United States

CalSource

1005 West Fayette Street, Suite 4D, 13204, Syracuse, NY, United States

Visit website
A2LA 2133.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
26
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 26 scope lines.

A2LA certificate 2133.01 · 26 lines

LineMethodMatrixRange
1ISO 17025:2017-to 180 °
2ASMESteelSee scope document
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 3 of 25 Parameter/Equipment Range CMC2, 4 (±) Comments Surface Plates3 – Flatness Overall Flatness Local Area (Repeat Reading) Up to 70 in Diagonal (80 to 161) in Diagonal Up to 0.001 in 160 µin 280 µin 55 µin Planekator Datum gauge (Repeat-o-meterTM) II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Voltage3 – Measure Voltage Ratio Up to 200 mV 200 mV to 2V (2 to 20) V (20 to 200) V (200 to 1000) V (1 to 10) kV Up to 200 mV 200 mV to 20 V 4.2 µV/V + 0.5 µV 2.8 µV/V + 0.7 µV 3.0 µV/V + 1 µV 4.2 µV/V + 42 µV 4.5 µV/V + 0.6 mV 0.26 % 5.1 µV/V 8.1 µV/V Fluke 8588A HP 3458A w/ divider Fluke 8588A DC Voltage3 – Generate Fixed Point Up to 220 mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 10 V 10 µV/V + 0.4 µV 5.2 µV/V + 0.7 µV 4.1 µV/V + 3.0 µV 3.6 µV/V + 4.0 µV 6.1 µV/V + 50 µV 8.1 µV/V + 500 µV 2.0 parts in 106 V Fluke 5730A/03 Fluke 7000 & 7000N DC Current3 – Measure Up to 20 µA 20 µA to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2.0 A (2 to 20) A (20 to 30) A 25 µA/A + 6.9 nA 3.0 µA/A + 6.9 nA 6.4 µA/A + 8.7 nA 8.5 µA/A + 60 nA 33 µA/A + 1.3 µA 110 µA/A + 100 µA 140 µA/A + 1.8 mA 400 µA/A + 8.1 mA Fluke 8588A
to 70 in
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 4 of 25 Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Current3 – Generate (Toroidal & Other-type clamps) Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 10) A (10 to 20) A (20 to 1000) A 41 µA/A + 6 nA 36 µA/A + 7 nA 36 µA/A + 40 nA 44 µA/A + 1.4 µA 130 µA/A + 12 µA 380 µA/A + 480 µA 21 mA 0.65 % Fluke 5730A/03 w/ 5725A Fluke 5520 Fluke 5520 w/ coil Resistance3 – Measure Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (1 to 10) kΩ 18 µΩ/Ω + 4 µΩ 10 µΩ/Ω + 25 µΩ 9.0 µΩ/Ω + 220 µΩ 9.0 µΩ/Ω + 2.0 mΩ 9.0 µΩ/Ω + 20 mΩ 9.0 µΩ/Ω + 230 mΩ 10 µΩ/Ω + 3.5 Ω 15 µΩ/Ω + 250 Ω 120 µΩ/Ω + 11 kΩ 1.7 mΩ/Ω + 1.5 MΩ 1.7 µΩ/Ω Fluke 8588A Thomas 1 Ω & Fluke 8508A/01 Resistance3 – Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 330 MΩ to 1.1 GΩ 28 µΩ/Ω + 0.001 Ω 21 µΩ/Ω + 0.0015 Ω 21 µΩ/Ω + 0.0014 Ω 21 µΩ/Ω + 0.002 Ω 21 µΩ/Ω + 0.002 Ω 21 µΩ/Ω + 0.02 Ω 21 µΩ/Ω + 0.02 Ω 22 µΩ/Ω + 0.2 Ω 21 µΩ/Ω + 0.2 Ω 24 µΩ/Ω + 2 Ω 24 µΩ/Ω + 2 Ω 60 µΩ/Ω + 30 Ω 90 µΩ/Ω + 50 Ω 0.017 % + 2.5 kΩ 0.036 % 0.45 % 1.1 % Fluke 5520A
to 220 µA
