Instrument Calibration Solutions
413 Hopewell Avenue, 15001, Aliquippa, PA, United States
Visit website- Scope lines
- 21
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 21 scope lines.
A2LA certificate 2332.01 · 21 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 2 of 20
II. Dimensional
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Angle – Measure
Up to 90°
10 arc sec
Vision system
Angle – Measuring
Equipment6
(Protractor, Inclinometer,
Levels)
Up to 90°
1.8 arc sec
Master angle blocks,
master 90˚ square
Bore Gages
Up to 4 in
(52 + 26L)
Ring gages, surface
plate
Calipers3, 6
Up to 24 in
(24 to 40) in
5 µin/in + 4.6 µin
4.7 µin/in + 4.5 µin
Gage blocks
Coating Thickness Gages
Up to 60 mils
0.13 % + 0.14 mils
Thickness standards
End Rods
Up to 40 in
2.3 µin/in + 14 µin
LMU1000A
Gage Blocks
(0.05 to 1) in
(1 to 4) in
(4 to 20) in
2.2 µin/in + 2.4 µin
1.4 µin/in + 1.7 µin
1.9 µin/in + 0.6 µin
Lab master,
LMU1000A,
master gage blocks
Height Gage
Up to 48 in
(50 + 4.1L) µin
Gage blocks, surface
plate
Indicators
Up to 2 in
16 µin
Lab master,
LMU1000A,
master gage blocks
Measuring Microscopes –
X-Y Axis
Up to 12 in
3 µin/in + 65 µin
6 x 12 glass grid | to 90 ° |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 3 of 20
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Micrometer3
Up to 1 in
(1 to 4) in
(4 to 24) in
(24 to 40) in
4.0 µin/in + 10 µin
2.9 µin/in + 43 µin
2.9 µin/in + 77 µin
1.7 µin/in + 400 µin
Gage blocks
Optical Comparators3 –
Linear Accuracy
Angle
X/Y Perpendicularity
Magnification
Up to 12 in
30 in chart (in
decimal degree)
Up to 3 in
Up to 30 in chart
2.8 µin/in + 76 µin
0.022°
80 µin
0.003 in
Max Levy glass grid
Pins, Plug Gages, &
Master Disk
Up to 20 in
1.5 µin/in + 9.3 µin
Lab master,
LMU1000A,
master gage blocks
Radius Gages
Up to 8 in
360 µin
Vision system
Ring Gages
(0.125 to 0.25) in
(0.25 to 1) in
(1 to 3) in
(3 to 15) in
11 µin
5.3 µin/in + 9.8 µin
1.0 µin/in + 14 µin
1.6 µin/in + 14 µin
LMU1000A, master
ring
Surface Plates Grade AA,
A, & B3 –
Flatness
Repeat Reading
Up to 192 in DL
Up to 0.002 in
5.3 µin + 0.51 µin/in
29 µin
LDDM laser
DL = diagonal length
Repeat-o-meter
Surface Roughness Meters
& Profilometer
(119.0 to 121.0) µin
Ra
2.1 µin
Roughness specimen
Tape Measure
Up to 100 ft
0.004 % + 0.0014 in
LDDM laser, length
calibration system | to 192 in |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 4 of 20
Parameter/Equipment Range CMC2 (±) Comments
Thread Plugs –
Simple Pitch Diameter
Major Diameter
Up to 8 in
Up to 12 in
96 µin
2 µin/in + 56 µin
LMU1000A, master
gage blocks & thread
wires
Video Measuring
Systems
3 –
X-Y Axis
Z Axis
TurnCheck
Height (Z Axis)
Width (X-Y Axis)
Up to 12 in
Up to 18 in
Up to 24 in
Up to 4 in
Up to 600 mm
Up to 130 mm
3.7 µin/in + 34 µin
3.3 µin/in + 29 µin
3.2 µin/in + 35 µin
11 µin/in + 34 µin
0.71 µm
0.44 µm
6 x 12 glass grid
