What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 22 standard numbers and the 17 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN 18031 series3
EN 18031-1
EN 18031-2
EN 18031-3
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
IEC 62680-1-2
IEC 62680-1-3
ANSI C63.4:2014; FCC MP-5-1986; ICES-001; ICES-003; ICES-005; EN 55011; EN 55013; EN 55014-1; EN 55015; EN 55032; EN 61000-3-2; IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; EN 61000-4-2; IEC 61000-4-2; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; IEC 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-3; EN 61000-6-3:2021; IEC 61000-6-4; EN IEC 61000-6-4; EN 55035; 47 CFR Part 15 B; 47 CFR Parts 15 C, E; FCC KDB 905462 D02 (v02); ANSI C63.10:2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024; RSS-GEN; RSS-210; RSS-247; RSS-310
EN IEC 62680-1-2; EN IEC 62680-1-3; EN 18031-1; EN 18031-2; EN 18031-3; ANSI C63.4:2014; FCC MP-5-1986; ANSI C63.10:2020+Cor 1:2023; FCC KDB 905462 D02 (v02)
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active7670.01
The scope document we hold says it is valid until 2028-01-31.
Accredited scope, certificate 7670.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ANSI C63.4:2014; FCC MP-5-1986; ICES-001; ICES-003; ICES-005; EN 55011; EN 55013; EN 55014-1; EN 55015; EN 55032; EN 61000-3-2; IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; EN 61000-4-2; IEC 61000-4-2; EN 61000-4-4; IEC 61000-4-4; EN 61000-4-5; IEC 61000-4-5; IEC 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-3; EN 61000-6-3:2021; IEC 61000-6-4; EN IEC 61000-6-4; EN 55035; 47 CFR Part 15 B; 47 CFR Parts 15 C, E; FCC KDB 905462 D02 (v02); ANSI C63.10:2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024; RSS-GEN; RSS-210; RSS-247; RSS-310 | - | See scope document |
| 2 | EN IEC 62680-1-2; EN IEC 62680-1-3; EN 18031-1; EN 18031-2; EN 18031-3; ANSI C63.4:2014; FCC MP-5-1986; ANSI C63.10:2020+Cor 1:2023; FCC KDB 905462 D02 (v02) | Power Transmitter | to 40000 MHz |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- Shenzhen LGT Test Service Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014EN 18031-1
- UL LLC/UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake BranchDongguanA2LAShares 2 accredited test methodsANSI C63.4:2014EN 18031-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 1 accredited test methodANSI C63.4:2014
- CTSL Testing (Dongguan) Co.,DongguanA2LAShares 1 accredited test methodANSI C63.4:2014
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .