Instrument Calibration Solutions

413 Hopewell Avenue, 15001, Aliquippa, PA, United States

Visit website
A2LA 2332.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
21
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 21 scope lines.

A2LA certificate 2332.01 · 21 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 2 of 20 II. Dimensional Parameter/Equipment Range CMC2, 5, 7 (±) Comments Angle – Measure Up to 90° 10 arc sec Vision system Angle – Measuring Equipment6 (Protractor, Inclinometer, Levels) Up to 90° 1.8 arc sec Master angle blocks, master 90˚ square Bore Gages Up to 4 in (52 + 26L) Ring gages, surface plate Calipers3, 6 Up to 24 in (24 to 40) in 5 µin/in + 4.6 µin 4.7 µin/in + 4.5 µin Gage blocks Coating Thickness Gages Up to 60 mils 0.13 % + 0.14 mils Thickness standards End Rods Up to 40 in 2.3 µin/in + 14 µin LMU1000A Gage Blocks (0.05 to 1) in (1 to 4) in (4 to 20) in 2.2 µin/in + 2.4 µin 1.4 µin/in + 1.7 µin 1.9 µin/in + 0.6 µin Lab master, LMU1000A, master gage blocks Height Gage Up to 48 in (50 + 4.1L) µin Gage blocks, surface plate Indicators Up to 2 in 16 µin Lab master, LMU1000A, master gage blocks Measuring Microscopes – X-Y Axis Up to 12 in 3 µin/in + 65 µin 6 x 12 glass grid
to 90 °
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 3 of 20 Parameter/Equipment Range CMC2, 5 (±) Comments Micrometer3 Up to 1 in (1 to 4) in (4 to 24) in (24 to 40) in 4.0 µin/in + 10 µin 2.9 µin/in + 43 µin 2.9 µin/in + 77 µin 1.7 µin/in + 400 µin Gage blocks Optical Comparators3 – Linear Accuracy Angle X/Y Perpendicularity Magnification Up to 12 in 30 in chart (in decimal degree) Up to 3 in Up to 30 in chart 2.8 µin/in + 76 µin 0.022° 80 µin 0.003 in Max Levy glass grid Pins, Plug Gages, & Master Disk Up to 20 in 1.5 µin/in + 9.3 µin Lab master, LMU1000A, master gage blocks Radius Gages Up to 8 in 360 µin Vision system Ring Gages (0.125 to 0.25) in (0.25 to 1) in (1 to 3) in (3 to 15) in 11 µin 5.3 µin/in + 9.8 µin 1.0 µin/in + 14 µin 1.6 µin/in + 14 µin LMU1000A, master ring Surface Plates Grade AA, A, & B3 – Flatness Repeat Reading Up to 192 in DL Up to 0.002 in 5.3 µin + 0.51 µin/in 29 µin LDDM laser DL = diagonal length Repeat-o-meter Surface Roughness Meters & Profilometer (119.0 to 121.0) µin Ra 2.1 µin Roughness specimen Tape Measure Up to 100 ft 0.004 % + 0.0014 in LDDM laser, length calibration system
to 192 in
