
0.08 % + 1.1 µV
0.043 % + 1.1 µV
0.18 % + 1.1 µV
0.84 % + 1.1 µV
4.8 % + 2.0 µV
2.4 % + 10 µV
3.6 % + 10 µV
6.0 % + 10 µV
12 % + 10 µV
180 µV/V + 14 µV
150 µV/V + 4 µV
130 µV/V + 4 µV
120 µV/V + 2 µV
120 µV/V + 4 µV
350 µV/V + 8 µV
810 µV/V + 20 µV
12 % + 0.10 mV
160 µV/V + 120 µV
120 µV/V + 20 µV
98 µV/V + 20 µV
75 µV/V + 20 µV
98 µV/V + 20 µV
240 µV/V + 40 µV
580 µV/V + 200 µV
0.35 % + 2 mV
1.2 % + 20 mV
12 % + 1.0 mV
160 µV/V + 1.2 mV
120 µV/V + 0.20 mV
98 µV/V + 0.20 mV
75 µV/V + 0.20 mV
98 µV/V + 0.20 mV
240 µV/V + 0.40 mV
580 µV/V + 2.0 mV
0.35 % + 20 mV
1.2 % + 0.20 V
HP 3458A
Fluke 8508A
HP 3458A
Fluke 8508A
HP 3458A
Fluke 8508A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 9 of 16
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage3 – Measure
(cont)
(20 to 200) V
(200 to 1000) V
(0 to 7) kV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(50 to 60) Hz
160 µV/V + 12 mV
120 µV/V + 2.0 mV
98 µV/V + 2.0 mV
75 µV/V + 2.0 mV
98 µV/V + 2.0 mV
240 µV/V + 4.0 mV
580 µV/V + 20 mV
0.35 % + 200 mV
1.2 % + 2.0 V
160 µV/V + 70 mV
130 µV/V + 20 mV
110 µV/V + 20 mV
240 µV/V + 40 mV
590 µV/V + 0.20 V
0.15 % + 0.10 V
Fluke 8508A
Vitrek 4700
AC Current3 – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.16 % + 16 nA
0.15 % + 10 nA
0.10 % + 8.0 nA
0.33 % + 12 nA
0.73 % + 65 nA
0.099 % + 40 nA
0.088 % + 35 nA
0.072 % + 35 nA
0.31 % + 0.11 µA
0.71 % + 0.65 µA
0.093 % + 0.40 µA
0.081 % + 0.35 µA
0.072 % + 0.35 µA
0.31 % + 0.55 µA
0.71 % + 5.0 µA
Fluke 5720A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 10 of 16
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Current3 – Generate
(cont)
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(40 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.092 % + 4.0 µA
0.081 % + 3.5 µA
0.078 % + 2.5 µA
0.32 % + 3.5 µA
0.71 % + 10 µA
0.61 % + 35 µA
0.40 % + 80 µA
2.0 % + 1.6 mA
0.11 % + 0.17 mA
0.25 % + 0.38 mA
1.0 % + 0.75 mA
0.19 % + 5.9 mA
0.21 % + 5.9 mA
3.7 % + 5.9 mA
Fluke 5720A
Fluke 5720A
With Fluke 5725A
Fluke 5520A-SC1100
AC Current3 – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 100) mA
(20 to 200) mA
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(30 to 50) kHz
(50 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
550 µA/A + 20 nA
550 µA/A + 20 nA
750 µA/A + 20 nA
0.46 % + 20 nA
330 µA/A + 0.20 µA
320 µA/A + 0.20 µA
750 µA/A + 0.20 µA
0.46 % + 0.20 µA
330 µA/A + 2.0 µA
320 µA/A + 2.0 µA
750 µA/A + 2.0 µA
0.46 % + 2.0 µA
0.48 % + 20 µA
0.48 % + 20 µA
330 µA/A + 20 µA
290 µA/A + 20 µA
690 µA/A + 20 µA
Fluke 8508A
HP 3458A, option II
Fluke 8508A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 11 of 16
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current3 – Measure
(cont)
100 mA to 1 A
200 mA to 2 A
(2 to 20) A
(20 to 100) A
(100 to 200) A
(200 to 1200) A
(30 to 50) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(30 to 1000) Hz
(30 to 1000) Hz
(30 to 1000) Hz
1.2 % + 0.40 mA
690 µA/A + 0.20 mA
820 µA/A + 0.20 mA
0.35 % + 0.20 mA
920 µA/A + 2.0 mA
0.29 % + 2.0 mA
0.58 % + 20 mA
0.35 % + 20 mA
0.36 % + 200 mA
HP 3458A, option II
Fluke 8508A
Fluke 8508A with
AEMC SR704
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
Low Resistance (Earth
Resistance)
3 – Generate
100 mΩ to 4.99 Ω
(5 to 29.9) Ω
(30 to 199.9) Ω
(200 to 499) Ω
500 Ω to 1.999 kΩ
(2 to 4.99) kΩ
(5 to 10) kΩ
0.012 Ω + 0.4 %
0.016 Ω + 0.23 %
0.057 Ω + 0.22 %
0.31 Ω + 0.23 %
0.57 Ω + 0.21 %
0.49 %
14 Ω + 0.16 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
