LAB&CO S.R.L.
Via Palermo, 96/98, 95034, Bronte, Italy
Visit website- Accredited standards
- 8
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 15662Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 11731Water quality - Enumeration of Legionella
ISO 14501Milk and milk powder - Determination of aflatoxin M1 content - Clean-up by immunoaffinity chromatography and determination by high-performance liquid chromatography
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique
UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018; CVUA EU RL-SRM QuPPe-PO Vers 12.3 met 1.9 2024
UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018
UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018; AOAC TEMPO BC n 071401 2014; AOAC TEMPO YM n 041001 2010; AFNOR BIO 12/27-02/10; ISO 21528-2:2017; MI 11 REV 03 2022; MI 27 REV 02 2025; AFNOR BIO 12/17-12/05; AFNOR BIO 12/21-12/06; AFNOR BIO 12/13-02/05; AFNOR BIO 12/35-05/13; AFNOR BIO 12/28-04/10; UNI EN ISO 4833-1:2022; AFNOR BIO 12/32-10/11
UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31 pag 55 Met ISS BDA022; Rapporti ISTISAN 2007/31 pag 68 Met ISS BCA023; ISO 11731:2017; MI 21 REV 02 2025; MI 22 REV 02 2025; MI 24 REV 02 2025; MI 23 REV 02 2025; UNI EN ISO 9308-1:2017; MI 08 REV 03 2021; UNI EN ISO 7899-2:2003
UNI CEI EN ISO/IEC 17025:2018; MI 19 REV 01 2023; MI 12 REV 03 2022; MI 18 REV 01 2023; MI 20 REV 01 2023; MI 26 REV 02 2023; UNI EN ISO 14501:2021; MI 16 REV 02 2022; MI 01 Rev 02 2022
ISO 18593:2018
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
6 lines
ISO/IEC 17025
Active01095
Accredited scope, certificate 01095
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31 pag 55 Met ISS BDA022; Rapporti ISTISAN 2007/31 pag 68 Met ISS BCA023; ISO 11731:2017; MI 21 REV 02 2025; MI 22 REV 02 2025; MI 24 REV 02 2025; MI 23 REV 02 2025; UNI EN ISO 9308-1:2017; MI 08 REV 03 2021; UNI EN ISO 7899-2:2003 | Drinking water | See scope document |
| 2 | UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018; CVUA EU RL-SRM QuPPe-PO Vers 12.3 met 1.9 2024 | Food products | - |
| 3 | UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018 | - | - |
| 4 | UNI CEI EN ISO/IEC 17025:2018; UNI EN 15662:2018; AOAC TEMPO BC n 071401 2014; AOAC TEMPO YM n 041001 2010; AFNOR BIO 12/27-02/10; ISO 21528-2:2017; MI 11 REV 03 2022; MI 27 REV 02 2025; AFNOR BIO 12/17-12/05; AFNOR BIO 12/21-12/06; AFNOR BIO 12/13-02/05; AFNOR BIO 12/35-05/13; AFNOR BIO 12/28-04/10; UNI EN ISO 4833-1:2022; AFNOR BIO 12/32-10/11 | Food industry environment samples | See scope document |
| 5 | UNI CEI EN ISO/IEC 17025:2018; MI 19 REV 01 2023; MI 12 REV 03 2022; MI 18 REV 01 2023; MI 20 REV 01 2023; MI 26 REV 02 2023; UNI EN ISO 14501:2021; MI 16 REV 02 2022; MI 01 Rev 02 2022 | Food products | 0.4 to 40 ppm |
| 6 | ISO 18593:2018 | Food products | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- Laboratorio NIROVinchiaturo · ~413 kmACCREDIAShares 6 accredited methods and materialsEN ISO 9308-1:2017ISO 18593:2018UNI EN 15662:2018
- BonassisaLabFoggia · ~417 kmACCREDIAShares 6 accredited methods and materialsEN ISO 9308-1:2017ISO 18593:2018UNI EN 15662:2018
- D'ANIELLO GENNARO & C. S.N.C. DI D'ANIELLO CIROSant'Egidio del Monte Albino · ~330 kmACCREDIAShares 5 accredited methods and materialsISO 18593:2018UNI EN 15662:2018Drinking water
- AGRO.BIOLAB LABORATORY Società a Responsabilità LimitataRutigliano · ~404 kmACCREDIAShares 5 accredited methods and materialsEN ISO 9308-1:2017UNI EN 15662:2018Drinking water
- ARACE LABORATORISan Severo · ~436 kmACCREDIAShares 5 accredited methods and materialsISO 18593:2018UNI EN 15662:2018Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.