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 4 of 20 Parameter/Equipment Range CMC2 (±) Comments Thread Plugs – Simple Pitch Diameter Major Diameter Up to 8 in Up to 12 in 96 µin 2 µin/in + 56 µin LMU1000A, master gage blocks & thread wires Video Measuring Systems 3 – X-Y Axis Z Axis TurnCheck Height (Z Axis) Width (X-Y Axis) Up to 12 in Up to 18 in Up to 24 in Up to 4 in Up to 600 mm Up to 130 mm 3.7 µin/in + 34 µin 3.3 µin/in + 29 µin 3.2 µin/in + 35 µin 11 µin/in + 34 µin 0.71 µm 0.44 µm 6 x 12 glass grid 12 x 12 glass grid 18 x 24 glass grid Gage blocks Turncheck height gage Turncheck width gage III. Dimensional Testing/Calibration1 Parameter/Equipment Range CMC2 (±) Comments Length – 1 Dimensional9 – Measure Up to 240 in 1.3 µin/in + 1.5 µin LDDM laser Length – 2 Dimensional9 – Measure Up to 24 in DL 6.7 µin/in + 89 µin Vision system DL = diagonal length
to 8 in
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 5 of 20 IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage3, 6 – Generate (0 to 329.9999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (100 to 1020) V 20 nV/mV + 1000 nV 11 µV/V + 2 µV 12 µV/V + 20 µV 18 µV/V + 160 µV 18 µV/V + 1500 µV Fluke 5520A DC Voltage3 – Measure (0 to 120) mV (0 to 1.2) V (0 to 12) V (0 to 120) V (0 to 1050) V (0 to 10) kV (10 to 35) kV (35 to 70) kV (70 to 90) kV 6.4 nV/mV + 530 nV 5.2 µV/V + 0.53 µV 5.2 µV/V + 1.4 µV 7.4 µV/V + 53 µV 23 µV/V + 330 µV 0.05 % + 0.006 V 0.07 % + 0.06 V 0.12 % + 0.06 V 0.28 % + 0.1 V Agilent 3458A opt 2 Vitrek 4700 Vitrek HVL-35 Vitrek HVL-70 Vitrek HVL-150 DC Current3, 6 – Generate Clamp-On Meters (0 to 329.999) µA (0 to 3.299 99) mA (0 to 32.9999) mA (0 to 329.999) mA (0 to 1.099 99) A (1.1 to 2.999 99) A (0 to 10.9999) A (11 to 20.5) A (20 to 1000) A 0.015 % + 20 nA 0.01 % + 0.05 µA 0.01 % + 0.25 µA 0.01 % + 2.5 µA 0.02 % + 0.04 mA 0.039 % + 0.032 mA 0.051 % + 0.5 mA 0.095 % + 1.6 mA 0.29 % + 0.082 A Fluke 5520A Fluke 5520A w/ 50 turn coil DC Current3, 6 – Measure (0 to 120) nA (0 to 1.2) µA (0 to 12) µA (0 to 120) µA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.05) A 0.033 pA/nA + 52 pA 0.024 nA/µA + 0.052 nA 0.026 nA/µA + 0.087 nA 0.027 nA/µA + 0.76 nA 0.025 µA/mA + 0.0053 µA 0.026 µA/mA + 0.053 µA 0.046 µA/mA + 0.54 µA 0.13 mA/A + 0.012 mA Agilent 3458A opt 2
to 1020 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 6 of 20 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance3, 6 – Generate Fixed Points (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 1.0 mΩ 10.0 mΩ 100.0 mΩ 1.0 Ω 10.0 Ω 100.0 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 45 µΩ/Ω + 1000 µΩ 32 µΩ/Ω + 1400 µΩ 29 µΩ/Ω + 1400 µΩ 27 µΩ/Ω + 2100 µΩ 29 mΩ/kΩ + 1.6 mΩ 27 mΩ/kΩ + 21 mΩ 29 mΩ/kΩ + 16 mΩ 27 mΩ/kΩ + 210 mΩ 29 mΩ/kΩ + 160 mΩ 33 mΩ/kΩ + 2000 mΩ 32 Ω/MΩ + 2.3 Ω 60 Ω/MΩ + 30 Ω 130 Ω/MΩ + 43 Ω 250 Ω/MΩ + 2600 Ω 520 Ω/MΩ + 2900 Ω 3000 Ω/MΩ + 110 000 Ω 15 000 Ω/MΩ + 570 000 Ω 0.000 25 mΩ 0.0025 mΩ 0.025 mΩ 0.000 25 Ω 0.0025 Ω 0.025 Ω 24 mΩ 240 Ω 2.5 Ω 30 Ω 10 kΩ 920 kΩ 9.2 MΩ 140 MΩ 3.9 GΩ Fluke 5520A Fixed standard resistors Resistance3, 6 – Measure (0 to 12) Ω (0 to 120) Ω (0 to 1.2) kΩ (0 to 12) kΩ (0 to 120) kΩ (0 to 1.2) MΩ (0 to 12) MΩ (0 to 120) MΩ (0 to 1.2) GΩ 18 µΩ/Ω + 70 µΩ 15 µΩ/Ω + 700 µΩ 12 mΩ/kΩ + 2.4 mΩ 12 mΩ/kΩ + 24 mΩ 12 mΩ/kΩ + 240 mΩ 18 Ω/MΩ + 3.3 Ω 61 Ω/MΩ + 120 Ω 610 Ω/MΩ + 2100 Ω 5700 kΩ/GΩ + 110 kΩ Agilent 3458A opt 2
