Midwest Metrology
341 Smith Drive, 45315, Clayton, OH, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 1577.01 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 2 of 15
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Generate3
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
8 μV/V + 0.6 μV
7 μV/V + 1.0 μV
6.8 μV/V + 5.7 μV
7 μV/V + 7 μV
9.1 μV/V + 130 μV
8.4 μV/V + 1.2 mV
Fluke 5700A
DC Voltage – Measure3
(1 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 60) kV
5.4 μV/V + 0.4 μV
4.4 μV/V + 0.5 μV
4.5 μV/V + 1.6 μV
3.7 μV/V + 34 μV
15 μV/V + 42 μV
3.0 mV/V + 6.8 μV
Agilent 3458A opt
002
Ross VD-60 w/ DMM
DC Current – Measure3
(1 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 20) A
22 μA/A + 800 pA
20 μA/A + 5.3 nA
21 μA/A + 50 nA
36 μA/A + 490 nA
110 μA/A + 10 μA
110 μA/A + 13 μA
Agilent 3458A opt
002
Agilent 3458A, Fluke
Y5020A
DC Current – Generate3
Clamp Meters
(0 to 220) μA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(10 to 1000) A
50 μA/A + 8 nA
47 μA/A + 15 nA
48 μA/A + 0.13 μA
60 μA/A + 0.89 μA
79 μA/A + 27 μA
360 μA + 480 μA
3.5 mA/A + 13 mA
Fluke 5700A
Fluke 5700A/5725A
Fluke 5500A w/ coil
Resistance – Measure3
(0.01 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
9 μΩ/Ω + 170 μΩ
14 μΩ/Ω + 490 μΩ
12 μΩ/Ω + 550 μΩ
12 μΩ/Ω + 4.7 mΩ
13 μΩ/Ω + 45 mΩ
18 μΩ/Ω + 2 Ω
53 μΩ/Ω + 110 Ω
0.49 mΩ/Ω + 2.5 kΩ
5 mΩ/Ω + 14 kΩ
Agilent 3458A opt
002 | to 1000 A |
| 3 | Ohms Law Method | - | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 4 of 15
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance – Generate3
Fixed Points –
0.001 µF
0.01 µF
0.1 µF
10 pF to 1 µF
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.099 99) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
@ 1 kHz
@ 1 kHz
(0.01 to 10) kHz
(0.01 to 10) kHz
(0.01 to 3) kHz
(0.01 to 1) kHz
(0.01 to 1) kHz
(0.01 to 1) kHz
(0.01 to 1) kHz
(0.01 to 600) Hz
(0.01 to 300) Hz
(0.01 to 150) Hz
(0.01 to 120) Hz
(0.01 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.53 pF
5.2 pF
51 pF
0.053 % + 0.5 pF
0.49 % + 10 pF
0.49 % + 10 pF
0.5 % + 10 pF
0.25 % + 10 pF
0.25 % + 100 pF
0.26 % + 99 pF
0.26 % + 290 pF
0.26 % + 1 nF
0.26 % + 3 nF
0.26 % + 10 nF
0.41 % + 29 nF
0.47 % + 96 nF
0.46 % + 300 nF
0.45 % + 1.1 μF
0.45 % + 3 μF
0.44 % + 11 μF
0.75 % + 30 μF
1.1 % + 100 μF
GR 1409 standard
capacitors
GR 1413-decade
capacitor
Fluke 5500A
Capacitance – Measure3
(1 to 10) pF
(10 to 100) pF
100 pF to 25 μF
(25 to 100) μF
(100 to 1000) μF
1 pF to 1000 nF
12 Hz to 100 kHz
1 kHz
0.026 % + 0.6 fF
0.029 % + 0.3 fF
0.023 % + 3 fF
0.024 %
0.035 % + 11 nF
2.7 µF/F
GR 1689M
CMC valid at 1 kHz
only. Lab uses IET
calculator for other
frequencies
AH2500A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 5 of 15
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(0.22 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.55 mV/V + 4.5 μV
0.21 mV/V + 4.5 μV
0.11 mV/V + 4.5 μV
0.37 mV/V + 4.5 μV
0.85 mV/V + 7 μV
1.1 mV/V + 13 μV
1.7 mV/V + 25 μV
3.4 mV/V + 25 μV
0.55 mV/V + 5 μV
0.21 mV/V + 5 μV
0.11 mV/V + 5 μV
0.37 mV/V + 5 μV
0.85 mV/V + 7 μV
1.1 mV/V + 12 μV
1.7 mV/V + 25 μV
3.4 mV/V + 25 μV
0.44 mV/V + 44 μV
0.21 mV/V + 8.5 μV
0.11 mV/V + 8 μV
0.32 mV/V + 8 μV
0.85 mV/V + 25 μV
1.1 mV/V + 25 μV
1.7 mV/V + 35 μV
3.4 mV/V + 80 μV
450 μV/V + 340 μV
160 μV/V + 29 μV
75 μV/V + 6.2 μV
120 μV/V + 16 μV
250 μV/V + 70 μV
420 μV/V + 130 μV