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 5 of 25 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Resistance3 – Generate Fixed Points 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1 Ω 96 µΩ/Ω 96 µΩ/Ω 24 µΩ/Ω 24 µΩ/Ω 11 µΩ/Ω 11 µΩ/Ω 7.3 µΩ/Ω 7.4 µΩ/Ω 7.3 µΩ/Ω 7.4 µΩ/Ω 9.2 µΩ/Ω 9.2 µΩ/Ω 14 µΩ/Ω 19 µΩ/Ω 41 µΩ/Ω 49 µΩ/Ω 0.011 % 0.7 µΩ/Ω Fluke 5730A/03 Thomas 1 Ω
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 6 of 25 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Capacitance – Measure 100 pF to 100 µF 100 µF to 500 µF 100 µF to 1000 µF 1000 µF to 3300 µF 100 pF to 100 nF 100 nF to 100 µF 100 µF to 1000 µF 1 kHz Only 1 kHz Only 1 kHz Only 1 kHz Only 500 Hz to 10 kHz 12 Hz to 10 kHz 50 Hz to 2 kHz 0.07 % 0.25 % 0.48 % 1.50 % 0.20 % 0.20 % 1.90 % Genrad 1689 Phase3 – Generate (Dual ACV Outputs) 3.3V, PF 0 to 1 (0 to 90)° 3.3V, PF 1 (0 to 90)° (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.07° 0.17° 0.34° 1.7° 3.4° 6.7° Fluke 5520A Inductance – Generate 100 μH 1 mH 10 mH 100 mH 1 H 10 H 100 Hz to 10 kHz 100 Hz to 1 kHz 0.26 μH 0.0011 mH 0.011 mH 0.11 mH 0.0011 H 0.011 H General radio 1482-x standard inductors
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 7 of 25 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current3 – Generate Up to 220 μA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (20 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (40 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (6 to 10) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.029 % + 16 nA 0.019 % + 10 nA 0.014 % + 8 nA 0.031 % + 12 nA 0.12 % + 65 nA 0.027 % + 40 nA 0.020 % + 35 nA 0.010 % + 35 nA 0.023 % + 110 nA 0.13 % + 650 nA 0.028 % + 400 nA 0.020 % + 350 nA 0.015 % + 350 nA 0.024 % + 550 nA 0.12 % + 5 mA 0.028 % + 4.0 μA 0.021 % + 3.5 μA 0.017 % + 2.5 μA 0.025 % + 3.5 μA 0.12 % + 10 μA 0.028 % + 35 μA 0.051 % + 80 μA 0.74 % + 160 μA 0.052 % + 170 μA 0.11 % + 380 μA 0.38 % + 750 μA 0.019 % + 9.4 mA 0.03 % + 9.4 mA 0.085 % + 9.4 mA 0.25 % + 31 mA 0.82 % + 62 mA 2.4 % + 94 mA 0.33 % + 0.003A 0.91 % + 0.003A 0.33 % + 0.025A 0.92 % + 0.027A 0.35 % + 0.09A 0.93 % + 0.1A Fluke 5730A/03 Fluke 5730A/03 w/ 5725A Fluke 52120A LCOMP off Fluke 5522A & coil
to 1025 A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 8 of 25 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current3 – Measure Up to 20 μA (20 to 200) μA 200 μA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 30) A 1 Hz to 30 kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 10 kHz 10 Hz to 2 kHz (2 to 10) kHz 0.045 % + 2.5nA 0.033 % + 5 nA 0.050 % + 5 nA 0.084 % + 5 nA 0.48 % + 10 nA 0.027 % + 50 nA 0.053 % + 50 nA 0.083 % + 50 nA 0.42 % + 100 nA 0.027 % + 500 nA 0.061 % + 500 nA 0.078 % + 500 nA 0.42 % + 1 µA 0.027 % + 5 µA 0.052 % + 5 µA 0.091 % + 5 µA 0.027 % + 100 µA 0.054 % + 100 µA 0.074 % + 100 µA 0.083 % + 500 µA 0.081 % + 12 mA 0.085 % + 12 mA Fluke 8588A