12 x 12 glass grid
18 x 24 glass grid
Gage blocks
Turncheck height gage
Turncheck width gage
III. Dimensional Testing/Calibration1
Parameter/Equipment Range CMC2 (±) Comments
Length – 1 Dimensional9 –
Measure
Up to 240 in
1.3 µin/in + 1.5 µin
LDDM laser
Length – 2 Dimensional9 –
Measure
Up to 24 in DL
6.7 µin/in + 89 µin
Vision system
DL = diagonal length | to 8 in |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 5 of 20
IV. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 4 (±) Comments
DC Voltage3, 6 – Generate
(0 to 329.9999) mV
(0 to 3.299 999) V
(0 to 32.999 99) V
(30 to 329.9999) V
(100 to 1020) V
20 nV/mV + 1000 nV
11 µV/V + 2 µV
12 µV/V + 20 µV
18 µV/V + 160 µV
18 µV/V + 1500 µV
Fluke 5520A
DC Voltage3 – Measure
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(0 to 120) V
(0 to 1050) V
(0 to 10) kV
(10 to 35) kV
(35 to 70) kV
(70 to 90) kV
6.4 nV/mV + 530 nV
5.2 µV/V + 0.53 µV
5.2 µV/V + 1.4 µV
7.4 µV/V + 53 µV
23 µV/V + 330 µV
0.05 % + 0.006 V
0.07 % + 0.06 V
0.12 % + 0.06 V
0.28 % + 0.1 V
Agilent 3458A
opt 2
Vitrek 4700
Vitrek HVL-35
Vitrek HVL-70
Vitrek HVL-150
DC Current3, 6 – Generate
Clamp-On Meters
(0 to 329.999) µA
(0 to 3.299 99) mA
(0 to 32.9999) mA
(0 to 329.999) mA
(0 to 1.099 99) A
(1.1 to 2.999 99) A
(0 to 10.9999) A
(11 to 20.5) A
(20 to 1000) A
0.015 % + 20 nA
0.01 % + 0.05 µA
0.01 % + 0.25 µA
0.01 % + 2.5 µA
0.02 % + 0.04 mA
0.039 % + 0.032 mA
0.051 % + 0.5 mA
0.095 % + 1.6 mA
0.29 % + 0.082 A
Fluke 5520A
Fluke 5520A w/
50 turn coil
DC Current3, 6 – Measure
(0 to 120) nA
(0 to 1.2) µA
(0 to 12) µA
(0 to 120) µA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.05) A
0.033 pA/nA + 52 pA
0.024 nA/µA + 0.052 nA
0.026 nA/µA + 0.087 nA
0.027 nA/µA + 0.76 nA
0.025 µA/mA + 0.0053 µA
0.026 µA/mA + 0.053 µA
0.046 µA/mA + 0.54 µA
0.13 mA/A + 0.012 mA
Agilent 3458A
opt 2 | to 1020 V |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 6 of 20
Parameter/Equipment
Range CMC2, 4 (±) Comments
Resistance3, 6 –
Generate
Fixed Points
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
1.0 mΩ
10.0 mΩ
100.0 mΩ
1.0 Ω
10.0 Ω
100.0 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
45 µΩ/Ω + 1000 µΩ
32 µΩ/Ω + 1400 µΩ
29 µΩ/Ω + 1400 µΩ
27 µΩ/Ω + 2100 µΩ
29 mΩ/kΩ + 1.6 mΩ
27 mΩ/kΩ + 21 mΩ
29 mΩ/kΩ + 16 mΩ
27 mΩ/kΩ + 210 mΩ
29 mΩ/kΩ + 160 mΩ
33 mΩ/kΩ + 2000 mΩ
32 Ω/MΩ + 2.3 Ω
60 Ω/MΩ + 30 Ω
130 Ω/MΩ + 43 Ω
250 Ω/MΩ + 2600 Ω
520 Ω/MΩ + 2900 Ω
3000 Ω/MΩ + 110 000 Ω
15 000 Ω/MΩ + 570 000 Ω
0.000 25 mΩ
0.0025 mΩ
0.025 mΩ
0.000 25 Ω
0.0025 Ω
0.025 Ω
24 mΩ
240 Ω
2.5 Ω
30 Ω
10 kΩ
920 kΩ
9.2 MΩ
140 MΩ
3.9 GΩ
Fluke 5520A
Fixed standard
resistors
Resistance3, 6 –
Measure
(0 to 12) Ω
(0 to 120) Ω
(0 to 1.2) kΩ
(0 to 12) kΩ
(0 to 120) kΩ
(0 to 1.2) MΩ
(0 to 12) MΩ
(0 to 120) MΩ
(0 to 1.2) GΩ
18 µΩ/Ω + 70 µΩ
15 µΩ/Ω + 700 µΩ
12 mΩ/kΩ + 2.4 mΩ
12 mΩ/kΩ + 24 mΩ
12 mΩ/kΩ + 240 mΩ
18 Ω/MΩ + 3.3 Ω
