Registers refreshed 2026-11-20.See refresh dates
United States

Magnetic Instrumentation

8431 Castlewood Drive, 46250, Indianapolis, IN, United States

Visit website
A2LA 1462.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1462.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 2 of 4 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Measure (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 750) V 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 0.078 % + 40 µV 0.076 % + 0.3 mV 0.075 % + 3 mV 0.075 % + 30 mV 0.081 % + 230 mV Agilent 34401A DMM AC Current – Measure (0 to 1) A (0 to 3) A 10 Hz to 5 kHz 10 Hz to 5 kHz 0.14 % + 0.40 mA 0.24 % + 1.8 mA Agilent 34401A DMM II. Magnetic Quantities Parameter/Equipment Range CMC2, 3 (±) Comments Magnetic Flux Density – Hall Probe Meter w/ Probe MI Probe Stations Reference Magnets (0 to 100) G (200 to 500) G (600 to 2000) G (3000 to 10 000) G (10 000 to 20 000) G (20 000 to 30 000) G (30 000 to 100 000) G (430 to 1300) G (900 to 2600) G (1700 to 5200) G (7000 to 21 000) G (0 to 100) G (100 to 500) G (500 to 2000) G (2000 to 10 000) G 0.38 % + 0.02 G 0.36 % + 0.1 G 0.35 % + 0.4 G 0.35 % + 2 G 0.35 % + 4 G 1.2 % + 10 G 1.2 % + 20 G 0.009 % + 0.12 G 0.044 % + 1.2 G 0.022 % + 1.2 G 0.055 % + 12 G 0.47 % + 0.05 G 0.37 % + 0.05 G 0.38 % + 0.06 G 0.37 % + 0.94 G MI probe calibration station Metrolab PT 2025 NMR system MI 2100 gaussmeter
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 3 of 4 Parameter/Equipment Range CMC2, 3 (±) Comments DC Magnetic Flux – Fluxmeters (0 to 100) kMT (100 to 200) kMT (200 to 500) kMT (0.5 to 1) MMT (1 to 2) MMT (2 to 5) MMT (5 to 10) MMT (10 to 20) MMT (20 to 50) MMT (50 to 100) MMT 0.021 % + 0.075 kMT 0.035 % + 0.11 kMT 0.048 % + 0.1 kMT 0.049 % + 0.2 kMT 0.055 % + 0.16 kMT 0.048 % + 0.99 kMT 0.052 % + 1.3 kMT 0.054 % + 2.1 kMT 0.057 % + 2.5 kMT 0.051 % + 15 kMT Function generator, multimeter w/shunt AC-RM Magnetic Flux (20 to 1000) Hz – Fluxmeters AC 1 MMT @ 20 Hz AC 500 kMT @ 40 Hz AC 200 kMT @ 80 Hz AC 100 kMT @ 160 Hz AC 100 kMT @ 320 Hz AC 100 kMT @ 1000 Hz 0.096 % + 3.2 kMT 0.11 % + 1.7 kMT 0.10 % + 0.74 kMT 0.11 % + 0.38 kMT 0.099 % + 0.2 kMT 0.11 % + 0.055 kMT Function generator, multimeter w/shunt III. Time & Frequency Parameter/Equipment Range CMC2, 3, 6 (±) Comments Frequency – Measure 30 Hz to 10 MHz 0.01 µHz/Hz Agilent 53210A/Locked to GPS Std ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, the value is defined as the percentage of reading, unless otherwise noted.
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 4 of 4 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8431 Castlewood Drive, Indianapolis, IN, 46250, US

39.76833, -86.15835

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.