JM Test Systems

2152 University Drive, Suite #2, 15465, Mt. Braddock, PA, United States

Visit website
A2LA 1995.07ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 1995.07 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage 3 – Generate (0 to 330) mV (0.33 to 33) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 47 µV/V + 3 µV 39 µV/V + 5 µV 39 µV/V + 50 µV 43 µV/V + 0.5 mV 43 µV/V + 1.5 mV Fluke 5502A DC Current 3 – Generate Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 0.012 % + 0.02 µA 0.010 % + 0.05 µA 78 µA/A + 0.25 µA 78 µA/A + 2.5 µA 0.030 % + 44 µA 0.030 % + 44 µA 0.047 % + 0.5 mA 0.078 % + 0.75 mA 0.25 % + 0.002 A 0.26 % + 0.015 A 0.27 % + 0.05 A Fluke 5502A Fluke 5502A, 50 turn coil Resistance – Generate, Fixed Points3, 4, 8 0.1 mΩ 0.5 mΩ 1 mΩ 2 mΩ 5 mΩ 10 mΩ 20 mΩ 50 mΩ 0.1 Ω 0.2 Ω 0.5 Ω 1 Ω 0.39 µΩ 1.6 µΩ 3.2 µΩ 6.3 µΩ 15 µΩ 29 µΩ 28 µΩ 66 µΩ 0.12 mΩ 0.25 mΩ 0.60 mΩ 1.2 mΩ Empro shunts
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 3 of 14 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Resistance 3 – Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 33) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.011 % + 0.001 Ω 95 µΩ/Ω + 0.0015 Ω 70 µΩ/Ω + 0.0014 Ω 70 µΩ/Ω + 0.002 Ω 70 µΩ/Ω + 0.002 Ω 70 µΩ/Ω + 0.02 Ω 70 µΩ/Ω + 0.02 Ω 70 µΩ/Ω + 0.2 Ω 86 µΩ/Ω + 0.2 Ω 93 µΩ/Ω + 2 Ω 0.012 % + 2 Ω 0.012 % + 30 Ω 0.047 % + 50 Ω 0.078 % + 2.5 kΩ 0.39 % + 3 kΩ 0.39 % + 0.1 MΩ 1.2 % + 0.5 MΩ Fluke 5502A Resistance – Generate, Fixed Points 3, 4, 8 for Insulation Testers 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 0.012 MΩ 0.12 MΩ 1.2 MΩ 0.012 GΩ 0.24 GΩ 5.8 GΩ Fixed resistors DC Power 3 – Generate Up to 109 µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 109) W (109 to 337) W (337 to 990) W (0.99 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 5.5 W to 16.8 kW (16.8 to 153) kW (153 to 1045) kW 0.019 % 0.013 % 0.010 % 0.0090 % 0.0090 % 0.0090 % 0.010 % 0.010 % 0.032 % 0.032 % 0.052 % 0.080 % 0.19 % 0.20 % 0.21 % Fluke 5502A Fluke 5502A + 50 turn coil
4-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 4 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage 3 – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (0.01 to 10) Hz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 3.9 % + 170 µV 0.12 % + 20 µV 0.078 % + 20 µV 0.12 % + 20 µV 0.16 % + 20 µV 0.27 % + 33 µV 0.78 % + 60 µV 3.9 % + 1.7 mV 0.039 % + 20 µV 0.023 % + 20 µV 0.054 % + 20 µV 0.078 % + 40 µV 0.18 % + 170 µV 0.39 % + 330 µV 3.9 % + 17 mV 0.042 % + 60 µV 0.023 % + 60 µV 0.054 % + 60 µV 0.078 % + 60 µV 0.18 % + 0.2 mV 0.39 % + 0.9 mV 3.9 % + 0.17 V 0.042 % + 0.8 mV 0.023 % + 0.6 mV 0.054 % + 0.6 mV 0.078 % + 0.6 mV 0.18 % + 2 mV 0.039 % + 3 mV 0.062 % + 9 mV 0.070 % + 9 mV 0.093 % + 9 mV 0.19 % + 80 mV 0.039 % + 20 mV 0.062 % + 20 mV 0.070 % + 20 mV Fluke 5502A
See scope document
