What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 51 standard numbers and the 33 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI13
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-31
ETSI EN 301 489-33
ETSI EN 301 893
ETSI EN 302 065-1
ETSI EN 302 195
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+2 national
National versions in the same scope
AS/NZS 4251.2identical to it
AS/NZS 61000.6.4identical to it
IEC 60601 series7
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-24
IEC 60601-2-25
IEC 60601-2-26
IEC 60601-2-27
IEC 60601-2-28Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
IEC 60601-2-49
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
AS/NZS CISPR 11national version with changes
CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers+1 national
National versions in the same scope
AS/NZS CISPR 12national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national
National versions in the same scope
AS/NZS CISPR 35probably the same standard; matched by number only
IEC5
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-2
IEC 62061
ISO3
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 13766Earth-moving machinery - Electromagnetic compatibilityExclusion
Limits written next to it
Construction Equipment ISO 13766 (excluding section 5.10)
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteriaExclusion
Limits written next to it
Agriculture / Forestry ISO 14982 (excluding section 6.8)
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 301 893; ETSI EN 302 065-1; ETSI EN 302 195; AS/NZS 4268; EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-8; EN 61000-4-11; EN 55014-2; EN 55035; EN 61000-6-1; EN 61000-6-2; BS EN 61000-4-2; BS EN 61000-4-3; BS EN 61000-4-4; BS EN 61000-4-5; BS EN 61000-4-6; BS EN 61000-4-8; BS EN 61000-4-11; BS EN 55014-2; BS EN 55035; BS EN 61000-6-1; BS EN 61000-6-2; AS/NZS CISPR 14.2; AS/NZS CISPR 35; AS/NZS 61000.6.1; AS/NZS 61000.6.2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC CISPR 14-2; IEC CISPR 35; IEC 61000-6-1; IEC 61000-6-2
IEC CISPR 11; IEC CISPR 12; IEC CISPR 14-1; IEC CISPR 32; IEC 61000-6-3; IEC 61000-6-4; EN 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-2; EN 61000-3-3; AS/NZS 61000.3.3; IEC 61000-3-3; 47 CFR, Part 15 C; ANSI C63.10:2013; 47 CFR, Part 15 E; KDB 905462 D02 (v02); 47 CFR, Part 15 F; ANSI C63.10:2020; DA 00-705; RSS-GEN; RSS-102; RSS-102.NS.MEAS; RSS-210; RSS-216; RSS-220; RSS-243; RSS-247; RSS-248; RSS-310; SPR-002
EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4; AS/NZS 61000.6.1; AS/NZS 61000.6.2; AS/NZS 61000.6.3; AS/NZS 61000.6.4; AS/NZS 4251.1; AS/NZS 4251.2; IEC CISPR 11; EN 55011; AS/NZS CISPR 11; IEC CISPR 12; EN 55012; AS/NZS CISPR 12; IEC CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1; IEC CISPR 14-2; EN 55014-2; AS/NZS CISPR 14.2; IEC CISPR 32; EN 55032; AS/NZS CISPR 32; IEC CISPR 35; EN 55035; AS/NZS CISPR 35; IEC/EN/BS EN 61326-1; BS EN 61326-2-6; BS EN 50121-3-2; IEC/EN/BS EN 61800-3; IEC/EN/BS EN 61800-5-2; IEC/EN/BS EN 62061; ISO 14982; ISO 13766; ISO 10605; IEC 60601-1-2; EN 60601-1-2; IEC 60601-2-24; EN 60601-2-24; IEC 60601-2-25; EN 60601-2-25; IEC 60601-2-26; EN 60601-2-26; IEC 60601-2-27; EN 60601-2-28; IEC 60601-2-49; EN 60601-2-49; AIM 7351731
FCC (US) 47 CFR, Part 15 B; 47 CFR, Part 18; ICES-001; ICES-002; ICES-003; CAN/CSA-CEI/IEC CISPR 11; EN 55011; EN 55012; EN 55014-1; EN 55032; EN 61000-6-3; EN 61000-6-4; BS EN 55011; BS EN 55012; BS EN 55014-1; BS EN 55032; BS EN 61000-6-3; BS EN 61000-6-4; AS CISPR 11; AS/NZS CISPR 12; AS/NZS CISPR 14.1; AS/NZS 61000.6.3; AS/NZS 61000.6.4; AS/NZS 4251.1; AS/NZS 4251.2; ANSI C63.4:2014; FCC MP-5:1986
