Quality Control Sales and Services
5803 West 73rd Street, 46278-1743, Indianapolis, IN, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1498.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 4 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1498.01) 7/23/2024 Page 2 of 4
Parameter/Equipment
Range CMC2, 4 (±) Comments
Thread Wires
(80 to 2) TPI
14 µin
Horizontal ULM
Indicators –
Standard and Dial Bore
Gages3
Electronic Indicators
Up to 4 in
Up to 3 in
(41 + 0.6R) µin
(14 + 0.6R) µin
Indicator calibrator
Horizontal ULM
Calipers3
Up to 80 in
(490 + 20L) µin
Gage blocks
Micrometers –
Depth3
Inside
3
Outside
3
Heads3
Vee
Up to 12 in
(1.5 to 40) in
Up to 36 in
Up to 2 in
Up to 1.5 in
220 µin
(240 + 10L) µin
(80 + 17L) µin
(80 + 17L) µin
(80 + 17L) µin
Gage blocks
Pins and balls
Height Masters and
Caliper Checkers
Up to 40 in
(45 + 2.3L) µin
Gage blocks
Height Gages3
Up to 40 in
460 µin
Gage blocks
Granite Surface Plate3 –
Flatness
Repeat Reading
Up to 96 in x 120 in
Up to 0.0005 in
(13 + 0.4Di) µin +
Closure Error
19 µin
HeNe laser
Repeat-o-meter
Optical Flats, Measuring
Anvils
Up to 6 in
2.6 µin
Monochromatic light and
optical flat comparison | 2 to 80 TPI |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1498.01) 7/23/2024 Page 3 of 4
Parameter/Equipment
Range CMC2, 4 (±) Comments
Cylindrical Squares, Steel
and Granite Squares –
Fixed Point
18 in
(58 + 1.4L) µin
Master square
comparison
Sine Bars –
Parallelism
Flatness
Dowel Distance
Up to 21 in
93 µin
92 µin
(64 + 3.8L) µin
Gage blocks
Electronic amplifier
High Resolution
Micrometer Heads
Up to 2 in
16 µin
Horizontal ULM
Cylindrical Gages –
Outside Diameter
Outside Diameter
Inside Diameter (Plain
Ring Gages)
Up to 20 in
Up to 4 in
(0.04 to 1.2) in
(> 1.2 to 9) in
(20 + 1.4L) µin
33 µin
36 µin
(31 + 4.7D) µin
Horizontal ULM,
mechanical comparison
THV calibrator
Horizontal ULM,
mechanical comparison
Feeler/Thickness Gages
Up to 4 in
Up to 20 in
33 µin
(20 + 1.4L) µin
THV calibrator
Horizontal ULM,
mechanical comparison
Sphere Diameter
Up to 3 in
(20 + 1.4L) µin
Horizontal ULM,
mechanical comparison
Length Standards
Up to 4 in
Up to 20 in
Up to 50 in
33 µin
(20 + 1.4L) µin
(57 + 4.2L) µin
THV calibrator
Horizontal ULM,
mechanical comparison
Surface plate and gage
blocks | to 50 in |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1498.01) 7/23/2024 Page 4 of 4
Parameter/Equipment
Range CMC2, 4 (±) Comments
Parallels
Up to 6 in
(57 + 4.2L) µin
Surface plate and gage
blocks
Riser Blocks
Up to 50 in
(57 + 4.2L) µin
Surface plate and gage
blocks
Optical Comparators3 –
XY Linears
Magnification
Up to 6 in
5x to 100x
180 µin
870 µin
Glass masters
Glass masters and gage
balls
_____________________________________________
1 This laboratory offers commercial and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the nominal length of the device in inches; D is the diameter of the device
in inches; Di is the diagonal length of the device in inches; R is resolution of the device in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | to 6 in |
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Magnetic InstrumentationIndianapolis, IN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Endress+HauserGreenwood, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Radian ResearchLafayette, IN · ~96 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsClayton, OH · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Midwest MetrologyClayton, OH · ~154 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.