Eurofins Electrical and Electronic Testing NA
1 Distribution Center Cir #1, 01460, Littleton, MA, United States
Visit website- Accredited standards
- 79
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
In our data, A2LA certificates 591.12 and 591.13 carry the same scope document, so its lines are read once.
Only this lab. Searches the 79 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC22
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60533
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60825-1
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61851-1
IEC 62109-1
IEC 62109-2
IEC 62116
IEC 62236-4
IEC 62304
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
Show all 22
IEC 62366-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62477-1
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62485-1
IEC 62485-5
IEC 62619Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62909-1
IEC 80601-2-77
IEC 80601-2-78
ETSI15
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330-1
ETSI EN 300 330-2
ETSI EN 300 440-1
ETSI EN 300 440-2
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-52
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 302 502
IEC 60601 series8
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance+1 national
National versions in the same scope
AS/NZS 60601.1probably the same standard; matched by number only
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-2-10
IEC 60601-2-18
IEC 60601-2-37
IEC 60601-2-46Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
IEC 61010 series7
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-10
IEC 61010-2-010
IEC 61010-2-011
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-201
IEC 62933 series5
IEC 62933-1
IEC 62933-2
IEC 62933-3
IEC 62933-4
IEC 62933-5
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
KS C 9814-1national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 60947 series3
IEC 60947-1+1 national
National versions in the same scope
KS C IEC 60947-1probably the same standard; matched by number only
IEC 60947-2
IEC 60947-4-1
IEC 61326 series3
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61326-3-1
IEC 62040 series3
IEC 62040-1
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements+1 national
National versions in the same scope
KS C 9040-2national version with changes
IEC 62040-3
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.10
AS/NZS 62368.1
FCC PART 15Radio Frequency Devices
UL 62368-1
CAN/CSA C22.2 No. 61010-2-101; CAN/CSA C22.2 No. 61010-2-201; CAN/CSA C22.2 No. 62109-1; CAN/CSA C22.2 No. 62109-2; CAN/CSA C22.2 No. 62368-1; CSA C22.2 No 281.1; CSA C22.2 No 281.2; IEEE 1547; IEEE 1547.1; EN 60335-1; IEC 60335-1:2010; IEC/EN 60601-1; IEC 60601-1 Edition 3.2 2020-08
IEC 60601-2-37; IEC 60601-1; IEC 60825-1; IEC 61010-1; IEC 60335-1; IEC 62368-1
SANS 61326-2-4; EN 61326-2-5; IEC 61326-2-5; SANS 61326-2-5; EN 61326-2-6; IEC 61326-2-6; SANS 61326-2-6; EN 61326-3-1; IEC 61326-3-1; EN 62040-2; IEC 62040-2; EN 62040-3; IEC 62040-3; IEC TS 61000-6-5; IEEE 1613; IEEE C37.90.2:2004; UL 1449; IEC 60945; EN 60945; IEC 60533; DNVGL Class Guideline 0339 November 2019; IACS UR E10 Rev.7, 2018; Lloyd’s Register Type Approval System Test Specification Number 1, December 2020; AS/NZS 4268; Radiocommunications (Short Range Devices) Standard 2014; Radiocommunications (Low Interference Potential Devices) Class License 2000; Radiocommunications (Analogue Speech [Angle Modulated] Equipment) Standard 2014; RSS-GEN; RSS-111; RSS-112; RSS-117; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-141; RSS-142; RSS-170; RSS-181; RSS-182; RSS-192; RSS-194; RSS-195; RSS-196; RSS-197; RSS-199; RSS-210 (up to 40 GHz); RSS-213; RSS-215; RSS-216 (up to 40 GHz); RSS-220 (up to 40 GHz); RSS-222; RSS-236; RSS-238; RSS-243; RSS-247; RSS-287; RSS-288; RSS-310; ANSI C63.10-2020+Cor.1-2023+C63.10a-2024 + Errata to C63.10a-2024; Regulations on Radio Equipment (Ordinance of MSIT No. 86, Jan 4, 2022); Unlicensed Radio Equipment Established Without Notice (MSIT Public Notification 2023-18, Jun 20, 2023; Technical Requirements for Radio Equipment for Telecommunication Services (RRA Public Notification 2022-15, Jul 29, 2022); Technical Requirements for the Human Protection Against Electromagnetic Waves (MSIT Public Notification 2019-4, Jan 16, 2019); Technical Requirements for Measurement of Electromagnetic Field Strength (RRA Public Notification 2023-11, Jun 30, 2023)
IEC 62040-1; IEC 62116; IEC 62485-1; IEC 62485-5; IEC 61851-1; IEC 60730-1; IEC 62619; IEC 62933-1; IEC 62933-2; IEC 62933-3; IEC 62933-4; IEC 62933-5
