Registers refreshed 2026-11-20.See refresh dates
United States

Element Materials Technology Rockford

3761 South Central Avenue, 61102, Rockford, IL, United States

Visit website
A2LA 214.28A2LA 214.54ISO/IEC 17025Register refreshed 2026-11-20
Part of the Element Materials Technology group: 127 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
46
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 46 standard numbers and the 38 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

KS C 9610-4-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.3probably the same standard; matched by number only

KS C 9610-4-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.4probably the same standard; matched by number only

KS C 9610-4-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.5probably the same standard; matched by number only

KS C 9610-4-5national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+2 national

National versions in the same scope

AS/NZS 61000.4.6probably the same standard; matched by number only

KS C 9610-4-6national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+2 national

National versions in the same scope

AS/NZS 61000.4.8probably the same standard; matched by number only

KS C 9610-4-8national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+2 national

National versions in the same scope

AS/NZS 61000.4.11probably the same standard; matched by number only

KS C 9610-4-11probably the same standard; matched by number only

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national

National versions in the same scope

AS/NZS 61000.6.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national

National versions in the same scope

AS/NZS 61000.6.2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC10
IEC 60439-1
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60947-1
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61558-1
IEC 61558-2-16ExclusionSome methods

Limits written next to it

IEC 61558-2-16:2021 (limited to Partial

Exclusion. Written next to it on line 3 of A2LA certificate 214.28.

IEC 61558-2-16:2021 (limited to Partial Discharge Test, Impulse Voltage Test, Insulation Resistance Test, Dielectric Withstand Test)

Some methods. Written next to it on line 3 of A2LA certificate 214.28.

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-1
IEC 61851-21-1
CISPR9
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS CISPR 11national version with changes

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers+1 national

National versions in the same scope

AS/NZS CISPR 12national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55012. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionExclusion+2 national

Limits written next to it

EN 55014-1 (excluding power disturbance measurements)

Exclusion. Written next to it on line 1 of A2LA certificate 214.28.

National versions in the same scope

AS/NZS CISPR 14-1national version with changes

KS C 9814-1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national

National versions in the same scope

AS/NZS CISPR 14-2probably the same standard; matched by number only

Certificate says EN 55014-2. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS/NZS CISPR 24identical to it

KS C 9824probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers

Certificate says EN 55025. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

KS C 9832national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion+2 national

Limits written next to it

EN 55035 (excluding Annex A-H)

Exclusion. Written next to it on line 3 of A2LA certificate 214.28.

National versions in the same scope

AS/NZS CISPR 35probably the same standard; matched by number only

KS C 9835national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

ISO5
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11451-1Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
ISO 11451-3Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: On-board transmitter simulation
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
IEC 60068 series3
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50131-1
FCC PART 15Radio Frequency Devices
GMW3172

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

214.28

The scope document we hold says it is valid until 2028-02-29.