5-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 5 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Generate (0.029 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.16 % + 0.1 µA 0.12 % + 0.1 µA 0.099 % + 0.1 µA 0.23 % + 0.15 µA 0.62 % + 0.2 µA 1.2 % + 0.4 µA 0.16 % + 0.15 µA 0.099 % + 0.15 µA 0.08 % + 0.15 µA 0.16 % + 0.2 µA 0.39 % + 0.3 µA 0.78 % + 0.6 µA 0.14 % + 2 µA 0.072 % + 2 µA 0.036 % + 2 µA 0.065 % + 2 µA 0.16 % + 3 µA 0.31 % + 4 µA 0.14 % + 20 µA 0.072 % + 20 µA 0.036 % + 20 µA 0.08 % + 50 µA 0.16 % + 0.1 mA 0.31 % + 0.2 mA 0.15 % + 0.1 mA 0.043 % + 0.1 mA 0.05 % + 1 mA 1.9 % + 5 mA 0.15 % + 0.1 mA 0.05 % + 0.1 mA 0.47 % + 1 mA 1.9 % + 5 mA 0.05 % + 2 mA 0.08 % + 2 mA 2.3 % + 2 mA 0.095 % + 5 mA 0.12 % + 5 mA 2.3 % + 5 mA Fluke 5502A
See scope document
6-AC Current; AC Power
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 6 of 14 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current3 – Generate (cont) Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz 100 Hz to 1 kHz (10 to 100) Hz (100 to 400) Hz (10 to 100) Hz (100 to 400) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.19 % + 0.2 µA 0.47 % + 0.5 µA 0.19 % + 0.3 µA 0.47 % + 0.8 µA 0.065 % + 4 µA 0.16 % + 10 µA 0.065 % + 40 µA 0.16 % + 0.1 mA 0.095 % + 0.2 mA 0.23 % + 1 mA 0.095 % + 2 mA 0.78 % + 5 mA 0.29 % + 0.003 A 0.81 % + 0.003 A 0.30 % + 0.025 A 0.83 % + 0.027 A 0.30 % + 0.09 A 1.2 % + 0.1 A Fluke 5502A with LCOMP on Fluke 5502A, 50 turn coil AC Power3 – Generate (45 to 65 Hz, PF=1) Up to 10.9 µW (10.9 to 109) µW (0.109 to 1.09) mW (1.09 to 10.9) mW (10.9 to 109) mW (0.109 to 1.09) W (1.09 to 10.9) W (10.9 to 37) W (37 to 337) W (0.337 to 1.12) kW (1.12 to 3.06) kW (3.06 to 11.2) kW (11.2 to 20.9) kW 0.55 W to 16.8 kW (16.8 to 1045) kW 0.19 % 0.13 % 0.090 % 0.051 % 0.049 % 0.049 % 0.049 % 0.058 % 0.059 % 0.066 % 0.067 % 0.080 % 0.13 % 0.23 % 0.25 % Fluke 5502A Fluke 5502A + 50 turn coil
See scope document
7-Capacitance; Thermocouple Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 7 of 14 Parameter/Equipment Range CMC2, 4 (±) Comments Capacitance3 – Source (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.39 % + 0.01 nF 0.39 % + 0.01 nF 0.39 % + 0.01 nF 0.20 % + 0.01 nF 0.19 % + 0.1 nF 0.19 % + 0.1 nF 0.20 % + 0.3 nF 0.21 % + 1 nF 0.20 % + 3 nF 0.21 % + 10 nF 0.32 % + 30 nF 0.36 % + 0.1 µF 0.35 % + 0.3 µF 0.36 % + 1 µF 0.42 % + 3 µF 0.40 % + 10 µF 0.76 % + 30 µF 0.85 % + 100 µF Fluke 5502A Electrical Calibration of Thermocouple Indicators 3 – Generate & Measure Type E Type J Type K Type N (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.19 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.31 °C 0.31 °C 0.18 °C 0.16 °C 0.15 °C 0.21 °C Fluke 5502A
See scope document
8-Thermocouple Indicators; RTD Indicators; Phase Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 8 of 14 Parameter/Equipment Range CMC2, 4 (±) Comments Electrical Calibration of Thermocouple Indicators 3 – Generate & Measure (cont) Type T (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.49 °C 0.20 °C 0.13 °C 0.12 °C Fluke 5502A Electrical Calibration of RTD Indicators 3 – Generate Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.04 °C 0.04 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.18 °C Fluke 5502A Parameter/Range Frequency CMC2, 4 (±) Comments Electrical Calibration of Phase Indicators 3 – Source Only Up to 90° (10 to 65) Hz (65 to 500)Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to30) kHz 0.18° Phase 1.0° Phase 2.3° Phase 6.9° Phase 12° Phase 17° Phase Fluke 5502A