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 7 of 20 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTDs3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.08 °C 0.08 °C 0.09 °C 0.11 °C 0.12 °C 0.14 °C 0.24 °C 0.08 °C 0.08 °C 0.1 °C 0.11 °C 0.12 °C 0.14 °C 0.26 °C 0.07 °C 0.08 °C 0.09 °C 0.1 °C 0.1 °C 0.11 °C 0.12 °C 0.24 °C 0.07 °C 0.07 °C 0.07 °C 0.08 °C 0.17 °C 0.16 °C 0.16 °C 0.19 °C 0.07 °C 0.08 °C 0.08 °C 0.09 °C 0.1 °C 0.1 °C 0.11 °C 0.13 °C Fluke 5520A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 8 of 20 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTDs3 – (cont) Pt 385, 1000 Ω Ni 120, 120 Ω Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.07 °C 0.07 °C 0.07 °C 0.08 °C 0.09 °C 0.09 °C 0.09 °C 0.24 °C 0.1 °C 0.1 °C 0.15 °C 0.32 °C Fluke 5520A Electrical Simulation of Thermocouples3 – Type B Type C Type E (250 to 349) °C (350 to 444) °C (445 to 579) °C (580 to 749) °C (750 to 999) °C (1000 to 1820) °C (0 to 249) °C (250 to 999) °C (1000 to 1499) °C (1500 to 1799) °C (1800 to 1999) °C (2000 to 2249) °C (2250 to 2315) °C (-270 to -244) °C (-245 to -194) °C (-195 to -154) °C (-155 to -90) °C (-90 to 14) °C (15 to 889) °C (890 to 1000) °C 0.95 °C 0.74 °C 0.58 °C 0.45 °C 0.37 °C 0.29 °C 0.20 °C 0.16 °C 0.18 °C 0.21 °C 0.23 °C 0.29 °C 0.32 °C 1.20 °C 0.18 °C 0.10 °C 0.08 °C 0.07 °C 0.06 °C 0.07 °C Ectron 1140A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 9 of 20 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples3 – (cont) Type J Type K Type N Type R Type S Type T (-210 to -179) °C (-180 to -119) °C (-120 to -49) °C (-50 to 989) °C (990 to 1200) °C (-270 to -254) °C (-255 to -194) °C (-195 to -114) °C (-115 to -54) °C (-55 to 999) °C (1000 to 1372) °C (-270 to -259) °C (-260 to -199) °C (-200 to -139) °C (-140 to -69) °C (-70 to 24) °C (25 to 159) °C (160 to 1300) °C (-50 to -29) °C (-30 to 44) °C (45 to 159) °C (160 to 379) °C (380 to 774) °C (775 to 1768) °C (-50 to -29) °C (-30 to 44) °C (45 to 159) °C (160 to 379) °C (380 to 774) °C (775 to 1768) °C (-270 to -254) °C (-255 to -239) °C (-240 to -209) °C (-210 to -149) °C (-150 to -39) °C (-40 to 99) °C (100 to 400) °C 0.12 °C 0.10 °C 0.08 °C 0.07 °C 0.07 °C 2.20 °C 0.70 °C 0.12 °C 0.09 °C 0.07 °C 0.08 °C 5.0 °C 1.0 °C 0.23 °C 0.15 °C 0.12 °C 0.10 °C 0.09 °C 0.65 °C 0.55 °C 0.40 °C 0.30 °C 0.26 °C 0.22 °C 0.62 °C 0.56 °C 0.40 °C 0.33 °C 0.29 °C 0.26 °C 1.8 °C 0.49 °C 0.30 °C 0.18 °C 0.12 °C 0.08 °C 0.07 °C Ectron 1140A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 10 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3, 6 – Generate (1 to 32.999) mV (33 to 329.999) mV (330 mV to 3.3) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.079 % + 6 µV 0.015 % + 6 µV 0.021 % + 6.1 µV 0.1 % + 6.1 µV 0.36 % + 12 µV 0.79 % + 50 µV 0.031 % + 7.8 µV 0.014 % + 8.2 µV 0.016 % + 8.8 µV 0.034 % + 8.9 µV 0.081 % + 32 µV 0.2 % + 74 µV 0.029 % + 0.0o mV 0.015 % + 0.06 mV 0.019 % + 0.068 mV 0.029 % + 0.056 mV 0.069 % + 0.13 mV 0.24 % + 0.6 mV 0.031 % + 0.67 mV 0.015 % + 0.6 mV 0.024 % + 0.6 mV 0.034 % + 0.67 mV 0.089 % + 1.7 mV 0.019 % + 2.2 mV 0.02 % + 6.4 mV 0.025 % + 5.7 mV 0.032 % + 5.6 mV 0.2 % + 54 mV 0.03 % + 9.6 mV 0.026 % + 9.8 mV 0.03 % + 9.6 mV Fluke 5520A AC Voltage3,6 – Measure (1.2 to 12) mV (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.034 % + 3.5 µV 0.023 % + 1.2 µV 0.034 % + 1.3 µV 0.11 % + 1.3 µV 0.58 % + 1.2 µV 4.6 % + 2.2 µV Agilent 3458A opt 2
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 11 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3, 6 – Measure (cont) (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (70 to 700) V Up to 10 kV (10 to 30) kV (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz (40 to 100) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (30 to 200) Hz (30 to 200) Hz 0.0096 % + 4.4 µV 0.009 % + 2.2 µV 0.017 % + 2.2 µV 0.041 % + 2.1 µV 0.098 % + 2.2 µV 0.35 % + 12 µV 1.2 % + 11 µV 1.7 % + 11 µV 0.0096 % + 0.044 mV 0.009 % + 0.022 mV 0.065 % + 0.0089 mV 0.037 % + 0.022 mV 0.098 % + 0.022 mV 0.35 % + 0.12 mV 1.2 % + 0.11 mV 1.7 % + 0.11 mV 0.0096 % + 0.44 mV 0.009 % + 0.22 mV 0.017 % + 0.22 mV 0.036 % + 0.22 mV 0.089 % + 0.33 mV 0.35 % + 1.1 mV 1.2 % + 1.1 mV 1.7 % + 1.1 mV 0.024 % + 4.6 mV 0.023 % + 2.3 mV 0.024 % + 2.3 mV 0.041 % + 2.2 mV 0.14 % + 2.2 mV 0.47 % + 11 mV 1.7 % + 11 mV 0.048 % + 46 mV 0.047 % + 23 mV 0.07 % + 23 mV 0.14 % + 23 mV 0.35 % + 22 mV 0.16 % + 0.006 V 0.14 % + 0.06 V Agilent 3458A opt 2 Vitrek 4700 Vitrek HVL-35
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 12 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3,6 – Measure (cont) (30 to 50) kV (50 to 70) kV (30 to 100) Hz < 65 Hz 0.16 % + 0.06 V 0.69 % + 0.06 V Vitrek HVL-70 Vitrek HVL-150 AC Current3,6 – Generate (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz 0.16 % + 75 nA 0.12 % + 76 nA 0.096 % + 82 nA 0.24 % + 110 nA 0.62 % + 160 nA 1.2 % + 310 nA 0.15 % + 0.12 µA 0.096 % + 0.12 µA 0.078 % + 0.13 µA 0.16 % + 0.17 µA 0.39 % + 0.22 µA 0.77 % + 0.44 µA 0.14 % + 1.6 µA 0.071 % + 1.6 µA 0.031 % + 1.7 µA 0.062 % + 1.7 µA 0.16 % + 2.3 µA 0.33 % + 2.2 µA 0.14 % + 16 µA 0.071 % + 16 µA 0.031 % + 17 µA 0.079 % + 39 µA 0.15 % + 79 µA 0.32 % + 160 µA 0.14 % + 0.086 mA 0.039 % + 0.081 mA 0.47 % + 0.76 mA 1.9 % + 3.6 mA 0.14 % + 0.037 mA 0.047 % + 0.079 mA 0.48 % + 0.63 mA 1.9 % + 3.6 mA 0.048 % + 1.6 mA 0.076 % + 1.6 mA 2.4 % + 1.5 mA Fluke 5520A
