FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Japan

UL Japan, Inc. - Kashima EMC

1614 Mushihata, Katori-shi, Chiba-ken, 289-0341, Japan, Chiba-ken, 289-0341, Japan

A2LA|1266.01A2LA|1266.02ISO/IEC 17025Register refreshed 2026-09-25
Certificates
2
Scope items
52
Standards
21
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at UL Japan, Inc. - Kashima EMC?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
1266.01Active
1266.02Active

Accredited standards

21

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 4 (A2LA 1266.01)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

As written on the certificate · Line 4 (A2LA 1266.02)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
As written on the certificate · Line 4 (A2LA 1266.01)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

As written on the certificate · Line 4 (A2LA 1266.02)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 4 (A2LA 1266.01)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

As written on the certificate · Line 21 (A2LA 1266.01)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

As written on the certificate · Line 4 (A2LA 1266.02)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

As written on the certificate · Line 21 (A2LA 1266.02)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 21 (A2LA 1266.01)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

As written on the certificate · Line 21 (A2LA 1266.02)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 22 (A2LA 1266.01)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 22 (A2LA 1266.02)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 13 (A2LA 1266.01)

CISPR 16-1; CISPR 16-1-3; IEC 61000-4-6; CISPR 16-1-4

As written on the certificate · Line 20 (A2LA 1266.01)

IEC 61000-4-6; ISO 11452-4; MIL-STD-461

As written on the certificate · Line 13 (A2LA 1266.02)

CISPR 16-1; CISPR 16-1-3; IEC 61000-4-6; CISPR 16-1-4

As written on the certificate · Line 20 (A2LA 1266.02)

IEC 61000-4-6; ISO 11452-4; MIL-STD-461

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 23 (A2LA 1266.01)

CISPR 16-1-4; ANSI 63.4:2014; ANSI C63.4a; VCCI; CISPR 16-1-4; CISPR 16-1-4:2010; CISPR 16-1-4:2012; CISPR 16-1-4:2017; ANSI C63.25.1(a); IEC 61000-4-8; IEC 61000-4-9

As written on the certificate · Line 23 (A2LA 1266.02)

CISPR 16-1-4; ANSI 63.4:2014; ANSI C63.4a; VCCI; CISPR 16-1-4; CISPR 16-1-4:2010; CISPR 16-1-4:2012; CISPR 16-1-4:2017; ANSI C63.25.1(a); IEC 61000-4-8; IEC 61000-4-9

IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
As written on the certificate · Line 22 (A2LA 1266.01)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 23 (A2LA 1266.01)

CISPR 16-1-4; ANSI 63.4:2014; ANSI C63.4a; VCCI; CISPR 16-1-4; CISPR 16-1-4:2010; CISPR 16-1-4:2012; CISPR 16-1-4:2017; ANSI C63.25.1(a); IEC 61000-4-8; IEC 61000-4-9

As written on the certificate · Line 22 (A2LA 1266.02)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 23 (A2LA 1266.02)

CISPR 16-1-4; ANSI 63.4:2014; ANSI C63.4a; VCCI; CISPR 16-1-4; CISPR 16-1-4:2010; CISPR 16-1-4:2012; CISPR 16-1-4:2017; ANSI C63.25.1(a); IEC 61000-4-8; IEC 61000-4-9

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 22 (A2LA 1266.01)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 22 (A2LA 1266.02)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

IEC 61000-4-15Name not checked yet
As written on the certificate · Line 4 (A2LA 1266.01)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

As written on the certificate · Line 4 (A2LA 1266.02)

IEC 61000-4-15; JIS C 61000-3-2; IEC 61000-3-3; IEC 61000-3-11; IEC 61000-4-2

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
As written on the certificate · Line 22 (A2LA 1266.01)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 22 (A2LA 1266.02)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

IEC 61000-4-34Name not checked yet
As written on the certificate · Line 22 (A2LA 1266.01)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

As written on the certificate · Line 22 (A2LA 1266.02)

IEC 61000-4-5; IEC 61000-4-5:2005; IEC 61000-4-9; IEC 61000-4-11; IEC 61000-4-29; IEC 61000-4-34; CISPR 16-1-4

ISO

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
As written on the certificate · Line 5 (A2LA 1266.01)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

As written on the certificate · Line 12 (A2LA 1266.01)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

As written on the certificate · Line 5 (A2LA 1266.02)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

As written on the certificate · Line 12 (A2LA 1266.02)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
As written on the certificate · Line 5 (A2LA 1266.01)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

As written on the certificate · Line 5 (A2LA 1266.02)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
As written on the certificate · Line 21 (A2LA 1266.01)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

As written on the certificate · Line 21 (A2LA 1266.02)

IEC 61000-4-2; ISO 10605; ISO 10605:2001; RTCA/DO-160; IEC 61000-4-4; IEC 61000-4-4:2004; IEC 61000-4-4

ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 9 (A2LA 1266.01)

CISPR 16-1-2; ISO 11452-4

As written on the certificate · Line 20 (A2LA 1266.01)

IEC 61000-4-6; ISO 11452-4; MIL-STD-461

As written on the certificate · Line 9 (A2LA 1266.02)

CISPR 16-1-2; ISO 11452-4

As written on the certificate · Line 20 (A2LA 1266.02)

IEC 61000-4-6; ISO 11452-4; MIL-STD-461

ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
As written on the certificate · Line 5 (A2LA 1266.01)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

As written on the certificate · Line 5 (A2LA 1266.02)

ISO 7637-2; ISO 7637-2:2004; ISO 7637-3; ISO 16750-2:2012; ISO 16750-2; JASO D 001

Other standards

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
As written on the certificate · Line 15 (A2LA 1266.01)

ANSI C63.5; ANSI C63.5:1998; ANSI C63.5:2006; CISPR 16-1-6; VCCI; ANSI C63.4; CISPR 16-1-4

As written on the certificate · Line 15 (A2LA 1266.02)

ANSI C63.5; ANSI C63.5:1998; ANSI C63.5:2006; CISPR 16-1-6; VCCI; ANSI C63.4; CISPR 16-1-4

CISPR 16-1-2Name not checked yet
As written on the certificate · Line 9 (A2LA 1266.01)

CISPR 16-1-2; ISO 11452-4

As written on the certificate · Line 12 (A2LA 1266.01)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

As written on the certificate · Line 9 (A2LA 1266.02)

CISPR 16-1-2; ISO 11452-4

As written on the certificate · Line 12 (A2LA 1266.02)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

EN 50561-1Name not checked yet
As written on the certificate · Line 12 (A2LA 1266.01)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

As written on the certificate · Line 12 (A2LA 1266.02)

CISPR 16-1-2; CISPR 16-1-2:2014; CISPR 25; ISO 7637-2; ANSI C63.4; Ministry of Internal Affairs & Communications (Japan); EN 50561-1

IEC 61786Name not checked yet
As written on the certificate · Line 24 (A2LA 1266.01)

IEC 61786

As written on the certificate · Line 24 (A2LA 1266.02)

IEC 61786

Scope as published by A2LA

52 lines
A2LA

ISO/IEC 17025

Active

1266.01

The scope document we hold says it is valid until 2027-01-31.

View scope
A2LA

ISO/IEC 17025

Active

1266.02

The scope document we hold says it is valid until 2027-01-31.

View scope

Location

1614 Mushihata, Katori-shi, Chiba-ken, 289-0341, Japan, Chiba-ken, 289-0341, JP

35.65303, 140.05000

Open in Maps

Accreditation data refreshed from the A2LA register on .