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 9 of 25 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Generate Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.052 % + 4 µV 0.05 % + 4 µV 0.049 % + 4 µV 0.10 % + 4 µV 0.15 % + 5 µV 0.24 % + 10 µV 0.40 % + 20 µV 0.53 % + 20 µV 0.025 % + 4 µV 0.013 % + 4 µV 0.012 % + 4 µV 0.026 % + 4 µV 0.06 % + 5 µV 0.12 % + 10 µV 0.16 % + 20 µV 0.29 % + 20 µV 0.024 % + 12 µV 93 µV/V + 7 µV 61 µV/V + 7 µV 0.02 % + 7 µV 0.03 % + 17 µV 0.07 % + 20 µV 0.15 % + 25 µV 0.28 % + 45 µV Fluke 5730A/03
to 0.0022 V
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 10 of 25 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage3 – Generate (cont) (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (220 to 750) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz (30 to 50) kHz (50 to 100) kHz (1 to 20) kHz (20 to 30) kHz 0.024 % + 40 µV 93 μV/V + 15 µV 44 μV/V + 8 µV 70 μV/V + 10 µV 91 μV/V + 30 µV 0.04 % + 80 µV 0.10 % + 200 µV 0.18 % + 300 µV 0.024 % + 400 µV 92 µV/V + 150 µV 44 µV/V + 50 µV 70 µV/V + 100 µV 90 µV/V + 200 µV 0.027 % + 600 µV 0.11 % + 2 mV 0.16 % + 3.2 mV 0.024 % + 4 mV 93 µV/V + 1.5 mV 54 µV/V + 0.6 mV 83 µV/V + 1 mV 0.016 % + 2.5 mV 0.091 % + 16 mV 0.44 % + 40 mV 0.81 % + 80 mV 0.03 % + 16 mV 0.007 % + 3.5 mV 0.061 % + 11 mV 0.23 % + 45 mV 0.018 % + 6 mV 0.066 % + 11 mV Fluke 5730A/03 Fluke 5730A, volt- hertz limitation over 100 kHz. Max output is 2.2 x 10 7 V-Hz. Max 250 V for (15 to 50) Hz Fluke 5730A w/ 5725A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 11 of 25 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure 600 µV to 2.2 mV Flatness – 500 kHz to 30 MHz (Relative to 1 kHz) 600 µV to 2.2 mV (2.2 to 7) mV Flatness – 500 kHz to 30 MHz (Relative to 1 kHz) (2.2 to 7) mV (7 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (500 to 1000) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.24 % + 1.3 µV 0.13 % + 1.3 µV 0.12 % + 1.3 µV 0.14 % + 2.0 µV 0.19 % + 2.5 µV 0.36 % + 4.0 µV 0.61 % + 8.0 µV 0.71 % + 8.0 µV 0.094 % + 1.0 µV 0.12 % + 1.0 µV 0.19 % + 1.0 µV 0.33 % + 1.0 µV 0.83 % + 1.0 µV 1.10 % + 1.0 µV 0.099 % + 1.3 µV 0.058 % + 1.3 µV 0.046 % + 1.3 µV 0.078 % + 2.0 µV 0.12 % + 2.5 µV 0.22 % + 4.0 µV 0.28 % + 8.0 µV 0.052 % + 1.0 µV 0.054 % + 1.0 µV 0.095 % + 1.0 µV 0.17 % + 1.0 µV 0.35 % + 1.0 µV 0.51 % + 1.0 µV 0.031 % + 1.3 µV 0.023 % + 1.3 µV 0.017 % + 1.3 µV 0.028 % + 2.0 µV 0.039 % + 2.5 µV 0.086 % + 4.0 µV 0.12 % + 8.0 µV Fluke 5790B/05
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 12 of 25 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure (cont) (22 to 70) mV (70 to 220) mV (220 to 700) mV 700 mV to 2.2 V Flatness – 500 kHz to 30 MHz (Relative to 1 kHz) 7 mV to 7 V (2.2 to 7) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.027 % + 1.5 µV 0.017 % + 1.5 µV 91 µV/V + 1.5 µV 0.015 % + 2 µV 0.03 % + 2.5 µV 0.05 % + 4 µV 0.073 % + 8 µV 0.018 % + 1.5 µV 77 µV/V + 1.5 µV 40 µV/V + 1.5 µV 67 µV/V + 2 µV 0.015 % + 2.5 µV 0.023 % + 4 µV 0.037 % + 8 µV 0.018 % + 1.5 µV 66 µV/V + 1.5 µV 34 µV/V + 1.5 µV 48 µV/V + 2 µV 75 µV/V + 2.5 µV 0.017 % + 4 µV 0.028 % + 8 µV 0.017 % 54 µV/V 24 µV/V 43 µV/V 65 µV/V 0.016 % 0.025 % 0.063 % 0.067 % 0.092 % 0.15 % 0.31 % 0.48 % 0.016 % 59 µV/V 24 µV/V 46 µV/V 74 µV/V 0.02 % 0.037 % Fluke 5790B/05