30 to 50 kV
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 13 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Generate (cont) (11 to 20.5) A Clamp Meters: (20 to 1000) A (10 to 45) Hz (45 to 1000) Hz (1 to 5) kHz (45 to 65) Hz 0.095 % + 3.6 mA 0.12 % + 4.3 mA 2.3 % + 5.3 mA 0.4 % + 0.078 A Fluke 5520A & 50 turn coil AC Current3,6 – Measure (6 to 120) µA (0.06 to 1.2) mA (0.6 to 12) mA (6 to 120) mA (0.0525 to 1.05) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz 0.46 % + 35 nA 0.17 % + 35 nA 0.071 % + 35 nA 0.071 % + 35 nA 0.47 % + 0.23 µA 0.17 % + 0.24 µA 0.073 % + 0.23 µA 0.036 % + 0.23 µA 0.073 % + 0.23 µA 0.47 % + 0.46 µA 0.65 % + 1.7 µA 0.47 % + 2.3 µA 0.17 % + 2.4 µA 0.073 % + 2.3 µA 0.036 % + 2.3 µA 0.073 % + 2.3 µA 0.47 % + 4.6 µA 0.65 % + 17 µA 0.47 % + 23 µA 0.17 % + 24 µA 0.073 % + 23 µA 0.036 % + 23 µA 0.073 % + 23 µA 0.47 % + 46 µA 0.65 % + 170 µA 0.46 % + 0.24 mA 0.19 % + 0.23 mA 0.092 % + 0.23 mA 0.11 % + 0.23 mA 0.35 % + 0.24 mA 1.2 % + 0.47 mA Agilent 3458A opt 2
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 14 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.5 % + 0.01 nF 0.5 % + 0.01 nF 0.5 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.1 nF 0.25 % + 0.1 nF 0.25 % + 0.3 nF 0.25 % + 1.0 nF 0.25 % + 3.0 nF 0.25 % + 10 nF 0.4 % + 30 nF 0.45 % + 100 nF 0.45 % + 300 nF 0.45 % + 1.0 µF 0.45 % + 3.0 µF 0.45 % + 10 µF 0.75 % + 30 µF 1.1 % + 100 µF Fluke 5520A Parameter/Equipment Range CMC2 (±) Comments Oscilloscope3 – Amplitude – 50 Ω Load 1 MΩ Load Leveled Sine Wave Amplitude – 5 mV to 5.5 V 4 mV to 3.5 V Flatness – Relative to 50 kHz 5 mV to 5.5 V 4 mV to 3.5 V (-6.6 to 6.6) V (-130 to 130) V 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 0.25 % of output + 40 µV 0.05 % of output + 40 µV 2.0 % of output + 300 µV 3.5 % of output + 300 µV 4.0 % of output + 300 µV 6.0 % of output + 300 µV 6.0 % of output + 300 µV 1.5 % of output + 100 µV 2.0 % of output + 100 µV 4.0 % of output + 100 µV 5.0 % of output + 100 µV Fluke 5522A/SC1100
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 15 of 20 Parameter/Equipment Range CMC2 (±) Comments Oscilloscope3 – (cont) Time Marker6 – 50 Ω Load Edge6 – Rise Time 50 Ω Load 5 s to 50 ms 20 ms to 1 ns 1 kHz to 2 MHz (200 to 300) ps (2 to 10) MHz (200 to 350) ps (25 + 1000t) µs/s 2.5 µs/s 100 ps 100 ps Fluke 5520A/SC600 t = time in seconds V. Electrical – RF Microwave Parameter/Equipment Range CMC2, 5, 7 (±) Comments Amplitude Flatness3 – Measure (Relative to 100 kHz) (-3 to 0) dBm 100 kHz to 80 MHz 0.042 dB R&S NRP-Z51 power sensor Absolute Power3 – Measure (-13 to 20) dBm 100 kHz to 80 MHz 0.042 dB R&S NRP-Z51 power sensor VI. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Balance & Scales Up to 30 kg Up to 1000 lb 0.0002 % + 0.026 mg 0.016 % + 0.000 05 lb Class F weight