IEC 61010-1; EN 61010-1; IEC 61010-2-010; EN 61010-2-10; IEC 61010-2-011; EN 61010-2-011; IEC/EN 61010-2-081; IEC/EN 61010-2-101; IEC/EN 61010-2-201; IEC 62368-1; EN 62368-1; IEC 62109-1; IEC 62109-2; IEC 62477-1; IEC 62909-1
47 CFR FCC Part 15B; ANSI C63.4:2014; 47 CFR FCC Part 18; FCC OET MP-5:1986; 47 CFR FCC Part 15C; ANSI C63.10:2020; 47 CFR FCC Part 15E; FCC KDB 905462 D02 v02; April 8, 2016; 47 CFR FCC Part 15F; 47 CFR FCC Parts 22; 24; 25; 27; 90; 95; 96; 97; 101; ANSI C63.26:2015; ANSI C63.10:2013; ANSI C63.10:2020; ICES-001; ICES-003; CISPR 11; EN 55011; SANS 211; AS CISPR 11; CISPR 14-1; EN 55014-1; SANS 214-1; AS/NZS CISPR 14.1; CISPR 22; EN 55022; SANS 222; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32:2016; SANS 2332; IEC 62236-4; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; SANS 61000-3-2; IEC 61000-3-12; EN 61000-3-12; SANS 61000-3-12; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; SANS 61000-3-3; IEC 61000-3-11; EN 61000-3-11; SANS 61000-3-11
IEC/EN 60601-1-6; IEC 60601-1-6 Edition 3.2 2020-07; IEC/EN 60601-1-8; IEC 60601-1-8 Edition 2.2 2020-07; IEC/EN 60601-2-18; IEC 60601-2-18 Edition 3.0 2009-08; IEC/EN 62304; IEC/EN 62366; IEC/EN 62366-1; IEC /EN 60601-2-10; IEC/EN 60601-2-37; IEC 60601-2-37 Edition 3.0 2024-07; IEC 60601-2-37 Edition 2.1 2015; IEC/EN 60601-2-46; IEC/EN 80601-2-77; IEC/EN 80601-2-78
KS X 3123; Technical Requirements for Electromagnetic Compatibility (RRA Public Notification 2023-13, Jun 30, 2023); Test Methods for Electromagnetic Compatibility (RRA Announcement May 31, 2022); KS C 9811:2019; KS C IEC 60601-1-2:2020; KS C 9990:2017; KS C 9814-1:2022; KS C 9814-2:2022; KS C 9815:2023; KS C 9547:2020; KN 50; KN 51; KS X 3124:2020; KS X 3125:2020; KS X 3126:2020; KS X 3129:2020; KS X 3141:2015; KS C 9040-2:2017; KS C IEC 60947-1:2014; KS C IEC 60947-2:2019; KS C IEC 60947-4-1:2018; KS C 9832:2019; KS C 9835:2019; KS C 9800-3:2017; KS X 3140:2014; KS C 9610-6-1:2019; KS C 9610-6-2:2019; KS C 9610-6-3:2023; KS C 9610-6-4:2022; EN 300 220-1; EN 300 220-2; EN 300 220-3; EN 300 330-1; EN 300 330-2; EN 300 440-1; EN 300 440-2; EN 300 328; EN 301 893; EN 302 502; EN 301 908-1 to 13; EN 301 489-01; EN 301 489-03; EN 301 489-17; EN 301 489-52; US FCC 47 CFR FCC Part 15B (using ANSI C63.4:2014); 47 CFR Part 18 (using FCC MP-5:1986); 47 CFR FCC Parts 15C/H (using ANSI C63.10:2020); 47 CFR FCC Part 15E (using ANSI C63.10:2020 or FCC KDB 905462 D02 v02, April 8, 2016); 47 CFR FCC Parts 22, (cellular), 24, 25, 27 (below 3 GHz), 90 (above 3 GHz), 95 (above 3 GHz), 96, 97 (above 3 GHz), and 101 (using ANSI/TIA-603-E and/or ANSI C63.26:2015); RF Exposure (excluding SAR) IEEE C95.3; FCC OET Bulletin 65; FCC OET Bulletin 65 Supplement C; EN 62311; IEC / EN 62479; UL 67
ANSI AAMI IEC 80601-2-77:2020; ANSI/AAMI 62304; ANSI/AAMI 62366-1; UL 61010-1; UL 61010-1 3rd Ed, dated May 12, 2012, with revision through July 19, 2019; UL 61010-2-010; UL 61010-2-011; UL 61010-2-081; UL 61010-2-101; UL 61010-2-201; UL 62368-1; UL 1741
SI 62368 Part 1; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020
ANSI C63.10:2020; FCC KDB 905462 D02 (v02), April 08, 2016; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
AS/NZS 62368.1; AS/NZS 60601.1; AS 61010.1; CAN/CSA C22.2 No. 0.8; CAN/CSA C22.3 No. 9; CAN/CSA C22.2 No. 244; CAN/CSA C22.2 No. 290; CAN/CSA C22.2 No. 330; CAN/CSA C22.2 No. 60335-1; CSA C22.2 No. 60601-1-2; CAN/CSA C22.2 No. 60601-1-6; CAN/CSA C22.2 No. 60601-1-8; CSA/CEI 62304
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.
Scope as published by A2LA
16 lines
ISO/IEC 17025
Active591.12
The scope document we hold says it is valid until 2028-06-30.
ISO/IEC 17025
Active591.13
Same scope document as certificate 591.12.
The scope document we hold says it is valid until 2028-06-30.
Location
Labs with overlapping accredited scope in United States
- Intertek Testing Services NABoxborough, MA · ~6 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- Intertek Testing Services NASkaneateles Falls, NY · ~407 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- Element Materials Technology Washington DCColumbia, MD · ~584 kmA2LAShares 2 accredited test methodsANSI C63.10:2020ANSI C63.4:2014
- DEKRA CertificationSterling, VA · ~633 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- Elite Electronic EngineeringDowners Grove, IL · ~1,360 kmA2LAShares 2 accredited test methodsANSI C63.10:2020ANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.