Instrument Calibration Solutions
7550 B Jacks Lane, 45315, Clayton, OH, United States
Visit website- Scope lines
- 19
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 19 scope lines.
A2LA certificate 2332.02 · 19 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 2 of 18
Parameter/Equipment
Range CMC2, 4 (±) Comments
Pins, Plug Gages, & Master
Disk
Up to 20 in
2.3 µin/in + 12 µin
LMU1000A
Micrometers3
Up to 1 in
(1 to 4) in
(4 to 24) in
(24 to 40) in
4.0 µin/in + 10 µin
2.9 µin/in + 43 µin
2.9 µin/in + 77 µin
1.8 µin/in + 400 µin
Gage blocks
Calipers3
Up to 24 in
(24 to 40) in
0.7 µin/in + 430 µin
11 µin/in + 340 µin
Gage blocks
Indicators
Up to 2 in
46 µin
Gage blocks
Height Gages
Up to 48 in
7.3 µin/in + 50 µin
Gage blocks
End Rods
Up to 20 in
(20 to 40) in
2 µin/in + 16 µin
2 µin/in + 32 µin
LMU1000A
Optical Comparators3 –
X/Y Linear Accuracy
Angle
X/Y Perpendicularity
Magnification
Up to 12 in
30 in chart (in decimal
degree)
Up to 3 in
Up to 30 in chart
(76 + 2.8L) µin
0.022°
80 µin
0.003 in
Max Levy glass grid
Measuring Microscopes –
X-Y Axis
Up to 12 in
3 µin/in + 65 µin
6 x 12 glass grid | to 20 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 3 of 18
Parameter/Equipment
Range CMC2, 4 (±) Comments
Video Measuring
Systems3 –
X-Y Axis
Z Axis
Up to 12 in
Up to 18 in
Up to 24 in
Up to 4 in
3.7 µin/in + 34 µin
5.2 µin/in + 27 µin
5.1 µin/in + 34 µin
13 µin/in + 33 µin
6 x 12 glass grid
18 x 18 glass grid
18 x 24 glass grid
Gage blocks
Ring Gages
(0.125 to 0.25) in
(0.25 to 1) in
(1 to 3) in
(3 to 7) in
11 µin
5.4 µin/in + 9.8 µin
1.0 µin/in + 15 µin
1.3 µin/in + 15 µin
LMU1000A
Coating Thickness Gages
Up to 60 mils
0.13 % + 0.14 mils
Thickness standards
Surface Plates Grade AA,
A, & B
3 –
Flatness
Repeat Reading
Up to 192 in DL
Up to 0.002 in
4.6 µin + 0.8 µin/in
24 µin
LDDM laser
DL = diagonal
length
Repeat-o-meter
Surface Roughness Meters
& Profilometer
(119.0 to 121.0) µin
Ra
2.1 µin
Roughness specimen
Gage Blocks
(0.05 to 1) in
(1 to 4) in
(4 to 20) in
2.4 µin/in + 2.8 µin
2.4 µin/in + 1.7 µin
4 µin/in + 0.2 µin
LMU1000A, master
gage blocks
Thread Plugs
Pitch Diameter
Major Diameter
Up to 8 in
Up to 12 in
96 µin
2 µin/in + 56 µin
LMU1000A, master
gage blocks, thread
wires | to 12 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 4 of 18
III. Electrical DC/Low Frequency
Parameter/Equipment Range CMC2, 7 (±) Comments
DC Voltage3 – Generate
(0 to 329.9999) mV
(0 to 3.299 999) V
(0 to 32.999 99) V
(30 to 329.9999) V
(100 to 1020) V
20 nV/mV + 1000 nV
11 μV/V + 2 μV
12 μV/V + 20 μV
18 μV/V + 160 μV
18 μV/V + 1500 μV
5520A
DC Voltage3 – Measure
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(0 to 120) V
(0 to 1050) V
(0 to 10) kV
(10 to 35) kV