High Resistance (Insulation
Resistance)
3 – Generate
(10 to 39.99) kΩ
(40 to 99.99) kΩ
(100 to 199.99) kΩ
(200 to 999.99) kΩ
(1 to 9.999) MΩ
(10 to 999.9) MΩ
(1 to 10) GΩ
100 GΩ
47 Ω + 0.16 %
23 Ω + 0.22 %
11 Ω + 0.23 %
8.6 Ω + 0.23 %
1.8 Ω + 0.35 %
2.9 Ω + 0.6 %
1.1 MΩ + 1.2 %
3.5 GΩ
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
High Resistance (Insulation
Resistance)3 – Source with R
Multiplier
(0.35 to 99.99) GΩ
(100 to 999.9) GΩ
(1 to 10) TΩ
2.6 MΩ + 2 %
6.3 kΩ + 2.9 %
4.9 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 12 of 16
Parameter/Equipment
Range CMC2, 4, 5 (±) Comments
Ground Bond Resistance3 –
Decade Source, Fixed Points
25 mΩ
50 mΩ
100 mΩ
330 mΩ
500 mΩ
1 Ω
1.8 Ω
5 Ω
10 Ω
18 Ω
50 Ω
100 Ω
180 Ω
500 Ω
1 kΩ
1.8 kΩ
6 mΩ
6.2 mΩ
6.7 mΩ
10 mΩ
12 mΩ
0.014 Ω
0.022 Ω
0.037 Ω
0.1 Ω
0.21 Ω
0.43 Ω
0.82 Ω
1.5 Ω
3.4 Ω
6.3 Ω
30 Ω
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
Leakage Current3 – Generate
Passive/Differential
Active
(0.1 to 30) mA
(0.1 to 30) mA
2.6 µA + 0.46 %
3.1 µA + 0.45 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
Residual Current Device3 –
Trip Current
Trip Time Range
(3 to 3000) mA
(10 to 5000) ms
1.2 %
0.29 ms + 0.024 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
AC/DC Multimeter3 –
DC, 20 Hz to 2 kHz
(1 to 10) V
(10 to 100) V
(100 to 1100) V
6 mV + 0.18 %
59 mV + 0.23 %
0.64 V + 0.24 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD
AC/DC Multimeter3 –
DC, 20 Hz to 400 Hz
(30 to 300) mA
300 mA to 3 A
(3 to 30) A
0.1 mA + 0.26 %
1.8 mA + 0.18 %
18 mA + 0.35 %
Fluke 5320A, HVA,
80k-40 & 5320A-
LOAD | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 13 of 16
Parameter/Equipment
Range CMC2, 5 (±) Comments
AC/DC Current3 – Hipot
Leakage Current Measurement
DC, 20 Hz to 2 kHz
(30 to 300) µA
300 µA to 3 mA
(3 to 30) mA
(30 to 300) mA
0.15 µA + 0.79 %
2.1 µA + 0.24 %
17 µA + 0.24 %
0.19 mA + 0.23 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
DC Voltage Calibrator3
(3 to 30) V
(30 to 150) V
(150 to 600) V
0.01 V + 0.13 %
0.034 V + 0.13 %
0.23 V + 0.12 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
AC Voltage Calibrator3 –
(40 to 400) Hz
(3 to 30) V
(30 to 100) V
(100 to 300) V
(300 to 600) V
0.01 V + 0.14 %
0.022 V + 0.17 %
0.13 V + 0.12 %
0.26 V + 0.11 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
Frequency Calibrator3
(40 to 400) Hz
0.0062 Hz + 0.06 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
DC Voltage3 – High Resistance
Decade
2000 V Range
<1 MΩ
>1 MΩ
2.4 V + 1.3 %
5.7 V + 1.3 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
Test Current – Measure3
AC + DC rms
(0 to 400) mA
0.36 mA + 10 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD
DC High Voltage – Measure3
(5320A with 10 kV Adapter)
(5320A with HV Probe)
(>10 to 40) kV
0.012 kV + 0.62 %
Fluke 5320A, HVA, 80k-
40 & 5320A-LOAD | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 14 of 16
Parameter/Equipment
Range CMC2, 5 (±) Comments
AC High Voltage – Measure3
(50 to 60) Hz
(5320A with HV Probe)
(>10 to 40) kV
0.016 kV + 0.62 %
Fluke 5320A,
HVA, 80k-40 &
5320A-LOAD
III. Electrical – RF/Microwave
Parameter/Range Frequency CMC
2, 5 (±) Comments
Total Harmonic Distortion –
Measure
3 Hz to 3 GHz
0.49 dB
Keysight E4440A
IV. Mechanical
Parameter/Equipment Range CMC2, 4, 6 (±) Comments
Scales & Balances3
(1 to 500) mg
(1 to 600) g
200 g to 20 kg
(1/32 to 64) oz
(0.5 to 50) lb
(0.5 to 1000) lb
0.73 % + 0.6R
