Constellation Powerlabs - Madison, PA
680 Waltz Mill Road, Interstate 70, 15663, Madison, PA, United States
Visit website- Scope lines
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 2044.03 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 2 of 12
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage3 – Measure
(0 to 120) mV
100 mV to 1.2 V
(1 to 12) V
(10 to 120) V
(100 to 1050) V
7.1 µV/V + 0.3 µV
6 µV/V + 0.3 µV
6 µV/V + 0.5 µV
8 µV/V + 30 µV
8 µV/V + 120 µV
Long scale multimeter
DC Voltage – Generate
(0 to 220) mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
7.5 µV/V + 0.4 µV
5 µV/V + 0.7 µV
3.5 µV/V + 2.5 µV
3.5 µV/V + 4.4 µV
5 µV/V + 40 µV
6.5 µV/V + 400 µV
Primary multi-function
calibrator
DC Current – Measure
(10 to 120) µA
100 µA to 1.2 mA
(1 to 12) mA
(10 to 120) mA
100 mA to 1.05 A
25 µA/A + 0.8 nA
25 µA/A + 5 nA
25 µA/A + 50 nA
40 µA/A + 500 nA
0.011 % + 10 µA
Long scale multimeter
DC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 15) A
(15 to 20.5) A
40 µA/A + 6 nA
35 µA/A + 7.2 nA
35 µA/A + 41 nA
45 µA/A + 0.7 µA
80 µA/A + 12 µA
0.036 % + 480 µA
0.1 % + 750 µA
0.1 % + 880 µA
Primary multi-function
calibrator
Resistance – Measure
(0 to 12) Ω
(10 to 120) Ω
(100 to 1200) Ω
(1 to 12) kΩ
(10 to 120) kΩ
100 kΩ to 1.2 MΩ
(1 to 12) MΩ
(10 to 120) MΩ
100 MΩ to 1.2 GΩ
18 µΩ/Ω + 50 µΩ
15 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 500 µΩ
13 µΩ/Ω + 5 mΩ
13 µΩ/Ω + 50 mΩ
18 µΩ/Ω + 2 Ω
53 µΩ/Ω + 110 Ω
0.05 % + 1.9 kΩ
0.5 % + 50 kΩ
Long scale multimeter | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 3 of 12
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Resistance – Generate,
Fixed Points
0.0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
55 µΩ
0.011 %
98 µΩ/Ω
23 µΩ/Ω
23 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
8.5 µΩ/Ω
8.5 µΩ/Ω
8.5 µΩ/Ω
8.5 µΩ/Ω
11 µΩ/Ω
11 µΩ/Ω
20 µΩ/Ω
21 µΩ/Ω
40 µΩ/Ω
47 µΩ/Ω
100 µΩ/Ω
Primary multi-function
calibrator
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure
(1 to 12) mV
(12 to 120) mV
120 mV to 1.2 V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
0.03 % + 3 µV
0.02 % + 1.1 µV
0.03 % + 1.1 µV
0.1 % + 1.1 µV
0.5 % + 1.1 µV
4 % + 2 µV
72 µV/V + 4 µV
72 µV/V + 2 µV
0.014 % + 2 µV
0.033 % + 2.5 µV
0.08 % + 2 µV
0.3 % + 10 µV
1 % + 10 µV
1.5 % + 10 µV
72 µV/V + 40 µV
72 µV/V + 20 µV
0.014 % + 20 µV
0.03 % + 20 µV
0.08 % + 20 µV
0.3 % + 100 µV
1 % + 100 µV
1.5 % + 100 µV
Long scale multimeter | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 4 of 12
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure
(cont)
(1.2 to 12) V
(12 to 120) V
(120 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
72 µV/V + 0.4 mV
72 µV/V + 0.2 mV
0.014 % + 0.2 mV
0.03 % + 0.2 mV
0.08 % + 0.2 mV
0.3 % + 1 mV
1 % + 1 mV
1.5 % + 1 mV
0.02 % + 4 mV
0.02 % + 2 mV
0.02 % + 2 mV
0.04 % + 2 mV
0.12 % + 2 mV
0.4 % + 10 mV
1.5 % + 10 mV
0.04 % + 40 mV
0.04 % + 20 mV
0.06 % + 20 mV
0.12 % + 20 mV
0.3 % + 20 mV
Long scale multimeter
AC Voltage – Generate
(0.22 to 2.2) mV
(2.2 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.025 % + 4 µV
91 µV/V + 4 µV
90 µV/V + 4 µV
0.02 % + 4 µV
0.053 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.27 % + 20 µV
0.028 % + 4 µV
94 µV/V + 4 µV
84 µV/V + 4 µV
0.02 % + 4 µV
0.05 % + 5 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.27 % + 20 µV
Primary multi-function
calibrator with
precision amplifier | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 5 of 12
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(22 to 220) V
(220 to 250) V
(220 to 1100) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.024 % + 12 µV
91 µV/V + 7 µV
81 µV/V + 7 µV
0.02 % + 8 µV
0.046 % + 17 µV
0.09 % + 20 µV
0.14 % + 25 µV
0.27 % + 45 µV
0.024 % + 44 µV