61 Ω/MΩ + 120 Ω
610 Ω/MΩ + 2100 Ω
5700 kΩ/GΩ + 110 kΩ
Agilent 3458A
opt 2 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 7 of 20
Parameter/Equipment Range CMC2 (±) Comments
Electrical Simulation of
RTDs3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.08 °C
0.08 °C
0.09 °C
0.11 °C
0.12 °C
0.14 °C
0.24 °C
0.08 °C
0.08 °C
0.1 °C
0.11 °C
0.12 °C
0.14 °C
0.26 °C
0.07 °C
0.08 °C
0.09 °C
0.1 °C
0.1 °C
0.11 °C
0.12 °C
0.24 °C
0.07 °C
0.07 °C
0.07 °C
0.08 °C
0.17 °C
0.16 °C
0.16 °C
0.19 °C
0.07 °C
0.08 °C
0.08 °C
0.09 °C
0.1 °C
0.1 °C
0.11 °C
0.13 °C
Fluke 5520A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 8 of 20
Parameter/Equipment Range CMC2 (±) Comments
Electrical Simulation of RTDs3
– (cont)
Pt 385, 1000 Ω
Ni 120, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.07 °C
0.07 °C
0.07 °C
0.08 °C
0.09 °C
0.09 °C
0.09 °C
0.24 °C
0.1 °C
0.1 °C
0.15 °C
0.32 °C
Fluke 5520A
Electrical Simulation of
Thermocouples3 –
Type B
Type C
Type E
(250 to 349) °C
(350 to 444) °C
(445 to 579) °C
(580 to 749) °C
(750 to 999) °C
(1000 to 1820) °C
(0 to 249) °C
(250 to 999) °C
(1000 to 1499) °C
(1500 to 1799) °C
(1800 to 1999) °C
(2000 to 2249) °C
(2250 to 2315) °C
(-270 to -244) °C
(-245 to -194) °C
(-195 to -154) °C
(-155 to -90) °C
(-90 to 14) °C
(15 to 889) °C
(890 to 1000) °C
0.95 °C
0.74 °C
0.58 °C
0.45 °C
0.37 °C
0.29 °C
0.20 °C
0.16 °C
0.18 °C
0.21 °C
0.23 °C
0.29 °C
0.32 °C
1.20 °C
0.18 °C
0.10 °C
0.08 °C
0.07 °C
0.06 °C
0.07 °C
Ectron 1140A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 9 of 20
Parameter/Equipment Range CMC2 (±) Comments
Electrical Simulation of
Thermocouples3 – (cont)
Type J
Type K
Type N
Type R
Type S
Type T
(-210 to -179) °C
(-180 to -119) °C
(-120 to -49) °C
(-50 to 989) °C
(990 to 1200) °C
(-270 to -254) °C
(-255 to -194) °C
(-195 to -114) °C
(-115 to -54) °C
(-55 to 999) °C
(1000 to 1372) °C
(-270 to -259) °C
(-260 to -199) °C
(-200 to -139) °C
(-140 to -69) °C
(-70 to 24) °C
(25 to 159) °C
(160 to 1300) °C
(-50 to -29) °C
(-30 to 44) °C
(45 to 159) °C
(160 to 379) °C
(380 to 774) °C
(775 to 1768) °C
(-50 to -29) °C
(-30 to 44) °C
(45 to 159) °C
(160 to 379) °C
(380 to 774) °C
(775 to 1768) °C
(-270 to -254) °C
(-255 to -239) °C
(-240 to -209) °C
(-210 to -149) °C
(-150 to -39) °C
(-40 to 99) °C
(100 to 400) °C
0.12 °C
0.10 °C
0.08 °C
0.07 °C
0.07 °C
2.20 °C
0.70 °C
0.12 °C
0.09 °C
0.07 °C
0.08 °C
5.0 °C
1.0 °C
0.23 °C
0.15 °C
0.12 °C
0.10 °C
0.09 °C
0.65 °C
0.55 °C
0.40 °C
0.30 °C
0.26 °C
0.22 °C
0.62 °C
0.56 °C
0.40 °C
0.33 °C
0.29 °C
0.26 °C
1.8 °C
0.49 °C
0.30 °C
0.18 °C
0.12 °C
0.08 °C
0.07 °C
Ectron 1140A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 10 of 20
Parameter/Range Frequency CMC2, 4 (±) Comments
AC Voltage3, 6 – Generate
(1 to 32.999) mV
(33 to 329.999) mV
(330 mV to 3.3) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.079 % + 6 µV
0.015 % + 6 µV