(260 + 2M) µg + 0.6R
22 µg/g + 0.6R
0.17 % + 0.6R
0.04 % + 0.6R
0.16 lb + 0.6R
Class 0 weights
Class 0 weights
Class 2 weights
Class F weights
Class F weights
Class F weights
Pressure3 –
Measure/Measuring
Equipment
(0 to 50) psia
(-14.5 to 500) psig
(0 to 1500) psig
(1500 to 4000) psig
0.032 psi
0.24 psi
0.23 psi + 0.004 %
0.04 psi + 0.04 % + 0.6R
Fluke
271A/PM500-
A350K/PM500-
BG10M
Fluke M1900/3
deadweight tester
Torque – Watches &
Transducers
(6 to 250) gf·cm
(1 to 80) ozf·in
(5 to 400) lbf·in
(30 to 300) lbf·ft
(300 to 4000) lbf·ft
0.11 gf·cm + 0.002 %
0.026 ozf·in + 0.02 %
0.027 lbf·in + 0.01 %
0.027 lbf·ft + 0.01 %
0.006 lbf·ft + 0.02 %
Calibrated weights,
torque wheels &
arms | ||
| 15 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 15 of 16
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
Torque – Wrenches &
Drivers
(4 to 20) ozf·in
(2 to 10) lbf·in
(5 to 50) lbf·in
(25 to 250) lbf·in
(100 to 1000) lbf·in
(25 to 250) lbf·ft
0.88 %
1.1 %
1.0 %
1.0 %
1.0 %
1.0 %
BMX
LTT10I
TTPM-41, 2000-400-02
Force3 – Measuring
Equipment
(1 to 500) gf
(0.5 to 200) kgf
(1 to 921) lbf
0.04 % + 1 digit
0.05 % + 1 digit
0.08 % + 1 digit
Calibrated weights
Accelerometers
(0.5 to 10) Hz
(5 to 9) Hz
(10 to 99) Hz
100 Hz
(101 to 920) Hz
921 Hz to 5 kHz
(5 to 10) kHz
(10 to 15) kHz
(15 to 20) kHz
1.3 %
2.2 %
1.3 %
1.1 %
1.2 %
1.5 %
2.1 %
2.6 %
3.6 %
The Modal Shop
Long stroke
9155D
V. Thermodynamics
Parameter/Equipment Range CMC2, 4, 6 (±) Comments
Humidity3 – Measure
(10 to 90) % RH
0.93 % RH
Rotronic HC2A-SH
Humidity – Generate
(10 to 95) % RH
0.36 % RH
Thunder Scientific
2500S Software, Fluke
2271A/PM500-A350K,
PM500-BG10M, SPRT,
RTD, DMM, WIKA
CTB9100
Temperature3 – Measure &
Measuring Equipment
(-196 to 0) °C
(0 to 420) °C
40 mK
50 mK
SPRT 5614, WIKA dry
well, liquid well | 4 to 20 ozf·in |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2560.01) REVISED 11/21/2025 Page 16 of 16
VI. Time & Frequency
Parameter/Equipment Range CMC2, 6 (±) Comments
Frequency – Measuring
Equipment, Fixed Point
10 MHz
1.6 parts in 1012
Fluke 910R
Frequency – Measure
1 mHz to 26.5 GHz
1.6 parts in 1012 + 1 LSD
Agilent 53131A,
Keysight E4440A,
Fluke 910R
Frequency – Measuring
Equipment
1 μHz to 30 MHz
30 MHz to 3 GHz
(3 to 26.5) GHz
0.64 μHz
23 mHz
0.2 Hz
33519B, N5181B,
8340A, Fluke 910R
_________________________________________________
1 This laboratory offers commercial calibration services and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC percentage refers to percent of reading unless stated otherwise, L is the numerical
value of the nominal length in inches, M is the applied mass in grams and R is the numerical value of the
resolution of the device under test; for analog indicating devices R is considered to be equal to ½ the
division width provided the ratio of needle width to division width does not interfere with reporting the
reading to the nearest half-increment.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 17 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - SeattleRedmond, WA · ~2 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ThermetricsSeattle, WA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Eustis Co., Inc./Pyrocom CalibrationLynnwood, WA · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Robb Precision Tool ServicesLynnwood, WA · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Global Calibration ServicesTukwila, WA · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.