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 13 of 25 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure (cont) Flatness – 10 Hz to 500 kHz (Relative to 1 kHz) (7 to 22) V (22 to 70) V (70 to 220) V (10 to 30) Hz 2.2 mV to 7 V (30 to 120) kHz 2.2 mV to 7 V (120 to 500) kHz (2.2 to 22) mV (120 to 500) kHz (22 to 70) mV (120 to 500) kHz (70 to 220) mV (120 to 500) kHz (220 to 700) mV (120 to 500) kHz 700 mV to 7 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.10 % 0.06 % 0.09 % 0.063 % 0.056 % 0.046 % 0.053 % 0.016 % 54 µV/V 23 µV/V 41 µV/V 71 µV/V 0.018 % 0.037 % 0.016 % 59 µV/V 27 µV/V 48 µV/V 81 µV/V 0.02 % 0.041 % 0.11 % 0.017 % 58 µV/V 30 µV/V 58 µV/V 88 µV/V 0.024 % 0.047 % Fluke 5790B/05
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 14 of 25 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure (cont) (220 to 700) V (700 to 1000) V (1 to 10) kV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (45 to 65) Hz 0.016 % 86 µV/V 36 µV/V 0.012 % 0.042 % 0.017 % 85 µV/V 42 µV/V 0.011 % 0.041 % 0.64 % Fluke 5790B/05 HP 3458A w/ divider Distortion – Measure 20 Hz to 20 kHz (20 to 100) kHz 1.3 dB 2.4 dB HP 8903B Parameter/Equipment Range CMC2, 6 (±) Comments Capacitance3 – Generate (0.19 to 3.3) nF (3.3 to 11) nF (11 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.37 % + 0.01 nF 0.28 % + 0.01 nF 0.23 % + 0.1 nF 0.23 % + 0.3 nF 0.23 % + 1 nF 0.23 % + 3 nF 0.24 % + 10 nF 0.32 % + 30 nF 0.34 % + 100 nF 0.35 % + 300 nF 0.35 % + 1 μF 0.32 % + 3 μF 0.32 % + 10 μF 0.52 % + 30 μF 0.81 % + 100 μF Fluke 5520A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 15 of 25 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicators 3 – Type B Type C Type E Type J Type K Type L Type N Type R (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 °C to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C 0.34 °C 0.27 °C 0.24 °C 0.26 °C 0.24 °C 0.21 °C 0.25 °C 0.39 °C 0.65 °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.22 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.32 °C 0.29 °C 0.21 °C 0.14 °C 0.32 °C 0.18 °C 0.15 °C 0.15 °C 0.22 °C 0.45 °C 0.28 °C 0.26 °C 0.32 °C Fluke 5520A