(35 to 70) kV
(70 to 90) kV
6.4 nV/mV + 530 nV
5.2 μV/V + 0.53 μV
5.2 μV/V + 1.4 μV
7.4 μV/V + 53 μV
23 μV/V + 330 μV
0.05 % + 0.006 V
0.07 % + 0.06 V
0.12 % + 0.06 V
0.28 % + 0.06 V
3458A
Vitrek 4700
Vitrek HVL-35
Vitrek HVL-70
Vitrek HVL-150
DC Current3 – Generate
Clamp-On Meter
(0 to 329.999) μA
(0 to 3.299 99) mA
(0 to 32.9999) mA
(0 to 329.999) mA
(0 to 1.099 99) A
(1.1 to 2.999 99) A
(0 to 10.9999) A
(11 to 20.5) A
(20 to 1000) A
0.015 % + 20 nA
0.01 % + 0.05 μA
0.01 % + 0.25 μA
0.01 % + 2.5 μA
0.02 % + 0.04 mA
0.039 % + 0.032 mA
0.051 % + 0.5 mA
0.095 % + 1.6 mA
0.3 % + 0.68 A
5520A
Fluke 55xx w/50
turn coil
DC Current3 – Measure
(0 to 120) nA
(0 to 1.2) μA
(0 to 12) μA
(0 to 120) μA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.05) A
0.033 pA/nA + 52 pA
0.024 nA/μA + 0.052 nA
0.026 nA/μA + 0.087 nA
0.027 nA/μA + 0.76 nA
0.025 μA/mA + 0.0053 μA
0.026 μA/mA + 0.053 μA
0.046 μA/mA + 0.54 μA
0.13 mA/A + 0.012 mA
3458A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 5 of 18
Parameter/Equipment
Range CMC2, 7 (±) Comments
Resistance3 –
Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
45 μΩ/Ω + 1000 μΩ
32 μΩ/Ω + 1400 μΩ
29 μΩ/Ω + 1400 μΩ
27 μΩ/Ω + 2100 μΩ
29 mΩ/kΩ + 1.6 mΩ
27 mΩ/kΩ + 21 mΩ
29 mΩ/kΩ + 16 mΩ
27 mΩ/kΩ + 210 mΩ
29 mΩ/kΩ + 160 mΩ
33 mΩ/kΩ + 2000 mΩ
32 Ω/MΩ + 2.3 Ω
60 Ω/MΩ + 30 Ω
130 Ω/MΩ + 43 Ω
250 Ω/MΩ + 2600 Ω
520 Ω/MΩ + 2900 Ω
3000 Ω/MΩ + 110 000 Ω
15 000 Ω/MΩ + 570 000 Ω
Fluke 5520
Resistance3 –
Generate, Fixed
Points
1.0 mΩ
10.0 mΩ
100.0 mΩ
1.0 Ω
10.0 Ω
100.0 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
0.000 25 mΩ
0.0025 mΩ
0.025 mΩ
0.000 25 Ω
0.0025 Ω
0.025 Ω
24 mΩ
240 mΩ
2.4 Ω
30 Ω
330 Ω
24 kΩ
7.1 MΩ
56 MΩ
1.1 GΩ
Fixed standard
resistors | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 6 of 18
Parameter/Equipment
Range CMC2, 7 (±) Comments
Resistance3 –
Measure
(0 to 12) Ω
(0 to 120) Ω
(0 to 1.2) kΩ
(0 to 12) kΩ
(0 to 120) kΩ
(0 to 1.2) MΩ
(0 to 12) MΩ
(0 to 120) MΩ
(0 to 1.2) GΩ
18 μΩ/Ω + 70 μΩ
15 μΩ/Ω + 700 μΩ
12 mΩ/kΩ + 2.4 mΩ
12 mΩ/kΩ + 24 mΩ
12 mΩ/kΩ + 240 mΩ
18 Ω/MΩ + 3.3 Ω
61 Ω/MΩ + 120 Ω
610 Ω/MΩ + 2100 Ω
5700 kΩ/GΩ + 110 kΩ
Agilent 3458A
Electrical Simulation
of RTDs3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.08 °C
0.08 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.24 °C
0.08 °C
0.08 °C
0.1 °C
0.11 °C
0.12 °C
0.14 °C
0.26 °C
0.07 °C
0.08 °C
0.09 °C
0.1 °C
0.1 °C
0.11 °C
0.12 °C
0.24 °C
Fluke 5522A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 7 of 18
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
RTDs3 – (cont)
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.07 °C
0.07 °C
0.07 °C
0.08 °C
0.17 °C
0.16 °C
0.16 °C
0.19 °C
0.07 °C
0.08 °C
0.08 °C
0.09 °C
0.1 °C
0.1 °C
0.11 °C
