Integrity Calibration Services
1701 Oak Hill Road Suite H, 47711, Evansville, IN, United States
Visit website- Scope lines
- 12
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 2358.01 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 29 to 329.99 µA |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 2 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
(33 to 329.999) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
Toroidal/Non-Toroidal:
(16.5 to 1025) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
(100 to 440) Hz
0.21 % + 21 µA
0.11 % + 21 µA
0.047 % + 21 µA
0.12 % + 51 µA
0.24 % + 100 µA
0.47 % + 200 µA
0.21 % + 110 µA
0.058 % + 110 µA
0.7 % + 1 mA
2.9 % + 5 mA
0.21 % + 110 µA
0.07 % + 110 µA
0.69 % + 1.0 mA
2.9 % + 5.0 mA
0.07 % + 2.1 mA
0.12 % + 2.1 mA
3.5 % + 2.1 mA
0.14 % + 5.1 mA
0.18 % + 5.1 mA
3.5 % + 5.1 mA
1.2 % + 1 A
1.7 % + 1.2 A
Fluke 5502A
Fluke 5502A w/50:1
coil
AC Current – Measure3
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.058 % + 20 nA
0.082 % + 20 nA
0.47 % + 20 nA
0.035 % + 200 nA
0.082 % + 200 nA
0.47 % + 200 nA
0.035 % + 2 µA
0.082 % + 2 µA
0.47 % + 2 µA
Fluke 8508A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 3 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure3
(cont)
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.034 % + 20 µA
0.073 % + 20 µA
0.072 % + 200 µA
0.085 % + 200 µA
0.35 % + 200 µA
0.095 % + 2 mA
0.29 % + 2 mA
Fluke 8508A
AC Voltage – Measure3
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.017 % + 4.1 µV
0.014 % + 4.1 µV
0.014 % + 2.1 µV
0.016 % + 4.1 µV
0.04 % + 8.1 µV
0.089 % + 20 µV
0.014 % + 21 µV
0.011 % + 21 µV
0.010 % + 21 µV
0.013 % + 21 µV
0.026 % + 41 µV
0.066 % + 200 µV
0.35 % + 2 mV
1.2 % + 20 mV
0.014 % + 210 µV
0.011 % + 210 µV
0.009 % + 210 µV
0.013 % + 210 µV
0.026 % + 410 µV
0.066 % + 2 mV
0.35 % + 20 mV
1.2 % + 200 mV
0.014 % + 2.1 mV
0.011 % + 2.1 mV
92 µV/V + 2.1 mV
0.013 % + 2.1 mV
0.026 % + 4.1 mV
0.066 % + 20 mV
0.35 % + 200 mV
1.2 % + 2 V
Fluke 8508A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 4 of 11
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(cont)
(200 to 1050) V
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.019 % + 21 mV
0.014 % + 21 mV
0.027 % + 41 mV
0.067 % + 200 mV
Fluke 8508A
AC Voltage – Generate3
(1 to 32.999) mV
(33 to 329.999) mV
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.18 % + 21 µV
0.12 % + 21 µV
0.18 % + 21 µV
0.23 % + 21 µV
0.41 % + 34 µV
1.2 % + 61 µV
0.058 % + 21 µV
0.035 % + 21 µV
0.081 % + 21 µV
0.12 % + 41 µV
0.27 % + 170 µV
0.58 % + 330 µV
0.058 % + 67 µV
0.035 % + 67 µV
0.081 % + 67 µV
0.12 % + 67 µV
0.27 % + 210 µV
0.58 % + 910 µV
0.058 % + 870 µV
0.035 % + 670 µV
0.081 % + 670 µV
0.12 % + 670 µV
0.27 % + 2.1 mV
0.058 % + 3.7 mV
0.093 % + 9.7 mV
0.11 % + 9.7 mV
0.14 % + 9.7 mV
0.28 % + 81 mV
0.058 % + 27 mV
0.093 % + 27 mV
0.11 % + 27 mV
Fluke 5502A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 5 of 11
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Generate3
Up to 329.9999 mV
330 mV to 3.299 999 V
(3.3 to 32.999 99) V
(33 to 329.9999) V
(330 to 1020) V
0.007 % + 3.1 µV
0.006 % + 6.2 µV
0.006 % + 62 µV
0.007 % + 0.62 mV
0.007 % + 2.7 mV
Fluke 5502A
DC Current – Generate3
Toroidal/Non-
Toroidal
Up to 329.999 µA