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 16 of 25 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicators – (cont) Type S Type T Type U (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 400) °C 0.37 °C 0.28 °C 0.30 °C 0.37 °C 0.50 °C 0.20 °C 0.14 °C 0.12 °C 0.44 °C 0.22 °C Fluke 5520A Electrical Simulation of RTD3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.041 °C 0.056 °C 0.072 °C 0.095 °C 0.097 °C 0.041 °C 0.057 °C 0.073 °C 0.081 °C 0.097 °C 0.21 °C 0.033 °C 0.041 °C 0.049 °C 0.056 °C 0.064 °C 0.073 °C 0.081 °C 0.19 °C Fluke 5520A AC Power, Low Frequency3 – Generate 3.3 mA to 21 A, (45 to 65) Hz (33 to 330) mV (0.33 to 1020) V 0.12 % 0.18 % Fluke 5520A
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 17 of 25 Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Power3 – Generate (0.33 to 30) mA (0.33 to 3) A (3 to 21) A 33 mV to 1020 V 33 mV to 1020 V 33 mV to 1020 V 0.019 % 0.019 % 0.071 % Fluke 5520A Phase - Measure (0 to 360°) 5 Hz to 2 kHz >2 kHz to 5 kHz >5 kHz to 10kHz >10 kHz to 50 kHz >50 kHz to 1 MHz 0.033° 0.04° 0.048° 0.057° 1.0° Clarke-Hess 6000A Oscilloscope3 – Squarewave Signal (50 Ω at 1 kHz) (1 MΩ at 1 kHz) Leveled Sine Wave Amplitude Flatness (Rel. to 50 kHz) Time Marker (50 Ω Source & Period) Rise Time 1 mV to 6.6 V 1 mV to 130 V 50 kHz reference 50 kHz to 500 MHz (500 to 3200) MHz 5 s to 50 ms 20 ms to 2 ns (125 to 175)ps 0.21 % + 40 μV 0.099 % + 40 μV 2.5 % 5 % 6.1 % 0.6 µs/s 0.33 µs/s 20 ps Fluke 5520A/SC600 Fluke 9500B/9530 Fluke 9500B/9530 Fluke 9500B/9530
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 18 of 25 III. Electrical – RF/Microwave Parameter/Equipment Range CMC2, 5 (±) Comments RF Power Reference 1 mW, 50 MHz 0.03 mW HP 478A w/ 432A & 3458A RF Power Sensor Calibration Factors 100 kHz to 4.6 GHz (4.6 to 18) GHz (18 to 26.5) GHz 1.0 % 1.7 % 4.7 % Tegam F1130B, Tegam 1830A HP 8485A, HP E4418B HP 11667B S-Parameter – S11/S22 Magnitude (linear) 100 kHz to 10 MHz 10 MHz to 3 GHz (3 to 9) GHz (9 to 18) GHz 0.5 % of rdg + 0.01 rho 0.7 % of rdg + 0.012 rho 1.6 % of rdg + 0.022 rho 3.9 % of rdg + 0.042 rho Keysight E5063A S-Parameter – S11/S22 Phase (Degrees)9 100 kHz to 10 MHz, rho >0.025 100 kHz to 10 MHz, rho >0.1 10 MHz to 3 GHz, rho>0.05 10 MHz to 3 GHz, rho>0.1 (3 to 9) GHz, rho>0.1 (3 to 9) GHz, rho>0.2 (9 to 18) GHz, rho >0.2 12° 3.9° 9.5° 5.1° 12° 6° 17° Keysight E5063A Attenuation – Source, 1dB Steps (1 to 3) dB, <1 GHz (1 to 3) dB, (1 to 11) GHz (1 to 3) dB, (11 to 18) GHz (4 to 7) dB, <1 GHz (4 to 7) dB, (1 to 11) GHz (4 to 7) dB, (11 to 18) GHz (8 to 11) dB, <1 GHz (8 to 11) dB, (1 to 11) GHz (8 to 11) dB, (11 to 18) GHz 0.19 dB 0.20 dB 0.19 dB 0.17 dB 0.15 dB 0.24 dB 0.26 dB 0.27 dB 0.58 dB HP8494B Attenuation – Source, 10dB Steps (10 to 30) dB, <1 GHz (10 to 30) dB, (1 to 11) GHz (10 to 30) dB, (11 to 18) GHz (40 to 70) dB, <1 GHz (40 to 70) dB, (1 to 11) GHz (40 to 70) dB, (11 to 18) GHz (80 to 110) dB, < 1GHz (80 to 110) dB, (1 to 11) GHz (80 to 110) dB, (11 to 18) GHz 0.24 dB 0.64 dB 1.6 dB 0.61 dB 0.66 dB 2.3 dB 0.59 dB 0.77 dB 4.7 dB HP8496B
