Ohm-Labs

611 E. Carson Street, 15203-1021, Pittsburgh, PA, United States

Visit website
A2LA 2481.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2481.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-100 to 1000000
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 2 of 4 Parameter/Equipment Range3 CMC2, 6 (±) Comments Resistance – Measure (cont) (1 to <10) Ω (10 to <100) Ω (100 to <1000) Ω (1 to 10) kΩ (>10 to 100) kΩ (>0.1 to 1) MΩ (>1 to 10) MΩ (>10 to 100) MΩ (>100 to 1000) MΩ (>1 to 10) GΩ (>10 to 100) GΩ (>100 to 1000) GΩ (>1 to 10) TΩ (0 to 10) Ω (>10 to 100) Ω (>100 to 1000) Ω (>1 to 10) kΩ (>10 to 100) kΩ (>100 to 1000) kΩ (>1 to 10) MΩ (>10 to 100) MΩ 0.12 μΩ/Ω 0.15 μΩ/Ω 0.15 μΩ/Ω 0.12 μΩ/Ω 0.30 μΩ/Ω 1.8 μΩ/Ω 3.5 μΩ/Ω 6.0 µΩ/Ω 11 µΩ/Ω 20 µΩ/Ω 50 µΩ/Ω 0.010 % of rdg 0.020 % of rdg 35 µΩ/Ω + 0.06 mΩ 20 µΩ/Ω + 0.6 mΩ 15 µΩ/Ω + 0.6 mΩ 15 µΩ/Ω + 6 mΩ 20 µΩ/Ω + 60 mΩ 25 µΩ/Ω + 3 Ω 70 µΩ/Ω + 120 Ω 600 µΩ/Ω + 1200 Ω MI 6242D bridge Comparison with guarded dual source bridge Measurement with Agilent 3458A DMM AC Voltage – Measure, (50 & 60) Hz (0 to 10) V (>10 to 100) V (>100 to 500) V 0.020 % of rdg + 0.20 mV 0.030 % of rdg + 2.0 mV 0.050 % of rdg + 22 mV Agilent 3458A DMM AC Voltage – Measure, (50 & 60) Hz (0.5 to 1.0) kV (>1.0 to 10) kV (>10 to 80) kV (>80 to 100) kV 0.030 % of rdg + 0.050 V 0.030 % of rdg + 0.50 V 0.030 % of rdg + 5.0 V 0.040 % of rdg + 4.0 V Agilent 3458A DMM & MI 2500A divider Agilent 3458A DMM & Ohm-Lab’s HVT divider AC High Voltage Ratio – Applied Voltage – Measure (100 to 100 000):1 (0.1 to 100) kV @ (50 or 60) Hz 0.050 % of ratio Agilent 3458A DMMs, MI 2500A divider, Ohm-Labs HVT divider
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 3 of 4 Parameter/Range Frequency CMC2, 6 (±) Comments AC – DC Difference – Measure (2 to 10) mA (>10 to 100) mA (>0.1 to 1.0) A (>1.0 to 2) A (>2 to 20) A (>20 to 50) A (>50 to 100) A (0.2 to 1.0) V (>1 to 10) V (>10 to 50) V (>50 to 200) V (>200 to 500) V 10 Hz to 50 kHz >50 kHz to 1 MHz 10 Hz to 100 kHz 10 Hz to 100 kHz (10 to 20) Hz >20 Hz to 100 kHz (10 to 20) Hz >20 Hz to 50 kHz (>50 to 100) kHz 10 Hz to 30 kHz (>30 to 50) kHz (>50 to 70) kHz (>70 to 100) kHz 10 Hz to 50 kHz (>50 to 70) kHz (>70 to 100) kHz 10 Hz to 50 kHz >50 kHz to 1 MHz 10 Hz to 100 kHz >100 kHz to 1 MHz 10 Hz to 100 kHz >100 kHz to 1 MHz (10 to 100) Hz (>0.01 to 100) kHz (10 to 100) Hz (>0.01 to 100) kHz 11 μA/A 16 μA/A 11 μA/A 15 μA/A 18 μA/A 15 μA/A 22 μA/A 28 μA/A 34 μA/A 28 μA/A 33 μA/A 37 μA/A 42 μA/A 45 μA/A 65 μA/A 85 μA/A 11 μV/V 16 μV/V 12 μV/V 22 μV/V 15 μV/V 30 μV/V 18 μV/V 15 μV/V 28 μV/V 22 μV/V Comparison with thermal voltage converter Comparison with coaxial AC current shunts using thermal voltage converters Comparison with thermal voltage converter Comparison with coaxial AC resistors using thermal voltage converters
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2481.01) Revised 12/16/2024 Page 4 of 4 II. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measure (18 to 30) °C (0 to 200) °C 0.020 °C 0.20 °C Measurement with Fluke 1504 thermometer Measurement with Isotech MilliK thermometer ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Where ranges are not specified, the CMC stated is for the cardinal points only. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

611 E. Carson Street, Pittsburgh, PA, 15203-1021, US

40.44142, -80.00390

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.