Integrity Calibration Services

1701 Oak Hill Road Suite H, 47711, Evansville, IN, United States

Visit website
A2LA 2358.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 2358.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-29 to 329.99 µA
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 2 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A Toroidal/Non-Toroidal: (16.5 to 1025) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz (100 to 440) Hz 0.21 % + 21 µA 0.11 % + 21 µA 0.047 % + 21 µA 0.12 % + 51 µA 0.24 % + 100 µA 0.47 % + 200 µA 0.21 % + 110 µA 0.058 % + 110 µA 0.7 % + 1 mA 2.9 % + 5 mA 0.21 % + 110 µA 0.07 % + 110 µA 0.69 % + 1.0 mA 2.9 % + 5.0 mA 0.07 % + 2.1 mA 0.12 % + 2.1 mA 3.5 % + 2.1 mA 0.14 % + 5.1 mA 0.18 % + 5.1 mA 3.5 % + 5.1 mA 1.2 % + 1 A 1.7 % + 1.2 A Fluke 5502A Fluke 5502A w/50:1 coil AC Current – Measure3 Up to 200 µA 200 µA to 2 mA (2 to 20) mA 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.058 % + 20 nA 0.082 % + 20 nA 0.47 % + 20 nA 0.035 % + 200 nA 0.082 % + 200 nA 0.47 % + 200 nA 0.035 % + 2 µA 0.082 % + 2 µA 0.47 % + 2 µA Fluke 8508A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 3 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure3 (cont) (20 to 200) mA 200 mA to 2 A (2 to 20) A 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.034 % + 20 µA 0.073 % + 20 µA 0.072 % + 200 µA 0.085 % + 200 µA 0.35 % + 200 µA 0.095 % + 2 mA 0.29 % + 2 mA Fluke 8508A AC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.017 % + 4.1 µV 0.014 % + 4.1 µV 0.014 % + 2.1 µV 0.016 % + 4.1 µV 0.04 % + 8.1 µV 0.089 % + 20 µV 0.014 % + 21 µV 0.011 % + 21 µV 0.010 % + 21 µV 0.013 % + 21 µV 0.026 % + 41 µV 0.066 % + 200 µV 0.35 % + 2 mV 1.2 % + 20 mV 0.014 % + 210 µV 0.011 % + 210 µV 0.009 % + 210 µV 0.013 % + 210 µV 0.026 % + 410 µV 0.066 % + 2 mV 0.35 % + 20 mV 1.2 % + 200 mV 0.014 % + 2.1 mV 0.011 % + 2.1 mV 92 µV/V + 2.1 mV 0.013 % + 2.1 mV 0.026 % + 4.1 mV 0.066 % + 20 mV 0.35 % + 200 mV 1.2 % + 2 V Fluke 8508A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 4 of 11 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (cont) (200 to 1050) V (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.019 % + 21 mV 0.014 % + 21 mV 0.027 % + 41 mV 0.067 % + 200 mV Fluke 8508A AC Voltage – Generate3 (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.18 % + 21 µV 0.12 % + 21 µV 0.18 % + 21 µV 0.23 % + 21 µV 0.41 % + 34 µV 1.2 % + 61 µV 0.058 % + 21 µV 0.035 % + 21 µV 0.081 % + 21 µV 0.12 % + 41 µV 0.27 % + 170 µV 0.58 % + 330 µV 0.058 % + 67 µV 0.035 % + 67 µV 0.081 % + 67 µV 0.12 % + 67 µV 0.27 % + 210 µV 0.58 % + 910 µV 0.058 % + 870 µV 0.035 % + 670 µV 0.081 % + 670 µV 0.12 % + 670 µV 0.27 % + 2.1 mV 0.058 % + 3.7 mV 0.093 % + 9.7 mV 0.11 % + 9.7 mV 0.14 % + 9.7 mV 0.28 % + 81 mV 0.058 % + 27 mV 0.093 % + 27 mV 0.11 % + 27 mV Fluke 5502A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 5 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 Up to 329.9999 mV 330 mV to 3.299 999 V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1020) V 