United States

Interface

7401 E. Butherus Drive, 85260, Scottsdale, AZ, United States

Visit website
A2LA 1991.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1991.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1991.01) 10/24/2024 Page 2 of 2 II. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Force – Load Cells, Force Transducers (200 to 240 000) lbf (100 to 1100) lbf (240 000 to 1 000 000) lbf (1 to 500) lbf (25 to 1100) lbf (10 to 550) lbf (2 to 50) gf (25 to 2000) gf 0.035 % 0.05 % 0.041 % 0.04 % 0.03 % 0.021 % 0.04 % 0.03 % Load cells Free weights Actuated weights Actuated weights (stainless steel) Free weights Torque – Torque Transducers (0.022 to 0.11) lbf∙in (0.09 to 0.18) lbf∙in (0.20 to 100) lbf∙in (2.2 to 250) lbf∙in (8.8 to 177) lbf∙in (40 to 2200) lbf∙in (1700 to 50 000) lbf∙in (3500 to 50 000) lbf∙in (5300 to 100 000) lbf∙in 0.37 % 0.1 % 0.055 % 0.042 % 0.05 % 0.04 % 0.11 % 0.07 % 0.07 % Torque arm and weights Transducer comparison ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC a % denotes a percent of reading unless otherwise noted. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7401 E. Butherus Drive, Scottsdale, AZ, 85260, US

33.49422, -111.92602

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.