-
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 9 of 14 Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Voltage 3 – Measure DC High Voltage 3, 4 – Generate & Measure (0 to 100) mV (0.10 to 1.0) V (1.0 to 10) V (10 to 100) V (100 to 1000) V (1 to 100) kV 11 µV/V + 0.3 µV 10 µV/V + 0.3 µV 10 µV/V + 0.5 µV 13 µV/V + 30 µV 14 µV/V + 100 µV 1.2 % Agilent 3458A Phenix KVM 200A Resistance 3 – Measure Up to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 10 MΩ to 1 GΩ (1 to 10) GΩ (10 to 100) GΩ 21 µΩ/Ω + 50 µΩ 18 µΩ/Ω + 0.5 mΩ 17 µΩ/Ω + 0.5 mΩ 16 µΩ/Ω + 5 mΩ 19 µΩ/Ω + 50 mΩ 24 µΩ/Ω + 2 Ω 70 µΩ/Ω + 100 Ω 0.060 % + 1 kΩ 77 μΩ/Ω 0.54 % 0.70 % Agilent 3458A Voltage source & µA range of 3458A DC Current3 – Measure Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A 35 µA/A + 0.8 nA 35 µA/A + 5 nA 40 µA/A + 50 nA 53 µA/A + 0.5 µA 0.018 % + 10 µA 0.12 % 0.14 % 0.32 % 0.39 % Agilent 3458A Empro shunts, DMM
10-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 10 of 14 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.051 % + 3 µV 0.056 % + 1.1 µV 0.083 % + 1.1 µV 0.46 % + 1.1 µV 0.78 % + 1.1 µV 4.7 % + 2 µV 0.013 % + 4 µV 0.016 % + 2 µV 0.027 % + 2 µV 0.12 % + 2 µV 0.23 % + 2 µV 0.41 % + 10 µV 1.2 % + 10 µV 0.011 % + 40 µV 0.016 % + 20 µV 0.024 % + 20 µV 0.041 % + 20 µV 0.11 % + 20 µV 0.36 % + 100 µV 1.2 % + 100 µV 0.029 % + 0.4 mV 0.012 % + 0.2 mV 0.020 % + 0.2 mV 0.037 % + 0.2 mV 0.095 % + 0.2 mV 0.36 % + 1 mV 1.2 % + 1 mV 0.025 % + 4 mV 0.025 % + 2 mV 0.026 % + 2 mV 0.048 % + 2 mV 0.15 % + 2 mV 0.47 % + 10 mV 1.7 % + 10 mV Agilent 3458A
See scope document
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 11 of 14 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage3 – Measure (cont) (100 to 700) V (0.7 to 6) kV (6 to 80) kV (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (DC to 500) Hz 60 Hz 0.048 % + 40 mV 0.048 % + 20 mV 0.070 % + 20 mV 0.14 % + 20 mV 0.35 % + 20 mV 1.4 % 1.6 % Agilent 3458A Fluke 80K-6, DMM Phenix KVM 200A AC Current3 – Measure Up to 100 μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 10) kHz 0.46 % + 0.03 µA 0.18 % + 0.03 µA 0.074 % + 0.03 µA 0.074 % + 0.03 µA 0.46 % + 0.2 µA 0.18 % + 0.2 µA 0.076 % + 0.2 µA 0.047 % + 0.2 µA 0.074 % + 0.2 µA 0.46 % + 2 µA 0.18 % + 2 µA 0.077 % + 2 µA 0.048 % + 2 µA 0.075 % + 2 µA 0.46 % + 20 µA 0.18 % + 20 µA 0.077 % + 20 µA 0.049 % + 20 µA 0.075 % + 20 µA 0.47 % + 200 µA 0.20 % + 200 µA 0.12 % + 200 µA 0.14 % + 200 µA 0.35 % + 200 µA Agilent 3458A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 12 of 14 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current3 – Measure (cont) (1 to 10) A (10 to 50) A (50 to 200) A (200 to 1000) A (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz 0.12 % 0.14 % 0.32 % 0.39 % Empro shunts, DMM III. Mechanical Parameter/Equipment Range CMC2, 6, 8 (±) Comments Torque Devices 5 lbf-in to 2000 lbf-ft 0.94 % AWS torque testers Pressure (Pneumatic) 3 – Measuring Equipment Calibration of Transfer Standards & Pressure Devices Absolute Gauge & Differential (0.3 to 15) psia (15 to 50) psia (0.14 to 300) psi (-15 to 3000) psi 0.0035 psia 0.015 psia 0.0081 % 0.011 % + 0.6R Mensor CPG 2300 RK-300/1100WC Fluke 6270 with PM500 modules Pressure (Hydraulic) 3 – Measuring Equipment (25 to 15 000) psi 0.018 % Ametek Type T deadweight tester
