KEYMKR
Isaac-Newton-Straße 4, 23562, Lübeck, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at KEYMKR?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-20829-01-00Active
- D-PL-20829-01-02Active
- D-PL-20829-01-01Active
Accredited standards
5Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-2-10; IEC 60601-2-10; DIN EN ISO 11197; DIN EN 61010-2-101⊗; IEC 61010-2-101
DIN EN 60601-1 : 2013-12; VDE 0750-1:2013-12; DIN EN 60601-2-10 : 2017-09; VDE 0750-2-10:2017-09; DIN EN 61010-2-101 : 2017-10; DIN EN ISO 11197 : 2020-05; IEC 60601-1 : 2005-12; IEC 60601-2-10 : 2012-06; IEC 61010-2-101 : 2018-10
IEC 60601-2-10Name not checked yet
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-2-10; IEC 60601-2-10; DIN EN ISO 11197; DIN EN 61010-2-101⊗; IEC 61010-2-101
DIN EN 60601-1 : 2013-12; VDE 0750-1:2013-12; DIN EN 60601-2-10 : 2017-09; VDE 0750-2-10:2017-09; DIN EN 61010-2-101 : 2017-10; DIN EN ISO 11197 : 2020-05; IEC 60601-1 : 2005-12; IEC 60601-2-10 : 2012-06; IEC 61010-2-101 : 2018-10
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
DIN EN 61010-1: 2020; IEC 61010-1:2010/AMD1:2016/COR1:2019
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-2-10; IEC 60601-2-10; DIN EN ISO 11197; DIN EN 61010-2-101⊗; IEC 61010-2-101
DIN EN 60601-1 : 2013-12; VDE 0750-1:2013-12; DIN EN 60601-2-10 : 2017-09; VDE 0750-2-10:2017-09; DIN EN 61010-2-101 : 2017-10; DIN EN ISO 11197 : 2020-05; IEC 60601-1 : 2005-12; IEC 60601-2-10 : 2012-06; IEC 61010-2-101 : 2018-10
ISO 11197Medical supply units
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-2-10; IEC 60601-2-10; DIN EN ISO 11197; DIN EN 61010-2-101⊗; IEC 61010-2-101
DIN EN 60601-1 : 2013-12; VDE 0750-1:2013-12; DIN EN 60601-2-10 : 2017-09; VDE 0750-2-10:2017-09; DIN EN 61010-2-101 : 2017-10; DIN EN ISO 11197 : 2020-05; IEC 60601-1 : 2005-12; IEC 60601-2-10 : 2012-06; IEC 61010-2-101 : 2018-10
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-20829-01-00
Accredited scope, certificate D-PL-20829-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | - | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-20829-01-02
Accredited scope, certificate D-PL-20829-01-02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | electrical | DIN EN 61010-1: 2020; IEC 61010-1:2010/AMD1:2016/COR1:2019 | Mess-, Steuer- und Laborgeräte | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-20829-01-01
Accredited scope, certificate D-PL-20829-01-01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | DIN EN ISO/IEC 17025:2018 | aktiven Medizinprodukten; IVD-Geräten | - |
| 2 | electrical | DIN EN 60601-1; IEC 60601-1; DIN EN 60601-2-10; IEC 60601-2-10; DIN EN ISO 11197; DIN EN 61010-2-101⊗; IEC 61010-2-101 | - | - |
| 3 | electrical | DIN EN 60601-1 : 2013-12; VDE 0750-1:2013-12; DIN EN 60601-2-10 : 2017-09; VDE 0750-2-10:2017-09; DIN EN 61010-2-101 : 2017-10; DIN EN ISO 11197 : 2020-05; IEC 60601-1 : 2005-12; IEC 60601-2-10 : 2012-06; IEC 61010-2-101 : 2018-10 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in Germany
- UL International GermanyNeu-Isenburg · ~446 kmDAKKSShares 2 accredited test methodsEN ISO 9001IEC 60601-1
- NEMKOPfinztal · ~558 kmDAKKSShares 2 accredited test methodsEN ISO 9001IEC 60601-1
- DEKRA Testing and CertificationStuttgart · ~579 kmDAKKSShares 2 accredited test methodsEN ISO 9001IEC 60601-1
- Kiwa PrimaraKaufbeuren · ~658 kmDAKKSShares 2 accredited test methodsEN ISO 9001IEC 60601-1
- LEFO-Institut für Lebensmittel und UmweltAhrensburg · ~33 kmDAKKSShares 1 accredited test methodEN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.