JM Test Systems
2152 University Drive, Suite #2, 15465, Mt. Braddock, PA, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 1995.07 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage
3 – Generate
(0 to 330) mV
(0.33 to 33) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
47 µV/V + 3 µV
39 µV/V + 5 µV
39 µV/V + 50 µV
43 µV/V + 0.5 mV
43 µV/V + 1.5 mV
Fluke 5502A
DC Current
3 – Generate
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
0.012 % + 0.02 µA
0.010 % + 0.05 µA
78 µA/A + 0.25 µA
78 µA/A + 2.5 µA
0.030 % + 44 µA
0.030 % + 44 µA
0.047 % + 0.5 mA
0.078 % + 0.75 mA
0.25 % + 0.002 A
0.26 % + 0.015 A
0.27 % + 0.05 A
Fluke 5502A
Fluke 5502A, 50
turn coil
Resistance – Generate,
Fixed Points3, 4, 8
0.1 mΩ
0.5 mΩ
1 mΩ
2 mΩ
5 mΩ
10 mΩ
20 mΩ
50 mΩ
0.1 Ω
0.2 Ω
0.5 Ω
1 Ω
0.39 µΩ
1.6 µΩ
3.2 µΩ
6.3 µΩ
15 µΩ
29 µΩ
28 µΩ
66 µΩ
0.12 mΩ
0.25 mΩ
0.60 mΩ
1.2 mΩ
Empro shunts | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 3 of 14
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Resistance
3 – Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 33) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
0.011 % + 0.001 Ω
95 µΩ/Ω + 0.0015 Ω
70 µΩ/Ω + 0.0014 Ω
70 µΩ/Ω + 0.002 Ω
70 µΩ/Ω + 0.002 Ω
70 µΩ/Ω + 0.02 Ω
70 µΩ/Ω + 0.02 Ω
70 µΩ/Ω + 0.2 Ω
86 µΩ/Ω + 0.2 Ω
93 µΩ/Ω + 2 Ω
0.012 % + 2 Ω
0.012 % + 30 Ω
0.047 % + 50 Ω
0.078 % + 2.5 kΩ
0.39 % + 3 kΩ
0.39 % + 0.1 MΩ
1.2 % + 0.5 MΩ
Fluke 5502A
Resistance – Generate,
Fixed Points
3, 4, 8 for
Insulation Testers
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
0.012 MΩ
0.12 MΩ
1.2 MΩ
0.012 GΩ
0.24 GΩ
5.8 GΩ
Fixed resistors
DC Power
3 – Generate
Up to 109 µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 109) W
(109 to 337) W
(337 to 990) W
(0.99 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
5.5 W to 16.8 kW
(16.8 to 153) kW
(153 to 1045) kW
0.019 %
0.013 %
0.010 %
0.0090 %
0.0090 %
0.0090 %
0.010 %
0.010 %
0.032 %
0.032 %
0.052 %
0.080 %
0.19 %
0.20 %
0.21 %
Fluke 5502A
Fluke 5502A + 50
turn coil | ||
| 4 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 4 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage
3 – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(0.01 to 10) Hz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
3.9 % + 170 µV
0.12 % + 20 µV
0.078 % + 20 µV
0.12 % + 20 µV
0.16 % + 20 µV
0.27 % + 33 µV
0.78 % + 60 µV
3.9 % + 1.7 mV
0.039 % + 20 µV
0.023 % + 20 µV
0.054 % + 20 µV
0.078 % + 40 µV
0.18 % + 170 µV
0.39 % + 330 µV
3.9 % + 17 mV
0.042 % + 60 µV
0.023 % + 60 µV
0.054 % + 60 µV
0.078 % + 60 µV
0.18 % + 0.2 mV
0.39 % + 0.9 mV
3.9 % + 0.17 V
0.042 % + 0.8 mV
0.023 % + 0.6 mV
0.054 % + 0.6 mV
0.078 % + 0.6 mV
0.18 % + 2 mV
0.039 % + 3 mV
0.062 % + 9 mV
0.070 % + 9 mV
0.093 % + 9 mV
0.19 % + 80 mV
0.039 % + 20 mV
0.062 % + 20 mV
0.070 % + 20 mV
Fluke 5502A | See scope document |
| 5 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 5 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current3 – Generate
(0.029 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.16 % + 0.1 µA
0.12 % + 0.1 µA
0.099 % + 0.1 µA
0.23 % + 0.15 µA
0.62 % + 0.2 µA
1.2 % + 0.4 µA
0.16 % + 0.15 µA
0.099 % + 0.15 µA
0.08 % + 0.15 µA
0.16 % + 0.2 µA
0.39 % + 0.3 µA
0.78 % + 0.6 µA
0.14 % + 2 µA
0.072 % + 2 µA
0.036 % + 2 µA
0.065 % + 2 µA
0.16 % + 3 µA
0.31 % + 4 µA
0.14 % + 20 µA
