Registers refreshed 2026-11-20.See refresh dates
United States

Quality Control Sales and Services

5803 West 73rd Street, 46278-1743, Indianapolis, IN, United States

Visit website
A2LA 1498.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 1498.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 4 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1498.01) 7/23/2024 Page 2 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Thread Wires (80 to 2) TPI 14 µin Horizontal ULM Indicators – Standard and Dial Bore Gages3 Electronic Indicators Up to 4 in Up to 3 in (41 + 0.6R) µin (14 + 0.6R) µin Indicator calibrator Horizontal ULM Calipers3 Up to 80 in (490 + 20L) µin Gage blocks Micrometers – Depth3 Inside 3 Outside 3 Heads3 Vee Up to 12 in (1.5 to 40) in Up to 36 in Up to 2 in Up to 1.5 in 220 µin (240 + 10L) µin (80 + 17L) µin (80 + 17L) µin (80 + 17L) µin Gage blocks Pins and balls Height Masters and Caliper Checkers Up to 40 in (45 + 2.3L) µin Gage blocks Height Gages3 Up to 40 in 460 µin Gage blocks Granite Surface Plate3 – Flatness Repeat Reading Up to 96 in x 120 in Up to 0.0005 in (13 + 0.4Di) µin + Closure Error 19 µin HeNe laser Repeat-o-meter Optical Flats, Measuring Anvils Up to 6 in 2.6 µin Monochromatic light and optical flat comparison
2 to 80 TPI
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1498.01) 7/23/2024 Page 3 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Cylindrical Squares, Steel and Granite Squares – Fixed Point 18 in (58 + 1.4L) µin Master square comparison Sine Bars – Parallelism Flatness Dowel Distance Up to 21 in 93 µin 92 µin (64 + 3.8L) µin Gage blocks Electronic amplifier High Resolution Micrometer Heads Up to 2 in 16 µin Horizontal ULM Cylindrical Gages – Outside Diameter Outside Diameter Inside Diameter (Plain Ring Gages) Up to 20 in Up to 4 in (0.04 to 1.2) in (> 1.2 to 9) in (20 + 1.4L) µin 33 µin 36 µin (31 + 4.7D) µin Horizontal ULM, mechanical comparison THV calibrator Horizontal ULM, mechanical comparison Feeler/Thickness Gages Up to 4 in Up to 20 in 33 µin (20 + 1.4L) µin THV calibrator Horizontal ULM, mechanical comparison Sphere Diameter Up to 3 in (20 + 1.4L) µin Horizontal ULM, mechanical comparison Length Standards Up to 4 in Up to 20 in Up to 50 in 33 µin (20 + 1.4L) µin (57 + 4.2L) µin THV calibrator Horizontal ULM, mechanical comparison Surface plate and gage blocks
to 50 in
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1498.01) 7/23/2024 Page 4 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Parallels Up to 6 in (57 + 4.2L) µin Surface plate and gage blocks Riser Blocks Up to 50 in (57 + 4.2L) µin Surface plate and gage blocks Optical Comparators3 – XY Linears Magnification Up to 6 in 5x to 100x 180 µin 870 µin Glass masters Glass masters and gage balls _____________________________________________ 1 This laboratory offers commercial and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the nominal length of the device in inches; D is the diameter of the device in inches; Di is the diagonal length of the device in inches; R is resolution of the device in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
to 6 in
5ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

5803 West 73rd Street, Indianapolis, IN, 46278-1743, US

39.76833, -86.15835

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.