0.007 % + 3.1 µV 0.006 % + 6.2 µV 0.006 % + 62 µV 0.007 % + 0.62 mV 0.007 % + 2.7 mV Fluke 5502A DC Current – Generate3 Toroidal/Non- Toroidal Up to 329.999 µA 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (16.5 to 1025) A 0.018 % + 21 nA 0.012 % + 57 nA 0.012 % + 320 nA 0.012 % + 3.2 µA 0.044 % + 51 µA 0.044 % + 56 µA 0.07 % + 570 µA 0.12 % + 870 µA 0.59 % + 0.54 A Fluke 5502A Fluke 5502A w/ 50:1 coil DC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V 0.0009 % + 0.1 µV 0.0008 % + 0.4 µV 0.0008 % + 4 µV 0.0009 % + 40 µV 0.001 % + 0.5 mV Fluke 8508A Capacitance – Generate3 (0.22 to 1.0999) nF (1.1 to 3.299) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110.0) mF 0.59 % + 11 pF 0.59 % + 16 pF 0.30 % + 16 pF 0.30 % + 160 pF 0.30 % + 170 pF 0.30 % + 910 pF 0.30 % + 1.7 nF 0.30 % + 9.1 nF 0.30 % + 17 nF 0.47 % + 91 nF 0.53 % + 170 nF 0.53 % + 910 nF 0.53 % + 1.7 µF 0.53 % + 9.1 µF 0.53 % + 17 µF 0.87 % + 91 µF 1.3 % + 220 µF Fluke 5502A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 6 of 11 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Measure3 Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 0.0018 % + 410 pA 0.0018 % + 4.1 nA 0.0025 % + 41 nA 0.0062 % + 810 nA 0.019 % + 16 µA 0.047 % + 0.41 mA Fluke 8508A Resistance – Generate3 Up to 10.999 Ω (11 to 32.999) Ω (33 to 109.999) Ω (110 to 329.999) Ω 330 Ω to 1.099 99 kΩ (1.1 to 3.299 99) kΩ (3.3 to 10.9999) kΩ (11 to 32.9999) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ 330 kΩ to 1.099 99 MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 0.015 % + 1.7 mΩ 0.014 % + 2.2 mΩ 0.011 % + 2.1 mΩ 0.011 % + 3.2 mΩ 0.011 % + 8.6 mΩ 0.011 % + 32 mΩ 0.011 % + 86 mΩ 0.011 % + 0.32 Ω 0.013 % + 0.86 Ω 0.014 % + 3.2 Ω 0.018 % + 8.6 Ω 0.018 % + 42 Ω 0.07 % + 120 Ω 0.12 % + 2.7 kΩ 0.58 % + 3.7 kΩ 0.58 % + 110 kΩ 1.8 % + 0.51 MΩ Fluke 5502A Resistance – Measure3 Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 0.0055 % + 4 µΩ 0.0052 % + 15 µΩ 0.002 % + 51 µΩ 0.001 % + 510 µΩ 0.0014 % + 5.1 mΩ 0.001 % + 51 mΩ 0.022 % + 1 Ω 0.0024 % + 10 Ω 0.023 % + 1 kΩ 0.068 % + 0.1 MΩ 0.19 % + 10 MΩ Fluke 8508A RTD – Measure3 Up to 199.99 Ω (200 to 1999.9) Ω 0.0052 % + 0.15 mΩ 0.001 % + 0.57 mΩ Fluke 8508A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 7 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicating Systems3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 385, 1000 Ω Ni 385, 120 Ω Cu 427, 10 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 630) °C (630 to 800) °C (-80 to 630) °C (-200 to 600) °C (-80 to 260) °C (-100 to 260) °C 0.07 °C 0.09 °C 0.12 °C 0.15 °C 0.27 °C 0.18 °C 0.13 °C 0.19 °C 0.36 °C Fluke 5502A Electrical Calibration of Thermocouples & Thermocouple Indicating Systems3 – Type B (250 to < 350) °C (350 to < 445) °C (445 to < 580) °C (580 to < 750) °C (750 to < 1000) °C (1000 to 1820) °C 1.3 °C 0.99 °C 0.84 °C 0.73 °C 0.66 °C 0.61 °C Ectron 1140A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 8 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Thermocouple Indicating Systems 