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 19 of 25 Parameter/Equipment Range CMC2, 6 (±) Comments RF Power – Generate 100 kHz to 10 MHz (+20 to -100) dBm 10 MHz to 26.5 GHz (+20 to -100) dBm 1.1 dB 0.28 dB HP 8663A synthesizer HP 83630B synthesizer RF Power – Measure 100 kHz to 10 MHz (-20 to +20) dBm 10 MHz to 26 GHz (-1 to +20) dBm 0.73 dB 0.21 dB Power Meter & Sensors RF Tuned Power/Attenuation – Measure (2.5 to 1300) MHz (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (1.3 to 26.5) GHz (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB 0.038 dB 0.044 dB 0.048 dB 0.052 dB 0.073 dB 0.082 dB 0.091 dB 0.096 dB 0.12 dB 0.12 dB 0.13 dB 0.035 dB 0.042 dB 0.046 dB 0.050 dB 0.072 dB 0.081 dB 0.090 dB 0.095 dB 0.12 dB 0.12 dB 0.13 dB Agilent 8902A receiver Agilent 8902A receiver w/ 11793A converter
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 20 of 25 Parameter/Equipment Range CMC2, 6 (±) Comments Amplitude Modulation – Measure Rate: 50 Hz to 10 kHz Depth: (5 to 99) % Rate: 20 Hz to 10 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 20 Hz to 100 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % (0.15 to 10) MHz (0.15 to 10) MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 2.4 % 3.6 % 1.3 % 3.6 % 1.9 % 3.6 % Agilent 8902A Receiver Agilent 8902A Receiver w/ 11793A Converter Frequency Modulation – Measure Rate: 20 Hz to 10 kHz Dev: ≤ 40 kHz peak Rate: 50 Hz to 100 kHz Dev: ≤ 400 kHz peak Rate: 20 Hz to 200 kHz Dev: ≤ 4.0 kHz peak Rate: 50 Hz to 100 kHz Dev: ≤ 400 kHz peak Rate: 20 Hz to 200 kHz Dev: ≤ 400 kHz peak (0.15 to 10) MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GH 2.5 % 1.4 % 6.1 % 1.4 % 6.1 % Agilent 8902A Receiver Agilent 8902A Receiver w/ 11793A Converter Phase Modulation – Measure Rate: 200 Hz to 10 kHz Rate: 200 Hz to 20 kHz (0.15 to 10) MHz (0.01 to 26.5) GHz 4.9 % 3.7 % Agilent 8902A Receiver
0.01 to 26.5 GHz
21-water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 21 of 25 IV. Fluid Quantities Parameter/Equipment Range CMC2, 5, 8 (±) Comments Liquid Flow3 – Measure (1 to 10) GPM water 0.25 % Direct comparison using micro motion flow meter V. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure – Measuring Equipment & Measure3 – Gage/Absolute Pressure Hydraulic3 Negative Gage Pressure Barometric Low (0.2 to 25) psi (1.7 to 100) psi (2 to 1000) psi (1000 to 10 000) psig (-14.5 to 0) psig (10 to 16) psia (0.01 to 2) in H2O (2 to 10) in H2O 0.0020 % rdg 0.018 % rdg 29 x 10-5 psi 0.01 % + 0.0003 psia 0.0034 in H2O 0.0021 in H2O Ruska piston gage Ametek TQ-100 DWT Ruska piston gage DHI RPM4 Micro tector Hook gage
See scope document
22ison using Class 1-See scope document