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; FCC KDB 905462 D02 (v02)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1255.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 1255.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FCC (US) 47 CFR, Part 15 B; 47 CFR, Part 18; ICES-001; ICES-002; ICES-003; CAN/CSA-CEI/IEC CISPR 11; EN 55011; EN 55012; EN 55014-1; EN 55032; EN 61000-6-3; EN 61000-6-4; BS EN 55011; BS EN 55012; BS EN 55014-1; BS EN 55032; BS EN 61000-6-3; BS EN 61000-6-4; AS CISPR 11; AS/NZS CISPR 12; AS/NZS CISPR 14.1; AS/NZS 61000.6.3; AS/NZS 61000.6.4; AS/NZS 4251.1; AS/NZS 4251.2; ANSI C63.4:2014; FCC MP-5:1986 | - | - |
| 2 | IEC CISPR 11; IEC CISPR 12; IEC CISPR 14-1; IEC CISPR 32; IEC 61000-6-3; IEC 61000-6-4; EN 61000-3-2; AS/NZS 61000.3.2; IEC 61000-3-2; EN 61000-3-3; AS/NZS 61000.3.3; IEC 61000-3-3; 47 CFR, Part 15 C; ANSI C63.10:2013; 47 CFR, Part 15 E; KDB 905462 D02 (v02); 47 CFR, Part 15 F; ANSI C63.10:2020; DA 00-705; RSS-GEN; RSS-102; RSS-102.NS.MEAS; RSS-210; RSS-216; RSS-220; RSS-243; RSS-247; RSS-248; RSS-310; SPR-002 | - | to 40 GHz |
| 3 | ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 328; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-31; ETSI EN 301 489-33; ETSI EN 301 893; ETSI EN 302 065-1; ETSI EN 302 195; AS/NZS 4268; EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-8; EN 61000-4-11; EN 55014-2; EN 55035; EN 61000-6-1; EN 61000-6-2; BS EN 61000-4-2; BS EN 61000-4-3; BS EN 61000-4-4; BS EN 61000-4-5; BS EN 61000-4-6; BS EN 61000-4-8; BS EN 61000-4-11; BS EN 55014-2; BS EN 55035; BS EN 61000-6-1; BS EN 61000-6-2; AS/NZS CISPR 14.2; AS/NZS CISPR 35; AS/NZS 61000.6.1; AS/NZS 61000.6.2; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; IEC CISPR 14-2; IEC CISPR 35; IEC 61000-6-1; IEC 61000-6-2 | - | - |
| 4 | EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; EN 61000-6-4; AS/NZS 61000.6.1; AS/NZS 61000.6.2; AS/NZS 61000.6.3; AS/NZS 61000.6.4; AS/NZS 4251.1; AS/NZS 4251.2; IEC CISPR 11; EN 55011; AS/NZS CISPR 11; IEC CISPR 12; EN 55012; AS/NZS CISPR 12; IEC CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1; IEC CISPR 14-2; EN 55014-2; AS/NZS CISPR 14.2; IEC CISPR 32; EN 55032; AS/NZS CISPR 32; IEC CISPR 35; EN 55035; AS/NZS CISPR 35; IEC/EN/BS EN 61326-1; BS EN 61326-2-6; BS EN 50121-3-2; IEC/EN/BS EN 61800-3; IEC/EN/BS EN 61800-5-2; IEC/EN/BS EN 62061; ISO 14982; ISO 13766; ISO 10605; IEC 60601-1-2; EN 60601-1-2; IEC 60601-2-24; EN 60601-2-24; IEC 60601-2-25; EN 60601-2-25; IEC 60601-2-26; EN 60601-2-26; IEC 60601-2-27; EN 60601-2-28; IEC 60601-2-49; EN 60601-2-49; AIM 7351731 | - | - |
| 5 | ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2020; FCC KDB 905462 D02 (v02) | - | to 40000 MHz |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
EZURIO
Cedarburg, WI
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 25th day of March 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1255.01
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- UL LLCNorthbrook, IL · ~131 kmA2LAShares 3 accredited test methodsANSI C63.4:2014ETSI EN 300 220-1ICES-001
- TUV SUD AmericaNew Brighton, MN · ~460 kmA2LAShares 2 accredited test methodsANSI C63.4:2014EN 61000-6-1
- EUROFINS ELECTRICAL AND ELECTRONIC TESTING NAAustin, TX · ~1,686 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- Intertek Testing Services NALake Forest, CA · ~2,781 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
- SGS North AmericaSan Diego, CA · ~2,795 kmA2LAShares 2 accredited test methodsETSI EN 300 220-1ICES-001
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.