0.021 % + 6.1 µV
0.1 % + 6.1 µV
0.36 % + 12 µV
0.79 % + 50 µV
0.031 % + 7.8 µV
0.014 % + 8.2 µV
0.016 % + 8.8 µV
0.034 % + 8.9 µV
0.081 % + 32 µV
0.2 % + 74 µV
0.029 % + 0.0o mV
0.015 % + 0.06 mV
0.019 % + 0.068 mV
0.029 % + 0.056 mV
0.069 % + 0.13 mV
0.24 % + 0.6 mV
0.031 % + 0.67 mV
0.015 % + 0.6 mV
0.024 % + 0.6 mV
0.034 % + 0.67 mV
0.089 % + 1.7 mV
0.019 % + 2.2 mV
0.02 % + 6.4 mV
0.025 % + 5.7 mV
0.032 % + 5.6 mV
0.2 % + 54 mV
0.03 % + 9.6 mV
0.026 % + 9.8 mV
0.03 % + 9.6 mV
Fluke 5520A
AC Voltage3,6 – Measure
(1.2 to 12) mV
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.034 % + 3.5 µV
0.023 % + 1.2 µV
0.034 % + 1.3 µV
0.11 % + 1.3 µV
0.58 % + 1.2 µV
4.6 % + 2.2 µV
Agilent 3458A
opt 2 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 11 of 20
Parameter/Range
Frequency CMC2, 4 (±) Comments
AC Voltage3, 6 – Measure (cont)
(12 to 120) mV
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(70 to 700) V
Up to 10 kV
(10 to 30) kV
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 100) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(30 to 200) Hz
(30 to 200) Hz
0.0096 % + 4.4 µV
0.009 % + 2.2 µV
0.017 % + 2.2 µV
0.041 % + 2.1 µV
0.098 % + 2.2 µV
0.35 % + 12 µV
1.2 % + 11 µV
1.7 % + 11 µV
0.0096 % + 0.044 mV
0.009 % + 0.022 mV
0.065 % + 0.0089 mV
0.037 % + 0.022 mV
0.098 % + 0.022 mV
0.35 % + 0.12 mV
1.2 % + 0.11 mV
1.7 % + 0.11 mV
0.0096 % + 0.44 mV
0.009 % + 0.22 mV
0.017 % + 0.22 mV
0.036 % + 0.22 mV
0.089 % + 0.33 mV
0.35 % + 1.1 mV
1.2 % + 1.1 mV
1.7 % + 1.1 mV
0.024 % + 4.6 mV
0.023 % + 2.3 mV
0.024 % + 2.3 mV
0.041 % + 2.2 mV
0.14 % + 2.2 mV
0.47 % + 11 mV
1.7 % + 11 mV
0.048 % + 46 mV
0.047 % + 23 mV
0.07 % + 23 mV
0.14 % + 23 mV
0.35 % + 22 mV
0.16 % + 0.006 V
0.14 % + 0.06 V
Agilent 3458A
opt 2
Vitrek 4700
Vitrek HVL-35 | ||
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 12 of 20
Parameter/Range
Frequency CMC2, 4 (±) Comments
AC Voltage3,6 – Measure (cont)
(30 to 50) kV
(50 to 70) kV
(30 to 100) Hz
< 65 Hz
0.16 % + 0.06 V
0.69 % + 0.06 V
Vitrek HVL-70
Vitrek HVL-150
AC Current3,6 – Generate
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
0.16 % + 75 nA
0.12 % + 76 nA
0.096 % + 82 nA
0.24 % + 110 nA
0.62 % + 160 nA
1.2 % + 310 nA
0.15 % + 0.12 µA
0.096 % + 0.12 µA
0.078 % + 0.13 µA
0.16 % + 0.17 µA
0.39 % + 0.22 µA
0.77 % + 0.44 µA
0.14 % + 1.6 µA
0.071 % + 1.6 µA
0.031 % + 1.7 µA
0.062 % + 1.7 µA
0.16 % + 2.3 µA
0.33 % + 2.2 µA
0.14 % + 16 µA
0.071 % + 16 µA
0.031 % + 17 µA
0.079 % + 39 µA
0.15 % + 79 µA
0.32 % + 160 µA
0.14 % + 0.086 mA
0.039 % + 0.081 mA
0.47 % + 0.76 mA
1.9 % + 3.6 mA
0.14 % + 0.037 mA
0.047 % + 0.079 mA
0.48 % + 0.63 mA
1.9 % + 3.6 mA
0.048 % + 1.6 mA
0.076 % + 1.6 mA
2.4 % + 1.5 mA
Fluke 5520A | 30 to 50 kV |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 13 of 20
Parameter/Range
Frequency CMC2, 4 (±) Comments
AC Current3 – Generate