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(16.5 to 1025) A
0.018 % + 21 nA
0.012 % + 57 nA
0.012 % + 320 nA
0.012 % + 3.2 µA
0.044 % + 51 µA
0.044 % + 56 µA
0.07 % + 570 µA
0.12 % + 870 µA
0.59 % + 0.54 A
Fluke 5502A
Fluke 5502A w/ 50:1
coil
DC Voltage – Measure3
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1050) V
0.0009 % + 0.1 µV
0.0008 % + 0.4 µV
0.0008 % + 4 µV
0.0009 % + 40 µV
0.001 % + 0.5 mV
Fluke 8508A
Capacitance – Generate3
(0.22 to 1.0999) nF
(1.1 to 3.299) nF
(3.3 to 10.999) nF
(11 to 32.999) nF
(33 to 109.999) nF
(110 to 329.99) nF
(0.33 to 1.0999) µF
(1.1 to 3.2999) µF
(3.3 to 10.999) µF
(11 to 32.999) µF
(33 to 109.99) µF
(110 to 329.99) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.999) mF
(11 to 32.999) mF
(33 to 110.0) mF
0.59 % + 11 pF
0.59 % + 16 pF
0.30 % + 16 pF
0.30 % + 160 pF
0.30 % + 170 pF
0.30 % + 910 pF
0.30 % + 1.7 nF
0.30 % + 9.1 nF
0.30 % + 17 nF
0.47 % + 91 nF
0.53 % + 170 nF
0.53 % + 910 nF
0.53 % + 1.7 µF
0.53 % + 9.1 µF
0.53 % + 17 µF
0.87 % + 91 µF
1.3 % + 220 µF
Fluke 5502A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 6 of 11
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Measure3
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
0.0018 % + 410 pA
0.0018 % + 4.1 nA
0.0025 % + 41 nA
0.0062 % + 810 nA
0.019 % + 16 µA
0.047 % + 0.41 mA
Fluke 8508A
Resistance – Generate3
Up to 10.999 Ω
(11 to 32.999) Ω
(33 to 109.999) Ω
(110 to 329.999) Ω
330 Ω to 1.099 99 kΩ
(1.1 to 3.299 99) kΩ
(3.3 to 10.9999) kΩ
(11 to 32.9999) kΩ
(33 to 109.999) kΩ
(110 to 329.999) kΩ
330 kΩ to 1.099 99 MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
0.015 % + 1.7 mΩ
0.014 % + 2.2 mΩ
0.011 % + 2.1 mΩ
0.011 % + 3.2 mΩ
0.011 % + 8.6 mΩ
0.011 % + 32 mΩ
0.011 % + 86 mΩ
0.011 % + 0.32 Ω
0.013 % + 0.86 Ω
0.014 % + 3.2 Ω
0.018 % + 8.6 Ω
0.018 % + 42 Ω
0.07 % + 120 Ω
0.12 % + 2.7 kΩ
0.58 % + 3.7 kΩ
0.58 % + 110 kΩ
1.8 % + 0.51 MΩ
Fluke 5502A
Resistance – Measure3
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
0.0055 % + 4 µΩ
0.0052 % + 15 µΩ
0.002 % + 51 µΩ
0.001 % + 510 µΩ
0.0014 % + 5.1 mΩ
0.001 % + 51 mΩ
0.022 % + 1 Ω
0.0024 % + 10 Ω
0.023 % + 1 kΩ
0.068 % + 0.1 MΩ
0.19 % + 10 MΩ
Fluke 8508A
RTD – Measure3
Up to 199.99 Ω
(200 to 1999.9) Ω
0.0052 % + 0.15 mΩ
0.001 % + 0.57 mΩ
Fluke 8508A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 7 of 11
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicating Systems3
–
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 385, 1000 Ω
Ni 385, 120 Ω
Cu 427, 10 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 630) °C
(630 to 800) °C
(-80 to 630) °C
(-200 to 600) °C
(-80 to 260) °C
(-100 to 260) °C
0.07 °C
0.09 °C
0.12 °C
0.15 °C
0.27 °C
0.18 °C
0.13 °C
0.19 °C
0.36 °C
Fluke 5502A
Electrical Calibration of
Thermocouples &
Thermocouple Indicating
Systems3 –
Type B
(250 to < 350) °C
(350 to < 445) °C
(445 to < 580) °C
(580 to < 750) °C
(750 to < 1000) °C
(1000 to 1820) °C
1.3 °C
0.99 °C
0.84 °C
0.73 °C
0.66 °C
0.61 °C
Ectron 1140A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 8 of 11
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouples &
Thermocouple Indicating
Systems
3 – (cont)
Type C
Type E
Type J
Type K
Type N
(0 to < 250) °C
(250 to < 1000) °C
(1000 to < 1500) °C
(1500 to < 1800) °C
(1800 to < 2000) °C
