Medtronic Plc. (Reliability Assurance & Design Assurance Laboratories)
7000 Central Ave NE, 55432, Fridley, MN, United States
Visit website- Accredited standards
- 20
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 20 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM8
ASTM D4169
ASTM D5265
ASTM D6797
ASTM F88
ASTM F1929
ASTM F2052
ASTM F2096
ASTM F2213
ISO5
ISO 5841-3Implants for surgery - Cardiac pacemakers - Part 3: Low-profile connectors (IS-1) for implantable pacemakersSome clauses
Limits written next to it
ISO 5841-3 Cl. 4.2.2.2 & Annex A
ISO 11318Cardiac defibrillators - Connector assembly DF-1 for implantable defibrillators - Dimensions and test requirements
ISO 13934-1Textiles - Tensile properties of fabrics - Part 1: Determination of maximum force and elongation at maximum force using the strip method
ISO 14117Active implantable medical devices - Electromagnetic compatibility - EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices
ISO 27186Active implantable medical devices - Four-pole connector system for implantable cardiac rhythm management devices - Dimensional and test requirementsSome clauses
Limits written next to it
ISO 27186 Cl. 4.3.6 & Annex A
EN 45502 series3
EN 45502-1
EN 45502-2-1Some clauses
Limits written next to it
EN 45502-2-1 Cl. 6.2.2 & 6.2.3
EN 45502-2-2Some clauses
Limits written next to it
EN 45502-2-2 Cl. 3.5.7 & 3.5.8
EN 45502-2-2, Cl.23.7
EN 45502-2-2 Cl
ISO 14708 series3
ISO 14708-1Implants for surgery - Active implantable medical devices - Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
ISO 14708-2Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakersSome clauses
Limits written next to it
ISO 14708-2 Cl. 3.16 & 6.2.3
ISO 14708-6Implants for surgery - Active implantable medical devices - Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)Some clauses
Limits written next to it
ISO 14708-6 Cl. 2.10
Other standards1
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performanceSome clauses
Limits written next to it
EN/IEC 60601-1: Cl.15.3.4.1
EN/IEC 60601-1: Cl.15.3.4.2
EN 45502-2-1; EN 45502-2-2; ISO 14708-2; ISO 14708-6; EN 45502-1; ASTM F88/F88M; ASTM F2096; ASTM D4169; ASTM D5265; ASTM F1929; EN/IEC 60601-1; ANSI/AAMI ES60601-1; ISO 27186; ISO 5841-3
EN/IEC 60601-1; ANSI/AAMI ES60601-1; EN 45502-2-1; ISO 14708-2; EN 45502-2-2; ISO 14708-6; ISO 27186; ISO 5841-3; ISO 11318; ASTM D6797-24; ISO 13934-1
ASTM F2052; ASTM F2213; ISO/TS 10974
ISO 27186 Cl. 4.3.6 & Annex A; ISO 5841-3 Cl. 4.2.2.2 & Annex A; ISO 14708-2 Cl. 3.16 & 6.2.3; ISO 14708-6 Cl. 2.10; EN 45502-2-1 Cl. 6.2.2 & 6.2.3; EN 45502-2-2 Cl. 3.5.7 & 3.5.8
ISO 14117; EN 45502-2-1; EN 45502-2-2; ISO 14708-1; ISO 14708-2; ISO 14708-6; EN 45502-1; ANSI/AAMI PC-69; ISO 11318; ISO 27186
ISO 14117; EN 45502-2-1; EN 45502-2-2; ISO 27186; ISO 11318
EN/IEC 60601-1; ANSI/AAMI ES60601-1; EN45502-1; ISO 14708-1; ISO 14708-2; ISO 14708-6
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active3493.01
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active3493.02
The scope document we hold says it is valid until 2027-08-31.
Location
Labs with overlapping accredited scope in United States
- DDL, Inc.Eden Prairie, MN · ~30 kmA2LAShares 1 accredited test methodASTM D4169
- Packaging ComplianceKentwood, MI · ~657 kmA2LAShares 1 accredited test methodASTM D4169
- SMITHERS DTLansing, MI · ~744 kmA2LAShares 1 accredited test methodASTM D4169
- ELEMENT MATERIALS TECHNOLOGY DENVER – LONGMONTLongmont, CO · ~1,111 kmA2LAShares 1 accredited test methodASTM D4169
- Eurofins LancasterLancaster, PA · ~1,494 kmA2LAShares 1 accredited test methodASTM D4169
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.