0.13 °C
0.07 °C
0.07 °C
0.07 °C
0.08 °C
0.09 °C
0.09 °C
0.09 °C
0.24 °C
0.1 °C
0.1 °C
0.15 °C
0.32 °C
Fluke 5522A
Electrical Simulation of
Thermocouples3 –
Type B
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
0.45 °C
0.34 °C
0.30 °C
0.34 °C
Fluke 5522A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 8 of 18
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Simulation of
Thermocouples3 – (cont)
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.31 °C
0.26 °C
0.31 °C
0.50 °C
0.84 °C
0.51 °C
0.19 °C
0.17 °C
0.18 °C
0.23 °C
0.28 °C
0.19 °C
0.16 °C
0.18 °C
0.24 °C
0.35 °C
0.21 °C
0.19 °C
0.29 °C
0.41 °C
0.40 °C
0.22 °C
0.19 °C
0.18 °C
0.27 °C
0.59 °C
0.37 °C
0.35 °C
0.48 °C
0.49 °C
0.38 °C
0.39 °C
0.48 °C
0.64 °C
0.26 °C
0.19 °C
0.17 °C
Fluke 5522A | to 2316 °C |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 9 of 18
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Generate
(1.0 to 32.999) mV
(33 to 329.999) mV
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.079 % + 6 μV
0.015 % + 6 μV
0.021 % + 6.1 μV
0.1 % + 6.1 μV
0.36 % + 12 μV
0.79 % + 50 μV
0.031 % + 7.8 μV
0.014 % + 8.2 μV
0.016 % + 8.8 μV
0.034 % + 8.9 μV
0.081 % + 32 μV
0.2 % + 74 μV
0.029 % + 0.056 mV
0.015 % + 0.06 mV
0.019 % + 0.068 mV
0.029 % + 0.056 mV
0.069 % + 0.13 mV
0.24 % + 0.6 mV
0.031 % + 0.67 mV
0.015 % + 0.6 mV
0.024 % + 0.6 mV
0.034 % + 0.67 mV
0.089 % + 1.7 mV
0.019 % + 2.2 mV
0.02 % + 6.4 mV
0.025 % + 5.7 mV
0.032 % + 5.6 mV
0.2 % + 54 mV
0.03 % + 9.6 mV
0.026 % + 9.8 mV
0.03 % + 9.6 mV
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 10 of 18
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(1.2 to 12) mV
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 100) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.036 % + 3.5 µV
0.024 % + 1.3 µV
0.036 % + 1.3 µV
0.12 % + 1.2 µV
0.58 % + 1.3 µV
4.6 % + 2.2 μV
0.0096 % + 4.4 μV
0.009 % + 2.2 μV
0.017 % + 2.2 μV
0.041 % + 2.1 μV
0.098 % + 2.2 μV
0.35 % + 12 μV
1.2 % + 11 μV
1.7 % + 11 μV
0.0096 % + 0.044 mV
0.009 % + 0.022 mV
0.065 % + 0.0089 mV
0.037 % + 0.022 mV
0.098 % + 0.022 mV
0.35 % + 0.12 mV
1.2 % + 0.11 mV
1.7 % + 0.11 mV
0.0096 % + 0.44 mV
0.009 % + 0.22 mV
0.017 % + 0.22 mV
0.036 % + 0.22 mV
0.089 % + 0.33 mV
0.35 % + 1.1 mV
1.2 % + 1.1 mV
1.7 % + 1.1 mV
0.024 % + 4.6 mV
0.023 % + 2.3 mV
0.024 % + 2.3 mV
0.041 % + 2.2 mV
0.14 % + 2.2 mV
0.47 % + 11 mV
1.7 % + 11 mV
Agilent 3458A | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 11 of 18
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(cont)
(70 to 700) V
Up to 10 kV
(10 to 30) kV
(30 to 50) kV
(50 to 70) kV
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(30 to 200) Hz
(30 to 200) Hz
(30 to 100) Hz
< 65 Hz
0.048 % + 46 mV
0.047 % + 23 mV