0.072 % + 20 µA
0.036 % + 20 µA
0.08 % + 50 µA
0.16 % + 0.1 mA
0.31 % + 0.2 mA
0.15 % + 0.1 mA
0.043 % + 0.1 mA
0.05 % + 1 mA
1.9 % + 5 mA
0.15 % + 0.1 mA
0.05 % + 0.1 mA
0.47 % + 1 mA
1.9 % + 5 mA
0.05 % + 2 mA
0.08 % + 2 mA
2.3 % + 2 mA
0.095 % + 5 mA
0.12 % + 5 mA
2.3 % + 5 mA
Fluke 5502A | See scope document |
| 6 | - | AC Current; AC PowerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 6 of 14
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current3 – Generate
(cont)
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
100 Hz to 1 kHz
(10 to 100) Hz
(100 to 400) Hz
(10 to 100) Hz
(100 to 400) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.19 % + 0.2 µA
0.47 % + 0.5 µA
0.19 % + 0.3 µA
0.47 % + 0.8 µA
0.065 % + 4 µA
0.16 % + 10 µA
0.065 % + 40 µA
0.16 % + 0.1 mA
0.095 % + 0.2 mA
0.23 % + 1 mA
0.095 % + 2 mA
0.78 % + 5 mA
0.29 % + 0.003 A
0.81 % + 0.003 A
0.30 % + 0.025 A
0.83 % + 0.027 A
0.30 % + 0.09 A
1.2 % + 0.1 A
Fluke 5502A with
LCOMP on
Fluke 5502A, 50 turn
coil
AC Power3 – Generate
(45 to 65 Hz, PF=1)
Up to 10.9 µW
(10.9 to 109) µW
(0.109 to 1.09) mW
(1.09 to 10.9) mW
(10.9 to 109) mW
(0.109 to 1.09) W
(1.09 to 10.9) W
(10.9 to 37) W
(37 to 337) W
(0.337 to 1.12) kW
(1.12 to 3.06) kW
(3.06 to 11.2) kW
(11.2 to 20.9) kW
0.55 W to 16.8 kW
(16.8 to 1045) kW
0.19 %
0.13 %
0.090 %
0.051 %
0.049 %
0.049 %
0.049 %
0.058 %
0.059 %
0.066 %
0.067 %
0.080 %
0.13 %
0.23 %
0.25 %
Fluke 5502A
Fluke 5502A + 50 turn
coil | See scope document |
| 7 | - | Capacitance; Thermocouple IndicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 7 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Capacitance3 – Source
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.39 % + 0.01 nF
0.39 % + 0.01 nF
0.39 % + 0.01 nF
0.20 % + 0.01 nF
0.19 % + 0.1 nF
0.19 % + 0.1 nF
0.20 % + 0.3 nF
0.21 % + 1 nF
0.20 % + 3 nF
0.21 % + 10 nF
0.32 % + 30 nF
0.36 % + 0.1 µF
0.35 % + 0.3 µF
0.36 % + 1 µF
0.42 % + 3 µF
0.40 % + 10 µF
0.76 % + 30 µF
0.85 % + 100 µF
Fluke 5502A
Electrical Calibration of
Thermocouple Indicators
3 –
Generate & Measure
Type E
Type J
Type K
Type N
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.21 °C
0.31 °C
0.31 °C
0.18 °C
0.16 °C
0.15 °C
0.21 °C
Fluke 5502A | See scope document |
| 8 | - | Thermocouple Indicators; RTD Indicators; Phase IndicatorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 8 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Electrical Calibration of
Thermocouple Indicators
3 –
Generate & Measure (cont)
Type T
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.49 °C
0.20 °C
0.13 °C
0.12 °C
Fluke 5502A
Electrical Calibration of
RTD Indicators
3 – Generate
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.04 °C
0.04 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.18 °C
Fluke 5502A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Electrical Calibration of
Phase Indicators
3 – Source
Only
Up to 90°
(10 to 65) Hz
(65 to 500)Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to30) kHz
0.18° Phase
1.0° Phase
2.3° Phase
6.9° Phase
12° Phase
17° Phase
Fluke 5502A | - |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 9 of 14
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
DC Voltage
3 – Measure
DC High Voltage
3, 4 –
Generate & Measure
(0 to 100) mV
(0.10 to 1.0) V
(1.0 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 100) kV
