ABSOLUTE CLARITY & CALIBRATION
76 North Main Street, 06489, Southington, CT, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 6140.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | Steel | to 12 in |
| 2 | - | SteelShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6140.01) Revised 07/23/2025 Page 2 of 2
Parameter/Equipment
Range CMC2, 4 (±) Comments
Toolscopes3 –
Length (X, Y)
Height (Z)
Field of View
Angular
Reticle
Up to 12 in
1 in
2 in
4 in
Up to 1 in
(1 to 2) in
(2 to 4) in
Up to 360°
Up to 1 in
Up to 25 mm
(140 + 8.0L) µin
83 µin
99 µin
150 µin
200 µin
150 µin
140 µin
0.84ʹ
200 µin
3.5 µm
Glass stage micrometer
Gage blocks
Glass stage micrometer
Steel square
Glass stage micrometer
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | to 12 in |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- WTTIAllentown, PA · ~244 kmA2LAShares 1 accredited materialSteel
- Advanced Plastic and Material TestingIthaca, NY · ~313 kmA2LAShares 1 accredited materialSteel
- CalSourceSyracuse, NY · ~313 kmA2LAShares 1 accredited materialSteel
- Westmoreland Mechanical Testing & ResearchYoungstown, PA · ~564 kmA2LAShares 1 accredited materialSteel
- ACR Technical ServicesNewport News, VA · ~585 kmA2LAShares 1 accredited materialSteel
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.