0.07 % + 23 mV
0.14 % + 23 mV
0.35 % + 22 mV
0.16 % + 0.006 V
0.14 % + 0.06 V
0.16 % + 0.06 V
0.69 % + 0.06 V
Agilent 3458A
Vitrek 4700
Vitrek HVL-35
Vitrek HVL-70
Vitrek HVL-150
AC Current3 – Generate
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.16 % + 75 nA
0.12 % + 76 nA
0.096 % + 82 nA
0.24 % + 110 nA
0.62 % + 160 nA
1.2 % + 310 nA
0.15 % + 0.12 μA
0.096 % + 0.12 μA
0.078 % + 0.13 μA
0.16 % + 0.17 μA
0.39 % + 0.22 μA
0.77 % + 0.44 μA
0.14 % + 1.6 μA
0.071 % + 1.6 μA
0.031 % + 1.7 μA
0.062 % + 1.7 μA
0.16 % + 2.3 μA
0.33 % + 2.2 μA
0.14 % + 16 μA
0.071 % + 16 μA
0.031 % + 17 μA
0.079 % + 39 μA
0.15 % + 79 μA
0.32 % + 160 μA
Fluke 5522A | 70 to 700 V |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 12 of 18
Parameter/Range
Frequency CMC2, 7, 8 (±) Comments
AC Current3 – Generate
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
Clamp Meters:
(20 to 1000) A
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(45 to 65) Hz
0.14 % + 0.086 mA
0.039 % + 0.081 mA
0.47 % + 0.76 mA
1.9 % + 3.6 mA
0.14 % + 0.037 mA
0.047 % + 0.079 mA
0.48 % + 0.63 mA
1.9 % + 3.6 mA
0.048 % + 1.6 mA
0.076 % + 1.6 mA
2.4 % + 1.5 mA
0.095 % + 3.6 mA
0.12 % + 4.3 mA
2.3 % + 5.3 mA
0.34 % of IV + 0.72 A
Fluke 5522A
Fluke 5500/coil
AC Current3 – Measure
(6 to 120) μA
(0.06 to 1.2) mA
(0.6 to 12) mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.47 % + 35 nA
0.18 % + 35 nA
0.071 % + 35 nA
0.071 % + 35 nA
0.47 % + 0.24 μA
0.18 % + 0.23 μA
0.072 % + 0.24 μA
0.035 % + 0.24 μA
0.072 % + 0.24 μA
0.48 % + 0.46 μA
0.66 % + 1.7 μA
0.47 % + 2.4 μA
0.18 % + 2.3 μA
0.072 % + 2.4 μA
0.035 % + 2.4 μA
0.072 % + 2.4 μA
0.48 % + 4.6 μA
0.66 % + 17 μA
Agilent 3458A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 13 of 18
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Current3 – Measure
(cont)
(6 to 120) mA
(0.0525 to 1.05) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
0.47 % + 24 μA
0.18 % + 23 μA
0.072 % + 24 μA
0.035 % + 24 μA
0.072 % + 24 μA
0.48 % + 46 μA
0.66 % + 170 μA
0.47 % + 0.23 mA
0.19 % + 0.23 mA
0.092 % + 0.23 mA
0.12 % + 0.24 mA
0.35 % + 0.24 mA
1.2 % + 0.47 mA
Agilent 3458A
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(10 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.1 nF
0.25 % + 0.1 nF
0.25 % + 0.3 nF
0.25 % + 1.0 nF
0.25 % + 3.0 nF
0.25 % + 10 nF
0.4 % + 30 nF
0.45 % + 100 nF
0.45 % + 300 nF
0.45 % + 1.0 μF
0.45 % + 3.0 μF
0.45 % + 10 μF
0.75 % + 30 μF
1.1 % + 100 μF
Fluke 5522A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 14 of 18
Parameter/Equipment
Range CMC2, 4 (±) Comments
Oscilloscope3 –
Amplitude –
50 Ω Load
1 MΩ Load
Leveled Sine Wave
Amplitude –
5 mV to 5.5 V
5 mV to 3.5 V
Flatness –
Relative to 50 kHz
5 mV to 5.5 V