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 23 of 25 Parameter/Equipment Range CMC2, 8 (±) Comments Torque – Measuring Equipment (2 to 20) ozf·in (15 to 200) ozf·in (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (100 to 1000) lbf·ft 0.064 ozf·in 0.59 ozf·in 0.15 lbf·in 1.2 lbf·in 3.0 lbf·in 0.73 lbf·ft 3.0 lbf·ft Torque arm & weights Torque Wrenches (1 to 20) ozf·in (20 to 200) ozf·in (5 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (100 to 1000) lbf·ft 0.41 ozf·in 0.61 % rdg 0.81 % rdg 0.61 % rdg 0.62 % rdg 0.70 % rdg 0.69 % rdg Torque arm & weights CDI torque system Force – Compression, Measuring Equipment Up to 5 lbf (5 to 50) lbf (50 to 2000) lbf (400 to 20 000) lbf 0.05 % 0.02 % 0.44 lbf 38 lbf Weights Load Cells Force – Tension, Measuring Equipment (100 to 2000) lbf 0.34 lbf Load cells
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 24 of 25 VI. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Relative Humidity - Measure3 (10 to 95) % RH 2.0 % RH Rotronic RH transmitter, Fluke Hydra data logger Temperature Measure 3 – (-197 to 100) °C (100 to 420) °C (-40 to 250) °F 0.016 °C 0.028 °C 0.05 °F Hart 1594A, SPRT Temperature Measuring Equipment (-40 to 150) °C (150 to 350) °C 0.016 °C 0.026 °C Hart 1594A, SPRT w/Fluid bath Hart 1594A, SPRT, w/Dry Well IR Thermometers (-15 to 120) °C (35 to 500) °C 1.2 °C 1.6 °C Hart Scientific 4180 Hart Scientific 4181 Emissivity 0.95 λ = (8 to 14) µm Welch Allyn Blackbody (29 to 43) °C 0.072 °C Master blackbody, SPRT VII. Time & Frequency Parameter/Equipment Range CMC2, 5, 8 (±) Comments Frequency – Measuring Equipment3 10 MHz 0.01 Hz to 225 MHz 200 Hz to 5 GHz 5 GHz to 26.5 GHz 1.7 pHz/ Hz 4.7 nHz/Hz 4.5 nHz/Hz 1.6 nHz/Hz Microchip S650, GPS Agilent 53132A, GPS HP 5352B, GPS Frequency – Measure3 0.01 Hz to 225 MHz 200 MHz to 5 GHz 5 GHz to 26.5 GHz 4.7 nHz/Hz 4.5 nHz/Hz 1.6 nHz/Hz Agilent 53132A, GPS HP 5352B, GPS Stopwatches & Timers3 (0 to 19.99) s/day 0.043 s/day Timometer 4500
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2133.01) 08/26/2024 Page 25 of 25 _________________________________________________ 1 This laboratory offers commercial calibration and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. re solution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, R is the numerical value of the resolution of the device in microinches, D is the numerical value of the nominal diameter of the device measured in inches. 5 In the statement of CMC, the value is defined as the percentage of reading. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 This scope meets A2LA’s P112 Flexible Scope Policy . 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 Uncertainty is assumed to be 180 deg for all values outside the defined conditions.
26ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1005 West Fayette Street, Suite 4D, Syracuse, NY, 13204, US

43.04812, -76.14742

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.