11 µV/V + 0.3 µV
10 µV/V + 0.3 µV
10 µV/V + 0.5 µV
13 µV/V + 30 µV
14 µV/V + 100 µV
1.2 %
Agilent 3458A
Phenix KVM 200A
Resistance
3 – Measure
Up to 10 Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
10 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 100) GΩ
21 µΩ/Ω + 50 µΩ
18 µΩ/Ω + 0.5 mΩ
17 µΩ/Ω + 0.5 mΩ
16 µΩ/Ω + 5 mΩ
19 µΩ/Ω + 50 mΩ
24 µΩ/Ω + 2 Ω
70 µΩ/Ω + 100 Ω
0.060 % + 1 kΩ
77 μΩ/Ω
0.54 %
0.70 %
Agilent 3458A
Voltage source & µA
range of 3458A
DC Current3 – Measure
Up to 100 µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
35 µA/A + 0.8 nA
35 µA/A + 5 nA
40 µA/A + 50 nA
53 µA/A + 0.5 µA
0.018 % + 10 µA
0.12 %
0.14 %
0.32 %
0.39 %
Agilent 3458A
Empro shunts, DMM | ||
| 10 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 10 of 14
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
(1 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.051 % + 3 µV
0.056 % + 1.1 µV
0.083 % + 1.1 µV
0.46 % + 1.1 µV
0.78 % + 1.1 µV
4.7 % + 2 µV
0.013 % + 4 µV
0.016 % + 2 µV
0.027 % + 2 µV
0.12 % + 2 µV
0.23 % + 2 µV
0.41 % + 10 µV
1.2 % + 10 µV
0.011 % + 40 µV
0.016 % + 20 µV
0.024 % + 20 µV
0.041 % + 20 µV
0.11 % + 20 µV
0.36 % + 100 µV
1.2 % + 100 µV
0.029 % + 0.4 mV
0.012 % + 0.2 mV
0.020 % + 0.2 mV
0.037 % + 0.2 mV
0.095 % + 0.2 mV
0.36 % + 1 mV
1.2 % + 1 mV
0.025 % + 4 mV
0.025 % + 2 mV
0.026 % + 2 mV
0.048 % + 2 mV
0.15 % + 2 mV
0.47 % + 10 mV
1.7 % + 10 mV
Agilent 3458A | See scope document |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 11 of 14
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage3 – Measure
(cont)
(100 to 700) V
(0.7 to 6) kV
(6 to 80) kV
(10 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(DC to 500) Hz
60 Hz
0.048 % + 40 mV
0.048 % + 20 mV
0.070 % + 20 mV
0.14 % + 20 mV
0.35 % + 20 mV
1.4 %
1.6 %
Agilent 3458A
Fluke 80K-6, DMM
Phenix KVM 200A
AC Current3 – Measure
Up to 100 μA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 10) kHz
0.46 % + 0.03 µA
0.18 % + 0.03 µA
0.074 % + 0.03 µA
0.074 % + 0.03 µA
0.46 % + 0.2 µA
0.18 % + 0.2 µA
0.076 % + 0.2 µA
0.047 % + 0.2 µA
0.074 % + 0.2 µA
0.46 % + 2 µA
0.18 % + 2 µA
0.077 % + 2 µA
0.048 % + 2 µA
0.075 % + 2 µA
0.46 % + 20 µA
0.18 % + 20 µA
0.077 % + 20 µA
0.049 % + 20 µA
0.075 % + 20 µA
0.47 % + 200 µA
0.20 % + 200 µA
0.12 % + 200 µA
0.14 % + 200 µA
0.35 % + 200 µA
Agilent 3458A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 12 of 14
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current3 – Measure
(cont)
(1 to 10) A
(10 to 50) A
(50 to 200) A
(200 to 1000) A
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
0.12 %
0.14 %
0.32 %
0.39 %
Empro shunts, DMM
III. Mechanical
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Torque Devices
5 lbf-in to 2000 lbf-ft
0.94 %
AWS torque testers
Pressure
(Pneumatic)
3 –
Measuring Equipment
Calibration of
Transfer Standards &
Pressure Devices
Absolute
Gauge & Differential
(0.3 to 15) psia
(15 to 50) psia
(0.14 to 300) psi
(-15 to 3000) psi
0.0035 psia
0.015 psia
0.0081 %
0.011 % + 0.6R
Mensor CPG 2300
RK-300/1100WC
Fluke 6270 with
PM500 modules
Pressure
(Hydraulic)
3 –
Measuring Equipment
(25 to 15 000) psi
0.018 %
Ametek Type T
deadweight tester | ||
| 13 | - | Temperature; Frequency; Time IntervalShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 13 of 14