13-Temperature; Frequency; Time Interval
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 13 of 14 IV. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature3 – Measure (-38 to 0.0) °C (0 to 156) °C (156 to 420) °C (420 to 660) °C 0.019 °C 0.023 °C 0.052 °C 0.099 °C PRT & readout Temperature3 – Measuring Equipment (-25 to 0) °C (0 to 156) °C (156 to 250) °C 0.013 °C 0.019 °C 0.051 °C PRT, readout, bath V. Time & Frequency Parameter/Equipment Range CMC 2, 8 (±) Comments Frequency – Measuring Equipment 3, 4 0.1 Hz to 10 MHz 0.01 Hz to 2 MHz 2.4 parts in 10 7 29 μHz/Hz Keysight 3325B ref. to Fluke PM6680 Fluke 5502A Frequency – Measure 3, 4 0.1 Hz to 225 MHz 2.4 parts in 10 7 Fluke PM 6680 Time Interval 3 – Timers & Stop Watches Time Base 7 Totalize Method Up to 24 hours Up to 24 hours 0.043 seconds 0.12 seconds/day NIST SP 960-12 Fluke PM6680 Fluke PM6680, function generator _______________________________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability (CMC) is th e smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal Generate. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement un certainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
-
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1995.07) 05/14/2026 Page 14 of 14 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. Field environmental conditions are limited to 15 °C to 30 °C and <80% relative humidity to 30 °C. 4 Fluke 5502A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 oC. For Resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. For AC Current, CMCs are determined with the LCOMP off and ON. CMCs are also based upon 1-year floor specifications. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 5 Agilent 3458A CMCs are based upon the temperature the standard was calibrated (tcal ± 5 oC) and an auto calibration (ACAL) was performed within the previous 24 hours (± 1 oC of ambient temperature.) CMCs are also based upon 1-year floor specifications. CMCs are expressed as either a specific value that covers the full range or as a combination of a percent or the fraction of the reading/output plus a range specification. 6 In the statement of CMC, percentages are percen tages of reading, unless otherwise indicated, and R is the resolution of the Device Under Test. 7 Applicable when the internal time base (oscillator) of the device under test is/can be measured directly by the frequency counter. 8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy. 10 In the statement of CMC, L is the numerical values of the nominal length measured in inches.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2152 University Drive, Suite #2, Mt. Braddock, PA, 15465, US

39.94285, -79.64449

Open in Maps

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.