5 mV to 3.5 V
Time Marker –
50 Ω Load
Edge – Rise Time
50 Ω Load
(-6.6 to 6.6) V
(-130 to 130) V
50 kHz Reference:
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 1 ns
1 kHz to 2 MHz
(200 to 300) ps
2 MHz to 10 MHz
(200 to 350) ps
0.25 % + 40 μV
0.05 % + 40 μV
2.0 % + 300 µV
3.5 % + 300 µV
4.0 % + 300 µV
6.0 % + 300 µV
1.5 % + 100 µV
2.0 % + 100 µV
4.0 % + 100 µV
5.0 % + 100 µV
(25 + 1000t) µs/s
2.5 µs/s
100 ps
100 ps
Fluke 55xx/SC
t is the time in
seconds
At cardinal point
sequence 5-2-1 | ||
| 15 | ASTM Class 6 & 7 | - | See scope document |
| 16 | ASTM Class 6 | Rockwell Hardness Testers | - |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 17 of 18
Parameter/Equipment
Range
CMC2, 4 (±) Comments
Indirect Verification of
Rockwell Hardness &
Rockwell Superficial
Hardness Testers (cont)
HR15TW:
(60 to 80) HR15TW
(80 to 86) HR15TW
(86 to 93) HR15TW
HR30TW:
(15 to 56) HR30TW
(56 to 69) HR30TW
(69 to 83) HR30TW
0.29 HR15TW
0.58 HR15TW
0.53 HR15TW
0.48 HR30TW
0.41 HR30TW
0.45 HR30TW
Rockwell hardness test
blocks
V. Thermodynamics
Parameter/Equipment Range CMC2, 4, 6 (±) Comments
Temperature3 – Measure
Water Baths, Thermal
Wells, Refrigerators,
Chambers
(-196 to 0) °C
(0 to 660) °C
0.021 °C
0.007 % + 0.021 °C
Fluke 1502A + 5609
PRT
Temperature3 –
Measuring Equipment
Digital & Analogue
Thermometers
(-5 to 125) °C
(50 to 660) °C
0.021 °C
0.007 % + 0.021 °C
Fluke 1502A + 5609
PRT, Accumac PRT,
thermal baths.
Relative Humidity –
Measuring Equipment
(10 to 80) % RH
1.1 % RH
Rotronic sensor
Infrared Temperature –
Measuring Equipment
(35 to 500) °C
0.42 % of rdg + 0.33 °C
Fluke 4181
Ɛ = 0.9 to 1.0
λ = (8 to 14) µm | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.02) Revised 1/20/2026 Page 18 of 18
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±) Comments
Frequency3 – Measure
DC to 3 GHz
0.21 µHz/Hz
Agilent 53132A
opt.10
Frequency3 – Measuring
Equipment
DC to 600 MHz
0.21 µHz/Hz
Fluke 5520A/SC600
Stopwatches / Timers3
(0 to 19.99) s/day
0.037 s/day
Timometer
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and percentages are percentage of reading, unless otherwise indicated.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
8 In the statement of CMC, IV represents “Indicated Value”.
9 In the statement of the CMC, contributions from “the best existing device” are not included. | ||
| 19 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- MSI-Viking Gage, LLC.Greer, SC · ~579 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Rockwell Hardness Testers
- MSI-Viking GageCanton, MI · ~953 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Rockwell Hardness Testers
- Midwest MetrologyClayton, OH · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994