3 – (cont) Type C Type E Type J Type K Type N (0 to < 250) °C (250 to < 1000) °C (1000 to < 1500) °C (1500 to < 1800) °C (1800 to < 2000) °C (2000 to < 2250) °C (2250 to 2315.56) °C (-270 to < -245) °C (-245 to < -195) °C (-195 to < -155) °C (-155 to < -90) °C (-90 to < 15) °C (15 to < 890) °C (890 to 1000) °C (-210 to < -180) °C (-180 to < -120) °C (-120 to < -50) °C (-50 to < 990) °C (990 to 1200) °C (-270 to < -255) °C (-255 to < -195) °C (-195 to < -115) °C (-115 to < -55) °C (-55 to < 1000) °C (1000 to 1372) °C (-270 to < -260) °C (-260 to < -200) °C (-200 to < -140) °C (-140 to < -70) °C (-70 to < 25) °C (25 to < 160) °C (160 to 1300) °C 0.55 °C 0.54 °C 0.55 °C 0.56 °C 0.57 °C 0.61 °C 0.63 °C 1.4 °C 0.22 °C 0.13 °C 0.11 °C 0.094 °C 0.077 °C 0.09 °C 0.15 °C 0.13 °C 0.11 °C 0.096 °C 0.092 °C 2.6 °C 0.82 °C 0.16 °C 0.13 °C 0.098 °C 0.14 °C 5.8 °C 1.2 °C 0.29 °C 0.21 °C 0.18 °C 0.16 °C 0.14 °C Ectron 1140A
to 2315.56 °C
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 9 of 11 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Thermocouple Indicating Systems 3 – (cont) Type R Type S Type T (-50 to < -30) °C (-30 to < 45) °C (45 to < 160) °C (160 to < 380) °C (380 to < 775) °C (775 to 1768.1) °C (-50 to < -30) °C (-30 to < 45) °C (45 to < 105) °C (105 to < 310) °C (310 to < 615) °C (615 to 1768.1) °C (-270 to < -255) °C (-255 to < -240) °C (-240 to < -210) °C (-210 to < -150) °C (-150 to < -40) °C (-40 to < 100) °C (100 to 400) °C 0.91 °C 0.81 °C 0.69 °C 0.41 °C 0.35 °C 0.32 °C 0.83 °C 0.78 °C 0.63 °C 0.57 °C 0.42 °C 0.39 °C 2.1 °C 0.59 °C 0.37 °C 0.25 °C 0.19 °C 0.14 °C 0.13 °C Ectron 1140A II. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measuring Equipment & Measure3 Infrared (-30 to 100) °C (100 to 425) °C (425 to 650) °C (650 to 1000) °C (1000 to 1100) °C (1100 to 1200) °C (50 to 500) °C 0.08 °C 0.07 °C 0.09 °C 1.2 °C 1.3 °C 1.6 °C 1.3 °C + 1 % rdg Emissivity 0.95 Hart 5626, Fluke 8508A, Hart 7103 fluid bath Hart 5626, Fluke 8508A, Hart 9173 metrology well Hart 5650 type S reference standard, Fluke 8508A, furnace Hart 9132 with PRT &Fluke 8508A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 10 of 11 Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity – Measuring Equipment, Fixed Points3 11 % RH 33 % RH 75 % RH 97 % RH 2.1 % RH 2.4 % RH 2.8 % RH 3.7 % RH Saturated salts Relative Humidity – Measure3 (10 to 90) % RH (90 to 95) % RH 1.9 % RH 2.5 % RH Vaisala MI70 & HMP76 III. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency – Measuring Equipment3 10 Hz to 10 kHz 10 kHz to 2 MHz 0.0018 % + 7 mHz 0.014 % + 620 mHz Fluke 5502A Frequency – Measure3 1 Hz to 225 MHz 2.4 µHz/Hz + 30 µHz Agilent 53132A ____________________________________________ 1 This laboratory offers commercial calibration and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2358.01) 09/30/2025 Page 11 of 11 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1701 Oak Hill Road Suite H, Evansville, IN, 47711, US

37.97049, -87.57156

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.