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature3 – Measure
(-38 to 0.0) °C
(0 to 156) °C
(156 to 420) °C
(420 to 660) °C
0.019 °C
0.023 °C
0.052 °C
0.099 °C
PRT & readout
Temperature3 –
Measuring Equipment
(-25 to 0) °C
(0 to 156) °C
(156 to 250) °C
0.013 °C
0.019 °C
0.051 °C
PRT, readout, bath
V. Time & Frequency
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Frequency – Measuring
Equipment
3, 4
0.1 Hz to 10 MHz
0.01 Hz to 2 MHz
2.4 parts in 10
7
29 μHz/Hz
Keysight 3325B ref.
to Fluke PM6680
Fluke 5502A
Frequency – Measure
3, 4
0.1 Hz to 225 MHz
2.4 parts in 10
7
Fluke PM 6680
Time Interval
3 – Timers &
Stop Watches
Time Base
7
Totalize Method
Up to 24 hours
Up to 24 hours
0.043 seconds
0.12 seconds/day
NIST SP 960-12
Fluke PM6680
Fluke PM6680,
function generator
_______________________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability (CMC) is th e smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal Generate. Calibration and Measurement
Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence,
usually using a coverage factor of k = 2. The actual measurement un certainty of a specific calibration
performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device
and to influences from the circumstances of the specific calibration. | - |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1995.07) 05/14/2026 Page 14 of 14
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. Field environmental conditions are limited to 15 °C to 30
°C and <80% relative humidity to 30 °C.
4 Fluke 5502A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and assuming
the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5
oC. For Resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. For AC
Current, CMCs are determined with the LCOMP off and ON. CMCs are also based upon 1-year floor
specifications. CMCs are expressed as either a specific value that covers the full range or as a fraction of
the reading plus a fixed floor specification.
5 Agilent 3458A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and an auto
calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.) CMCs
are also based upon 1-year floor specifications. CMCs are expressed as either a specific value that covers
the full range or as a combination of a percent or the fraction of the reading/output plus a range
specification.
6 In the statement of CMC, percentages are percen tages of reading, unless otherwise indicated, and R
is the resolution of the Device Under Test.
7 Applicable when the internal time base (oscillator) of the device under test is/can be measured directly
by the frequency counter.
8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 In the statement of CMC, L is the numerical values of the nominal length measured in inches. | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
2 other sites in this organization
Labs with overlapping accredited scope in United States
- Constellation Powerlabs - Madison, PAMadison, PA · ~34 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ohm-LabsPittsburgh, PA · ~63 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Process InstrumentsPittsburgh, PA · ~63 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsAliquippa, PA · ~91 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~160 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.