(cont)
(11 to 20.5) A
Clamp Meters:
(20 to 1000) A
(10 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(45 to 65) Hz
0.095 % + 3.6 mA
0.12 % + 4.3 mA
2.3 % + 5.3 mA
0.4 % + 0.078 A
Fluke 5520A & 50
turn coil
AC Current3,6 – Measure
(6 to 120) µA
(0.06 to 1.2) mA
(0.6 to 12) mA
(6 to 120) mA
(0.0525 to 1.05) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
0.46 % + 35 nA
0.17 % + 35 nA
0.071 % + 35 nA
0.071 % + 35 nA
0.47 % + 0.23 µA
0.17 % + 0.24 µA
0.073 % + 0.23 µA
0.036 % + 0.23 µA
0.073 % + 0.23 µA
0.47 % + 0.46 µA
0.65 % + 1.7 µA
0.47 % + 2.3 µA
0.17 % + 2.4 µA
0.073 % + 2.3 µA
0.036 % + 2.3 µA
0.073 % + 2.3 µA
0.47 % + 4.6 µA
0.65 % + 17 µA
0.47 % + 23 µA
0.17 % + 24 µA
0.073 % + 23 µA
0.036 % + 23 µA
0.073 % + 23 µA
0.47 % + 46 µA
0.65 % + 170 µA
0.46 % + 0.24 mA
0.19 % + 0.23 mA
0.092 % + 0.23 mA
0.11 % + 0.23 mA
0.35 % + 0.24 mA
1.2 % + 0.47 mA
Agilent 3458A
opt 2 | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 14 of 20
Parameter/Range Frequency CMC2, 4 (±) Comments
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.0999) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(10 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.5 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.1 nF
0.25 % + 0.1 nF
0.25 % + 0.3 nF
0.25 % + 1.0 nF
0.25 % + 3.0 nF
0.25 % + 10 nF
0.4 % + 30 nF
0.45 % + 100 nF
0.45 % + 300 nF
0.45 % + 1.0 µF
0.45 % + 3.0 µF
0.45 % + 10 µF
0.75 % + 30 µF
1.1 % + 100 µF
Fluke 5520A
Parameter/Equipment
Range CMC2 (±) Comments
Oscilloscope3 –
Amplitude –
50 Ω Load
1 MΩ Load
Leveled Sine Wave
Amplitude –
5 mV to 5.5 V
4 mV to 3.5 V
Flatness –
Relative to 50 kHz
5 mV to 5.5 V
4 mV to 3.5 V
(-6.6 to 6.6) V
(-130 to 130) V
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
0.25 % of output + 40 µV
0.05 % of output + 40 µV
2.0 % of output + 300 µV
3.5 % of output + 300 µV
4.0 % of output + 300 µV
6.0 % of output + 300 µV
6.0 % of output + 300 µV
1.5 % of output + 100 µV
2.0 % of output + 100 µV
4.0 % of output + 100 µV
5.0 % of output + 100 µV
Fluke
5522A/SC1100 | ||
| 15 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 15 of 20
Parameter/Equipment
Range CMC2 (±) Comments
Oscilloscope3 – (cont)
Time Marker6 –
50 Ω Load
Edge6 – Rise Time
50 Ω Load
5 s to 50 ms
20 ms to 1 ns
1 kHz to 2 MHz
(200 to 300) ps
(2 to 10) MHz
(200 to 350) ps
(25 + 1000t) µs/s
2.5 µs/s
100 ps
100 ps
Fluke 5520A/SC600
t = time in seconds
V. Electrical – RF Microwave
Parameter/Equipment Range CMC2, 5, 7 (±) Comments
Amplitude Flatness3 –
Measure (Relative to
100 kHz)
(-3 to 0) dBm
100 kHz to 80 MHz
0.042 dB
R&S NRP-Z51 power
sensor
Absolute Power3 –
Measure
(-13 to 20) dBm
100 kHz to 80 MHz
0.042 dB
R&S NRP-Z51 power
sensor
VI. Mechanical
Parameter/Equipment Range CMC2, 5 (±) Comments
Balance & Scales
Up to 30 kg
Up to 1000 lb
0.0002 % + 0.026 mg
0.016 % + 0.000 05 lb
Class F weight | -3 to 0 dBm |