1.1 mV/V + 350 μV
2.2 mV/V + 850 μV
0.37 mV/V + 4.3 mV
160 μV/V + 310 μV
75 μV/V + 62 μV
120 μV + 160 μV
250 μV/V + 350 μV
0.5 mV/V + 1.5 mV
1.3 mV/V + 4.3 mV
2.7 mV/V + 8.5 mV
Fluke
5700A/5725A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 6 of 15
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) V
(220 to 250) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.49 mV/V + 9.9 mV
0.16 mV/V + 2.5 mV
80 μV/V + 810 μV
0.22 mV/V + 3.5 mV
0.5 mV/V + 8 mV
1.5 mV/V + 90 mV
4.7 mV/V + 90 mV
12 mV/V + 190 mV
40 μV/V + 17 mV
80 μV/V + 3.9 mV
90 μV/V + 4.4 mV
0.17 mV/V + 6.1 mV
0.6 mV/V + 11 mV
0.6 mV/V + 11 mV
2.2 mV/V + 180 mV
Fluke 5700A
Fluke
5700A/5725A
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
0.16 mV/V + 2 μV
0.24 mV/V + 2 μV
0.94 mV/V + 2 μV
5 mV/V + 1.5 μV
40 mV/V + 2 μV
72 μV/V + 2 μV
0.14 mV/V + 2 μV
0.3 mV/V + 2 μV
0.8 mV/V + 2 μV
3 mV/V + 10 μV
59 μV/V + 39 μV
130 μV/V + 37 μV
0.29 mV/V + 33 μV
0.79 mV/V + 27 μV
3 mV/V + 0.1 mV
10 mV/V + 0.1 mV
40 mV/V + 0.7 mV
41 mV/V + 0.17 μV
150 mV/V + 1 mV
Agilent 3458A opt
002/H01 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 7 of 15
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(cont)
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 42) kV
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 4) MHz
(4 to 8) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
60 Hz
73 μV/V + 0.2 mV
140 μV/V + 0.2 mV
0.2 mV/V + 0.3 mV
0.8 mV/V + 0.2 mV
3 mV/V + 1 mV
10 mV/V + 1 mV
40 mV/V + 7 mV
40 mV/V + 8 mV
0.2 mV/V + 2 mV
0.2 mV/V + 2 mV
0.42 mV/V + 3 mV
1.2 mV/V + 2 mV
4 mV/V + 10 mV
15 mV/V + 10 mV
0.4 mV/V + 23 mV
0.6 mV/V + 20 mV
1.2 mV/V + 20 mV
5.0 mV/V + 1 V
Agilent 3458A opt
002/H01
Ross VD-60 w/
DMM
AC Current – Measure3
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
1.5 mA/A + 30 nA
0.6 mA/A + 30 nA
0.6 mA/A + 30 nA
1.5 mA/A + 0.21 μA
0.6 mA/A + 0.21 μA
0.29 mA/A + 0.21 μA
0.59 mA/A + 0.21 μA
4.8 mA/A + 0.33 μA
5.5 mA/A + 1.5 μA
1.5 mA/A + 2.1 μA
0.59 mA/A + 2.1 μA
0.29 mA/A + 2.1 μA
0.59 mA/A + 2.1 μA
4 mA/A + 4 μA
5.5 mA/A + 15 μA
Agilent 3458A opt
002 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 8 of 15
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure3
(cont)
(10 to 100) mA
(0.1 to 1) A
(0 to 20) A
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(45 to 100) Hz
(0.1 to 1) kHz
1.5 mA/A + 21 μA
0.59 mA/A + 21 μA
0.29 mA/A + 21 μA
0.59 mA/A + 21 μA
4 mA/A + 40 μA
5.5 mA/A + 150 μA
1.6 mA/A + 0.2 mA
0.81 mA/A + 0.2 mA
1 mA/A + 0.2 mA
3 mA/A + 0.2 mA
10 mA/A + 0.4 mA
0.23 mA/A + 1.9 mA
0.35 mA/A + 1.8 mA
Agilent 3458A opt
002/H01
Agilent 3458A, Fluke
Y5020
AC Current – Generate3
(10 to 220) μA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.7 mA/A + 25 nA
0.35 mA/A + 20 nA
0.14 mA/A + 16 nA
0.6 mA/A + 40 nA
1.6 mA/A + 80 nA
0.70 mA/A + 41 nA
0.35 mA/A + 35 nA
0.14 m/A + 35 nA
0.6 mA/A + 0.4 μA
1.6 mA/A + 0.8 μA
0.7 mA/A + 0.43 μA
0.35 mA/A + 0.35 μA
0.14 mA/A + 0.35 μA
0.8 mA/A + 2 μA
1.6 mA/A + 8 μA
0.7 mA/A + 4.3 μA
0.35 mA/A + 3.5 μA
0.14 mA/A + 3.5 μA
0.6 mA/A + 40 μA
1.6 mA/A + 80 μA
Fluke 5700A, Fluke
5522A
Fluke 5700A/5725A,
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 9 of 15
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
(0.22 to 2.2) A
(2.2 to 11) A
(20 to 500) A
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(100 to 440) Hz
0.26 mA/A + 39 μA
0.75 mA/A + 80 μA