(2000 to < 2250) °C
(2250 to 2315.56) °C
(-270 to < -245) °C
(-245 to < -195) °C
(-195 to < -155) °C
(-155 to < -90) °C
(-90 to < 15) °C
(15 to < 890) °C
(890 to 1000) °C
(-210 to < -180) °C
(-180 to < -120) °C
(-120 to < -50) °C
(-50 to < 990) °C
(990 to 1200) °C
(-270 to < -255) °C
(-255 to < -195) °C
(-195 to < -115) °C
(-115 to < -55) °C
(-55 to < 1000) °C
(1000 to 1372) °C
(-270 to < -260) °C
(-260 to < -200) °C
(-200 to < -140) °C
(-140 to < -70) °C
(-70 to < 25) °C
(25 to < 160) °C
(160 to 1300) °C
0.55 °C
0.54 °C
0.55 °C
0.56 °C
0.57 °C
0.61 °C
0.63 °C
1.4 °C
0.22 °C
0.13 °C
0.11 °C
0.094 °C
0.077 °C
0.09 °C
0.15 °C
0.13 °C
0.11 °C
0.096 °C
0.092 °C
2.6 °C
0.82 °C
0.16 °C
0.13 °C
0.098 °C
0.14 °C
5.8 °C
1.2 °C
0.29 °C
0.21 °C
0.18 °C
0.16 °C
0.14 °C
Ectron 1140A | to 2315.56 °C |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 9 of 11
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouples &
Thermocouple Indicating
Systems
3 – (cont)
Type R
Type S
Type T
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 160) °C
(160 to < 380) °C
(380 to < 775) °C
(775 to 1768.1) °C
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 105) °C
(105 to < 310) °C
(310 to < 615) °C
(615 to 1768.1) °C
(-270 to < -255) °C
(-255 to < -240) °C
(-240 to < -210) °C
(-210 to < -150) °C
(-150 to < -40) °C
(-40 to < 100) °C
(100 to 400) °C
0.91 °C
0.81 °C
0.69 °C
0.41 °C
0.35 °C
0.32 °C
0.83 °C
0.78 °C
0.63 °C
0.57 °C
0.42 °C
0.39 °C
2.1 °C
0.59 °C
0.37 °C
0.25 °C
0.19 °C
0.14 °C
0.13 °C
Ectron 1140A
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature – Measuring
Equipment & Measure3
Infrared
(-30 to 100) °C
(100 to 425) °C
(425 to 650) °C
(650 to 1000) °C
(1000 to 1100) °C
(1100 to 1200) °C
(50 to 500) °C
0.08 °C
0.07 °C
0.09 °C
1.2 °C
1.3 °C
1.6 °C
1.3 °C + 1 % rdg
Emissivity 0.95
Hart 5626, Fluke 8508A,
Hart 7103 fluid bath
Hart 5626, Fluke 8508A,
Hart 9173 metrology well
Hart 5650 type S
reference standard, Fluke
8508A, furnace
Hart 9132 with PRT
&Fluke 8508A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 10 of 11
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Relative Humidity –
Measuring Equipment,
Fixed Points3
11 % RH
33 % RH
75 % RH
97 % RH
2.1 % RH
2.4 % RH
2.8 % RH
3.7 % RH
Saturated salts
Relative Humidity –
Measure3
(10 to 90) % RH
(90 to 95) % RH
1.9 % RH
2.5 % RH
Vaisala MI70 &
HMP76
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Frequency – Measuring
Equipment3
10 Hz to 10 kHz
10 kHz to 2 MHz
0.0018 % + 7 mHz
0.014 % + 620 mHz
Fluke 5502A
Frequency – Measure3
1 Hz to 225 MHz
2.4 µHz/Hz + 30 µHz
Agilent 53132A
____________________________________________
1 This laboratory offers commercial calibration and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2358.01) 09/30/2025 Page 11 of 11
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- JM Test SystemsMattoon, IL · ~182 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- K & S AssociatesNashville, TN · ~213 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Endress+HauserGreenwood, IN · ~222 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Co., LLC - LEBANONLebanon, TN · ~227 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Magnetic InstrumentationIndianapolis, IN · ~234 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.