| 16 | ASTM Class 6 & 7 | - | to 50000 lbf |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 17 of 20
Parameter/Equipment
Range CMC2, 5, 7 (±) Comments
Indirect Verification
of Rockwell Hardness
& Rockwell
Superficial Hardness
Testers (cont)
HR15TW:
(60 to 80) HR15TW
(80 to 86) HR15TW
(86 to 93) HR15TW
HR30TW:
(15 to 56) HR30TW
(56 to 69) HR30TW
(69 to 83) HR30TW
0.29 HR15TW
0.58 HR15TW
0.53 HR15TW
0.48 HR30TW
0.41 HR30TW
0.45 HR30TW
Rockwell hardness test
blocks
Pressure3 – Measuring
Equipment
Pneumatic, Absolute
Pneumatic
Vacuum
Water
(0.13 to 14.7) psia
(14.7 to 15.7) psia
(15.7 to 21.1) psia
(21.1 to 22.7) psia
(22.7 to 30.7) psia
(4 to 860) inH
2O
(0 to 1) psi
(1 to 6.4) psi
(3 to 500) psi
(501 to 1500) psi
(1501 to 5000) psi
(0 to 2) inH
2O
(0 to -15) psi
(0 to -1) psi
(10 to 10 000) psi
0.0025 psia
0.0018 psia
0.0019 psia
0.0020 psia
0.0026 psia
0.02 %
0.000 12 psi
0.0008 psi
0.01 % + 0.000 06 psi
0.012 % + 0.003 psi
0.012 % + 0.001 psi
0.000 48 inH
2O
0.002 psi
0.0001 psi
0.01 % + 0.0006 psi
Mensor CPC6000
transducers
PKII 654WC-SS
Mensor CPC6050
transducers
T3500 deadweight
Mensor CPC8000
transducer
Dwyer 1430 microtector
Mensor CPC6000
transducer
Fluke P3224
Torque3 – Measuring
Equipment
(4 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(20 to 250) lbf·ft
(60 to 600) lbf·ft
0.25 % + 0.023 lbf·in
0.25 % + 0.24 lbf·in
0.27 % + 0.27 lbf·in
0.27 % + 0.067 lbf·ft
0.6 %
Snap-On TTC400 system
Snap-On TTC12 | ||
| 18 | ASTM Class 6 | - | See scope document |
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 19 of 20
VIII. Time & Frequency
Parameter/Equipment Range CMC2, 7 (±) Comments
Frequency3 – Measure
DC to 3 GHz
1.7 parts in 107 Hz
Agilent 53132A
opt.10 conditioned by
a Datum 9390-6000
GPS
Frequency3 – Measuring
Equipment
DC to 600 MHz
1.7 parts in 107 Hz
Fluke 5520A/SC600
conditioned by a
Datum 9390-6000
GPS
Stopwatches / Timers3
(0 to 19.99) s/day
0.037 s/day
Timometer
1 This laboratory offers commercial dimensional testing/calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and % is the percent of reading unless otherwise stated.
6 In the statement of CMC, the contributions from “the best existing device” are not included. | to 3 GHz |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2332.01) Revised 2/16/2026 Page 20 of 20
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration. | ||
| 21 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Ohm-LabsPittsburgh, PA · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Process InstrumentsPittsburgh, PA · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation Powerlabs - Madison, PAMadison, PA · ~64 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- All American Scales & CalibrationParis, OH · ~78 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~82 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994