-3 to 0 dBm
16ASTM Class 6 & 7-to 50000 lbf
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 17 of 20 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Indirect Verification of Rockwell Hardness & Rockwell Superficial Hardness Testers (cont) HR15TW: (60 to 80) HR15TW (80 to 86) HR15TW (86 to 93) HR15TW HR30TW: (15 to 56) HR30TW (56 to 69) HR30TW (69 to 83) HR30TW 0.29 HR15TW 0.58 HR15TW 0.53 HR15TW 0.48 HR30TW 0.41 HR30TW 0.45 HR30TW Rockwell hardness test blocks Pressure3 – Measuring Equipment Pneumatic, Absolute Pneumatic Vacuum Water (0.13 to 14.7) psia (14.7 to 15.7) psia (15.7 to 21.1) psia (21.1 to 22.7) psia (22.7 to 30.7) psia (4 to 860) inH 2O (0 to 1) psi (1 to 6.4) psi (3 to 500) psi (501 to 1500) psi (1501 to 5000) psi (0 to 2) inH 2O (0 to -15) psi (0 to -1) psi (10 to 10 000) psi 0.0025 psia 0.0018 psia 0.0019 psia 0.0020 psia 0.0026 psia 0.02 % 0.000 12 psi 0.0008 psi 0.01 % + 0.000 06 psi 0.012 % + 0.003 psi 0.012 % + 0.001 psi 0.000 48 inH 2O 0.002 psi 0.0001 psi 0.01 % + 0.0006 psi Mensor CPC6000 transducers PKII 654WC-SS Mensor CPC6050 transducers T3500 deadweight Mensor CPC8000 transducer Dwyer 1430 microtector Mensor CPC6000 transducer Fluke P3224 Torque3 – Measuring Equipment (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (60 to 600) lbf·ft 0.25 % + 0.023 lbf·in 0.25 % + 0.24 lbf·in 0.27 % + 0.27 lbf·in 0.27 % + 0.067 lbf·ft 0.6 % Snap-On TTC400 system Snap-On TTC12
18ASTM Class 6-See scope document
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 19 of 20 VIII. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Frequency3 – Measure DC to 3 GHz 1.7 parts in 107 Hz Agilent 53132A opt.10 conditioned by a Datum 9390-6000 GPS Frequency3 – Measuring Equipment DC to 600 MHz 1.7 parts in 107 Hz Fluke 5520A/SC600 conditioned by a Datum 9390-6000 GPS Stopwatches / Timers3 (0 to 19.99) s/day 0.037 s/day Timometer  1 This laboratory offers commercial dimensional testing/calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches and % is the percent of reading unless otherwise stated. 6 In the statement of CMC, the contributions from “the best existing device” are not included.
to 3 GHz
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 20 of 20 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration.
21ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

413 Hopewell Avenue, Aliquippa, PA, 15001, US

40.61024, -80.26773

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.