90 µV/V + 18 µV
48 µV/V + 8 µV
80 µV/V + 12 µV
0.011 % + 35 µV
0.042 % + 80 µV
0.1 % + 200 µV
0.17 % + 300 µV
0.024 % + 420 µV
90 µV/V + 150 µV
45 µV/V + 80 µV
75 µV/V + 140 µV
0.01 % + 350 µV
0.028 % + 600 µV
0.1 % + 2000 µV
0.15 % + 3200 µV
0.024 % + 4.1 mV
91 µV/V + 1.5 mV
53 µV/V + 0.8 mV
82 µV/V + 1.5 mV
0.015 % + 3.4 mV
0.09 % + 16 mV
0.44 % + 40 mV
0.8 % + 80 mV
0.03 % + 16 mV
71 µV/V + 3.7 mV
90 µV/V + 4.5 mV
0.017 % + 6 mV
0.06 % + 11 mV
0.06 % + 11 mV
0.23 % + 45 mV
Primary multi-function
calibrator with
precision amplifier
Primary multi-function
calibrator
Primary multi-function
calibrator with
precision amplifier | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 6 of 12
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Measure
(12 to 120) µA
120 µA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
(0.12 to 1) A
(0.04 to 0.1999) A
(0.2 to 0.9999) A
(1 to 20) A
(20 to 5000) A
(5 to 17) kA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(20 to 500) Hz
(20 to 500) Hz
(20 to 500) Hz
60 Hz
60 Hz
0.4 % + 30 nA
0.15 % + 30 nA
0.06 % + 30 nA
0.06 % + 30 nA
0.4 % + 200 nA
0.15 % + 200 nA
0.06 % + 200 nA
0.03 % + 200 nA
0.4 % + 2 µA
0.15 % + 2 µA
0.06 % + 2 µA
0.03 % + 2 µA
0.4 % + 20 µA
0.15 % + 20 µA
0.06 % + 20 µA
0.03 % + 20 µA
0.4 % + 200 µA
0.16 % + 200 µA
0.08 % + 200 µA
0.1 % + 200 µA
0.15 %
0.081 %
0.051 %
0.08 %
0.38 %
Long scale multimeter
Precision current
monitor
Primary current
transformers &
precision current
monitor | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 7 of 12
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Generate
(10 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.025 % + 16 nA
0.016 % + 10 nA
0.012 % + 8 nA
0.028 % + 12 nA
0.11 % + 65 nA
0.025 % + 40 nA
0.016 % + 35 nA
0.012 % + 35 nA
0.02 % + 110 nA
0.11 % + 650 nA
0.025 % + 400 nA
0.016 % + 350 nA
0.012 % + 350 nA
0.02 % + 550 nA
0.11 % + 5000 nA
0.025 % + 4 µA
0.016 % + 3.5 µA
0.012 % + 2.5 µA
0.02 % + 3.5 µA
0.11 % + 10 µA
0.026 % + 39 µA
0.045 % + 80 µA
0.7 % + 160 µA
0.046 % + 170 µA
0.095 % + 380 µA
0.36 % + 750 µA
0.12 % + 5000 µA
0.15 % + 5000 µA
3 % + 5000 µA
Precision multi-function
calibrator
Precision multi-function
calibrator with precision
amplifier
Precision multi-function
calibrator
Phase – Generate3
(0 to 90)°
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.1°
0.25°
0.5°
2.5°
5°
10°
Precision multi-function
calibrator with phase
generation | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 8 of 12
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Electrical Calibration of
Thermocouple
Devices3 –
Type E
Type J
Type K
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -30) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.5 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.4 °C
0.57 °C
0.35 °C
0.33 °C
0.4 °C
0.47 °C
0.36 °C
0.37 °C
0.46 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Precision multi-function
calibrator with
temperature generation | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 9 of 12
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 9 (±)
Comments
Gage Pressure
(0 to 1000) psig
(150 to 830) psig
(830 to 1080) psig
(1080 to 1330) psig
(1330 to 1500) psig
(1500 to 8650) psig
(8650 to 10 900) psig
(10 900 to 13 150) psig
(13 150 to 15 000) psig
(10 000 to 40 000) psig
0.27 psig
0.026 %
0.027 %
0.028 %
0.029 %
0.031 %
0.032 %
0.033 %
0.034 %
11 psig
Precision pressure
calibrator
Primary deadweight tester
Precision pressure
calibrator
Torque Transducers
(5 to 250) lbf·ft
(5 to 1000) lbf·ft
0.07 %
0.086 %
Class F weights mounted
on a precision torque arm
Torque Wrenches3
(5 to 1000) lbf·ft
0.7 %
Precision torque
transducer system
Mass – Measure, Fixed
Points
1 mg
2 mg
3 mg
5 mg
10 mg