8.5 mA/A + 0.16 mA
0.46 mA/A + 0.17 mA
0.95 mA/A + 0.38 mA
3.6 mA/A + 0.75 mA
1.6 mA/A + 0.2 A
10 mA/A + 0.11 A
Fluke 5700A
Fluke 5700A/5725A
Fluke 5522A w/ coil
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators &
Indicating Systems3 –
Type E
Type J
Type K
Type N
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
0.5 °C
0.17 °C
0.15 °C
0.17 °C
0.21 °C
0.27 °C
0.17 °C
0.15 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.17 °C
0.26 °C
0.4 °C
0.4 °C
0.22 °C
0.19 °C
0.18 °C
0.27 °C
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 10 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators &
Indicating Systems3 – (cont)
Type R
Type S
Type T
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.57 °C
0.35 °C
0.33 °C
0.4 °C
0.47 °C
0.36 °C
0.37 °C
0.46 °C
0.63 °C
0.24 °C
0.17 °C
0.15 °C
Fluke 5522A
Electrical Calibration of RTD
Indicators & Indicating
Systems
3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
0.23 °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
0.25 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
0.23 °C
Fluke 5522A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 11 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of RTD
Indicators & Indicating Systems3
– (cont)
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 385, 120 Ω
(Ni 120)
Cu 427, 10 Ω
(-200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 600) °C
(600 to 630) °C
(-80 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.04 °C
0.05 °C
0.12 °C
0.13 °C
0.14 °C
0.16 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.11 °C
0.03 °C
0.04 °C
0.05 °C
0.05 °C
0.07 °C
0.23 °C
0.08 °C
0.14 °C
0.3 °C
Fluke 5522A
Parameter/Range
Frequency
CMC2 (±)
Comments
Oscilloscope3 –
Level Sine Wave 5 mV to 5.5
V(p-p)
Leveled Sine Flatness
5 mV to 5.5 V(p-p)
Relative to 50 kHz
Reference
50 kHz reference
(0.5 to 100) MHz
(0.1 to 0.3) GHz
(0.3 to 0.6) GHz
16 mV/V + 230 μV
12 mV/V + 200 μV
18 mV/V + 220 μV
32 mV/V + 360 μV
Fluke 5500A
w/ SC600 option | ||
| 12 | ASTM Class 1; NIST Class F | - | See scope document |
| 13 | ASTM Class 6 | - | See scope document |
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 14 of 15
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Relative Humidity3 –
Measuring Equipment
Measure
(10 to 95) % RH
(10 to 90) % RH
0.002 % + 0.48 % RH
1.1 % RH
Thunder Scientific
1200 humidity
generator
Standard RH
probe
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measuring
Equipment
10 MHz
1 nHz/Hz
ArgoSystems
AS210 rubidium
Frequency – Measure3
0.1 Hz to 3 GHz
1 nHz/Hz
Agilent 53132A
referenced to
GPS/rubidium
source
Stopwatches – Digital3
32.768 kHz
0.063 Hz
HP 5335A w/
wave analyzer
____________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | 10 to 95 % RH |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1577.01) 2/26/2025 Page 15 of 15
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Instrument Calibration SolutionsClayton, OH · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Testing Services,Miamisburg, OH · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DaytonSpringboro, OH · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western Environmental a Division of Controlled Environment Systems (CES)Springboro, OH · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Cleveland, OHOakwood Village, OH · ~51 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.