What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1462.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 2 of 4
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Measure
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 750) V
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
0.078 % + 40 µV
0.076 % + 0.3 mV
0.075 % + 3 mV
0.075 % + 30 mV
0.081 % + 230 mV
Agilent 34401A
DMM
AC Current – Measure
(0 to 1) A
(0 to 3) A
10 Hz to 5 kHz
10 Hz to 5 kHz
0.14 % + 0.40 mA
0.24 % + 1.8 mA
Agilent 34401A
DMM
II. Magnetic Quantities
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Magnetic Flux
Density –
Hall Probe Meter w/
Probe
MI Probe Stations
Reference Magnets
(0 to 100) G
(200 to 500) G
(600 to 2000) G
(3000 to 10 000) G
(10 000 to 20 000) G
(20 000 to 30 000) G
(30 000 to 100 000) G
(430 to 1300) G
(900 to 2600) G
(1700 to 5200) G
(7000 to 21 000) G
(0 to 100) G
(100 to 500) G
(500 to 2000) G
(2000 to 10 000) G
0.38 % + 0.02 G
0.36 % + 0.1 G
0.35 % + 0.4 G
0.35 % + 2 G
0.35 % + 4 G
1.2 % + 10 G
1.2 % + 20 G
0.009 % + 0.12 G
0.044 % + 1.2 G
0.022 % + 1.2 G
0.055 % + 12 G
0.47 % + 0.05 G
0.37 % + 0.05 G
0.38 % + 0.06 G
0.37 % + 0.94 G
MI probe calibration
station
Metrolab PT 2025
NMR system
MI 2100 gaussmeter | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 3 of 4
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Magnetic Flux –
Fluxmeters
(0 to 100) kMT
(100 to 200) kMT
(200 to 500) kMT
(0.5 to 1) MMT
(1 to 2) MMT
(2 to 5) MMT
(5 to 10) MMT
(10 to 20) MMT
(20 to 50) MMT
(50 to 100) MMT
0.021 % + 0.075 kMT
0.035 % + 0.11 kMT
0.048 % + 0.1 kMT
0.049 % + 0.2 kMT
0.055 % + 0.16 kMT
0.048 % + 0.99 kMT
0.052 % + 1.3 kMT
0.054 % + 2.1 kMT
0.057 % + 2.5 kMT
0.051 % + 15 kMT
Function generator,
multimeter w/shunt
AC-RM Magnetic Flux
(20 to 1000) Hz –
Fluxmeters
AC 1 MMT @ 20 Hz
AC 500 kMT @ 40 Hz
AC 200 kMT @ 80 Hz
AC 100 kMT @ 160 Hz
AC 100 kMT @ 320 Hz
AC 100 kMT @ 1000 Hz
0.096 % + 3.2 kMT
0.11 % + 1.7 kMT
0.10 % + 0.74 kMT
0.11 % + 0.38 kMT
0.099 % + 0.2 kMT
0.11 % + 0.055 kMT
Function generator,
multimeter w/shunt
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
Frequency – Measure
30 Hz to 10 MHz
0.01 µHz/Hz
Agilent
53210A/Locked to
GPS Std
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, the value is defined as the percentage of reading, unless otherwise noted. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1462.01) Revised 02/25/2026 Page 4 of 4
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Quality Control Sales and ServicesIndianapolis, IN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Endress+HauserGreenwood, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Radian ResearchLafayette, IN · ~96 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsClayton, OH · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Midwest MetrologyClayton, OH · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.