20 mg
30 mg
50 mg
100 mg
200 mg
300 mg
500 mg
1 g
2 g
3 g
5 g
10 g
20 g
30 g
50 g
100 g
200 g
300 g
500 g
1000 g
2000 g
0.0033 mg
0.0033 mg
0.0033 mg
0.0033 mg
0.0069 mg
0.0069 mg
0.0069 mg
0.0069 mg
0.0088 mg
0.0088 mg
0.0088 mg
0.0089 mg
0.0081 mg
0.0089 mg
0.0085 mg
0.011 mg
0.024 mg
0.025 mg
0.024 mg
0.032 mg
0.077 mg
0.11 mg
0.11 mg
0.42 mg
0.46 mg
0.94 mg
Double substitution
method comparison to
Ultra Class standard
weights using a precision
balance | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 10 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Scales & Balances3
(2 to 500) mg
500 mg to 5 g
(5 to 20) g
(20 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 500) g
(0.5 to 1) kg
(1 to 2) kg
(2 to 3) kg
(3 to 5) kg
(5 to 10) kg
(10 to 32) kg
0.0013 mg
0.007 mg
0.03 mg
0.064 mg
0.13 mg
0.24 mg
0.61 mg
1.5 mg
2.5 mg
10 mg
0.15 g
0.2 g
0.36 g
Reference weights up to
32 kg
Force3 – Compression &
Tension – Measure
(40 to 1000) lbf
(1001 to 2000) lbf
(2001 to 5000) lbf
(5001 to 10 000) lbf
(10 001 to 25 000) lbf
(25 001 to 50 000) lbf
(50 001 to 100 000) lbf
0.52 lbf
1.1 lbf
1.4 lbf
2.6 lbf
6.3 lbf
13 lbf
25 lbf
Precision Load Cells &
system
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Temperature – Measure
(-190 to 660) °C
(200 to 1000) °C
0.044 °C
0.9 °C
Precision thermometer
with reference SPRT,
precision temperature
baths & furnace
Precision temperature
baths & furnace
Temperature –
Measuring Equipment,
Thermocouples7
Type E
Type J
Type K
Type N
Type T
Type J
Type K
(20 to 660) °C
(50 to 660) °C
(50 to 660) °C
(50 to 660) °C
(50 to 350) °C
(200 to 700) °C
(200 to 700) °C
0.6 °C
0.6 °C
0.61 °C
0.6 °C
0.6 °C
1.1 °C
1.1 °C
Blackstack, SPRT,
precision temperature
baths & furnace
Type S thermocouple,
indicator, baths&furnaces | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 11 of 12
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Infrared Temperature -
Measuring Equipment 3
(-15 to 120) °C
(120 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.67 °C
1 °C
1.6 °C
2.2 °C
Primary infrared
temperature blackbody
sources
ε = 0.9 to 1.0
λ = (8 to 14) µm
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measuring
Equipment3
0.01 Hz to 2 MHz
2.5 µHz/Hz + 5 μHz
Precision multi-function
calibrator
Frequency – Measure
(1 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 100) kHz
100 kHz to 1 MHz
(1 to 10) MHz
(10 to 100) MHz
(100 to 225) MHz
225 MHz to 1 GHz
(1 to 3) GHz
6.6 µHz
20 µHz
130 µHz
1.2 mHz
9.3 mHz
9.3 mHz
2.4 mHz
5.1 mHz
23 mHz
65 mHz
Precision frequency
counter referenced to
the GPS
____________________________________________
1 This laboratory offers commercial and field calibration service where noted.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2044.03) 09/08/2025 Page 12 of 12
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
R is the resolution of the device under test, and % is the percentage of the reading.
5 Uncertainties for metric micrometers and calipers up to 900 mm are available upon request.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 The CMC associated with Temperature – Measuring Equipment, Thermocouples does not include
inhomogeneity of the test thermocouple.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 13 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- JM Test SystemsMt. Braddock, PA · ~34 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ohm-LabsPittsburgh, PA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Process InstrumentsPittsburgh, PA · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsAliquippa, PA · ~64 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hapeman ElectronicsStoneboro, PA · ~127 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.