Endress+Hauser
2355 Endress Place, 46143, Greenwood, IN, United States
Visit website- Accredited standards
- 1
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ISO 4185Measurement of liquid flow in closed conduits - Weighing method
ASME/ANSI MFC-M9-1988; ISO 4185
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active3041.02
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 3041.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 0 to 3 A |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3041.02) Revised 10/02/2025 Page 2 of 7
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Thermocouple Output
(Electrical Simulation of
Thermocouples) 3
Type E
Type J
Type K
Type T
(-10 to 75) mV
(-250 to 1000) °C
(-210 to 1200) °C
(-200 to 1372) °C
(-250 to 400) °C
0.0038 % + 3 μV
0.6 °C
0.3 °C
0.5 °C
0.7 °C
Martel 3001/
Fluke 7526A
Thermocouple Input3
(-10 to 75) mV
0.0038 % + 3 μV
Martel 3001/
Fluke 7526A
Resistance3 – Measure
(5 to 400) Ω
5 Ω to 4 kΩ
0.0041 % of rdg + 0.004 Ω
0.0041 % of rdg + 0.04 Ω
Martel 3001/
Fluke 7526A
Resistance3 – Generate
(Electrical Simulation of
RTD)
Pt 385, 100 Ω
(5 to 400) Ω
5 Ω to 4 kΩ
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.026 Ω
0.40 Ω
0.06 °C
0.07 °C
0.07 °C
0.07 °C
0.07 °C
0.08 °C
0.08 °C
Martel 3001/
Fluke 7526A | ||
| 3 | ASME/ANSI MFC-M9-1988; ISO 4185 | Liquids | See scope document |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3041.02) Revised 10/02/2025 Page 4 of 7
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Flow Rate – Liquids
Flow rig FCP2.15US
Mass
Volumetric
(100 to 15,000)
g/min
(100 to 15,000)
ml/min
0.048 % of rdg
0.049 % of rdg
Gravimetric flow rig
III. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pressure – Gauges &
Transducers
Gauge, Pneumatic
Differential
Gauge, Pneumatic/
Hydraulic
Pressure
3 – Gauges &
Transducers
Differential
(1.6 to 315) psia
(5 to 1515) psia
(0 to 0.75) psig
(0 to 1.5) psig
(0 to 7.5) psig
(0 to 15) psig
(0 to 165) psia
(0 to 765) psia
(0 to 2.5) psig
(0 to 5.0) psig
(0 to 50.0) psig
(-0.75 to 0.75) psid
(-1.5 to 1.5) psid
(-7.5 to 7.5) psid
(-15 to 15) psid
(600 to 10 000) psig
(0 to 1) inH
2O
(0 to 10) inH2O
0.013 % FS
0.013 % FS
0.031 % FS
0.031 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.031 % FS
0.031 % FS
0.013 % FS
0.013 % FS
0.013 % FS
0.36 % FS
0.32 % FS
0.30 % FS
Mensor CPC6000
Mensor CPC6050
Mensor CPC6000
Mensor CPG2500
Fluke 74x/75x series:
w/ 7x0P00
w/ 700P01
w/ 750P01 | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3041.02) Revised 10/02/2025 Page 5 of 7
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pressure3 – Gauges &
Transducers cont.
Differential cont.
Gauge
Gauge, Hydraulic
Absolute
(0 to 5) psid
(0 to 15) psid
(-1 to 1) psig
(-15 to 100) psig
(-15 to 300) psig
(0 to 30) psig
(0 to 100) psig
(0 to 500) psig
(0 to 1000) psig
(0 to 5000) psig
(0 to 10000) psig
(0.75 to 100) psia
0.11 % FS
0.054 % FS
0.059 % FS
0.050 % FS
0.050 % FS
0.15 % FS
0.058 % FS
0.050 % FS
0.050 % FS
0.058 % FS
0.050 % FS
0.050 % FS
0.058 % FS
0.050 % FS
0.058 % FS
0.086 % FS
0.050 % FS
0.050 % FS
0.075 % FS
0.050 % FS
Fluke 74x/75x series:
w/ 700P03
w/ 750P03
w/ 700P23
w/ 750P23
w/ 750P04
w/ 750PD2
w/ 700PD6
w/ 750PD6
w/ 750PD27
w/ 700P05
w/ 750P05
w/ 750P06
w/ 700P07
w/ 750P07
w/ 700P08
w/ 700P30
w/ 750P30
w/ 750P31
w/ 700PA6
w/ 750PA6 | 0 to 10000 psig |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3041.02) Revised 10/02/2025 Page 6 of 7
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Gauge, Pneumatic
(1.7 to 51) psia
(-13 to 35) psig
(1.7 to 595) psia
(-13 to 600) psig
(1.2 to 45) psia
(-13.5 to 35) psig
(1.2 to 515) psia
(-13.5 to 500) psig
(1.2 to 615) psia
(-13.5 to 600) psig
(1.2 to 1015) psia
(-13.5 to 1000) psig
0.029 % FS
0.023 % FS
0.029 % FS
0.023 % FS
0.031 % FS
0.022 % FS
0.031 % FS
0.022 % FS
0.022 % FS
0.022 % FS
0.022 % FS
0.022 % FS
Additel ADT761-HA
Additel ADT761A-500-
CP35
Additel ADT761A-
1K-CP600
IV. Thermodynamic
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature – Measuring
Equipment
Temperature
3 – Measuring
Equipment
(-30 to 200) °C
(35 to 200) °C
(-10 to 125) °C
(-5 to 125) °C
(35 to 200) °C
(50 to 100) °C
(100 to 375) °C
0.030 °C
0.053 °C
0.07 °C
0.087 °C
0.097 °C
0.30 °C
0.60 °C
Liquid bath w/SPRT &
thermometer
Dry block w/SPRT &
thermometer
Liquid bath w/SPRT &
thermometer
Dry block w/SPRT &
thermometer | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3041.02) Revised 10/02/2025 Page 7 of 7
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency – Measure
1 Hz to 110 kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 300 kHz
0.0013 % of rdg
0.081 % of rdg
0.047 % of rdg
0.023 % of rdg
0.0082 % of rdg
Philips PM6671
Agilent 34410A
Frequency – Source
10 Hz to 10 MHz
0.0026 % of rdg + 3 pHz
Agilent 33210A
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 It is common practice for the laboratory to perform calibration of electrical parameters associated with
one of the above calibration methods as it is related to the process instrument. In many cases, the
calibration of electrical parameters (i.e. voltage, current, frequency, etc.) is required to determine the
value of a flow, pressure, or temperature variable in a system where a transmitter or remote indicating
device is one component in the whole system being calibrated. It is not the practice of the laboratory to
perform calibration of electrical parameters on electrical equipment (i.e. digital multi -meters,
oscilloscopes, etc.) for customers and is not intended to be perceived that way in the scope of
accreditation.
5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. FS represents
“Full Scale”.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range (Rng) or as a
percent or fraction of the reading (Rdg) plus a fixed floor specification. | ||
| 8 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Magnetic InstrumentationIndianapolis, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Control Sales and ServicesIndianapolis, IN · ~18 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Radian ResearchLafayette, IN · ~112 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tektronix, Inc. - CincinnatiCincinnati, OH · ~149 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- The Modal Shop Inc, An Amphenol CompanyCincinnati, OH · ~149 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.