View scope

Accredited scope, certificate 214.28

LineMethodMatrixRange
147 CFR FCC Part 15B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using MP-5:1986); ANSI C63.4:2014; ICES-003:2020; VCCI V-3 (up to 6GHz); EN 55011; CISPR 11; AS CISPR 11; KS C 9811; CISPR 11:2015 +A1:2016 +A2:2019; EN 55014-1 (excluding power disturbance measurements); CISPR 14-1 (excluding power disturbance measurements); AS/NZS CISPR 14-1; KS C 9814-1 (excluding power disturbance measurements); EN 55022; CISPR 22; AS/NZS CISPR 22; EN 55032; CISPR 32; AS/NZS CISPR 32; KS C 9832; IEC 61000-3-2:2018; IEC 61000-3-3:2013 +A1:2017; EN/IEC 61000-4-2; AS/NZS 610004.2; KS C 9610-4-2; IEC 61000-4-2:2008; EN/IEC 61000-4-3; AS/NZS 61000.4.3; KS C 9610-4-3; EN/IEC 61000-4-4; AS/NZS 61000.4.4; KS C 9610-4-4; IEC 61000-4-4:2012; EN/IEC 61000-4-5; AS/NZS 61000.4.5; KS C 9610-4-5; IEC 61000-4-5:2014 +A1:2017; EN/IEC 61000-4-6; AS/NZS 61000.4.6; KS C 9610-4-6; IEC 61000-4-6:2013--
2EN/IEC 61000-4-8; AS/NZS 61000.4.8; KS C 9610-4-8; IEC 61000-4-8:2009; EN/IEC 61000-4-11; AS/NZS 61000.4.11; KS C 9610-4-11; IEC 61000-4-11:2004 +A1:2017; MIL-STD-461C; MIL-STD-462C; MIL-STD-461E, F, and G (CE101, CE102, CE106); MIL-STD-462D (CE101, CE102, CE106); MIL-STD-462 (CE01, CE03, CE07); RTCA/DO-160 C, D, E, F, and G, Section 21; AIRBUS ABD0100.1.2, Section 8.5.1; MIL-STD-461 (RE101, RE102, RE103); MIL-STD-462D (RE101, RE102, RE103); MIL-STD-462 (RE01, RE02); RTCA/DO-160 C, D, E, F, and G, Sections 15 and 21; AIRBUS ABD0100.1.2, Section 8.5.2; RTCA/DO-160 C, D, E, F, and G, Section 25; MIL-STD-1686C; MIL-STD-461G (CS118); MIL-STD-461E, F, and G (RS101, RS103, RS105); MIL-STD-462D (RS101, RS103); MIL-STD-462 (RS01, RS02, RS03); MIL-STD-461C; MIL-STD-462C; RTCA/DO-160 C, D, E, F, and G, Section 20; AIRBUS ABD0100.1.2, Section 8.4.2; MIL-STD-461E, F, and G (CS103, CS104, CS105, CS109, CS114, CS115, CS116); MIL-STD-461C; MIL-STD-462C; MIL-STD-462D (CS103, CS104, CS105, CS109, CS114, CS115, CS116); MIL-STD-462 (CS01, CS02, CS06); RTCA/DO-160 C, D, E, F, and G, Section 20; AIRBUS ABD0100.1.2, Section 8.4.1; MIL-STD-461D, E, F, G, (RS101); MIL-STD-462 (RS01); MIL-STD-461C; MIL-STD-462C; RTCA/DO-160 C, D, E, F, G, Section 15; MIL-STD-461F (CS106); RTCA/DO-160 C, D, E, F, and G, Section 17; MIL-STD-704A, B, C, D, E, and F; RTCA/DO-160 C, D, E, F, and G, Section 16; MIL-STD-461D, E, F, and G (CS101); MIL-STD-462 (CS01); MIL-STD-461C; MIL-STD-462C--
3RTCA/DO-160 C, D, E, F, and G, Section 19; AIRBUS ABD0100.1.2, Section 8.3; MIL-STD-461G (CS117); RTCA/DO-160 C, D, E, F, and G, Section 22; AIRBUS ABD0100.1.2, Section 8.6.1; AIRBUS ABD0100.1.2, Section 8.6.2; EN 55012; CISPR 12; AS/NZS CISPR 12; CISPR 25 for RE (2016, 2021) Section 6.5; CISPR 25 for CE (2016, 2021) Sections 6.3 and 6.4; EN 55025 (sections 6.3 and 6.4); ECE Regulation 10; ISO 10605; ISO 10605:2008; ISO 11451-1; ISO 11452-4; ISO 11451-3; ISO 7637-2; EN/IEC 61000-6-1; AS/NZS 61000.6.1; EN/IEC 61000-6-2; AS/NZS 61000.6.2; EN/IEC 61000-6-3; EN/IEC 61000-6-4; CISPR 14-2; EN 55014-2; AS/NZS CISPR 14-2; CISPR 24; EN 55024; AS/NZS CISPR 24; KS C 9824; CISPR 35 (excluding Annex A-H); EN 55035 (excluding Annex A-H); AS/NZS CISPR 35; KS C 9835 (excluding Annex A-H); BS EN/IEC 60601-1-2 (proximity magnetic fields frequency range 30 kHz – 13.56 MHz); IEC 60601-1-2:2020; BS EN/IEC 60947-1; BS EN/IEC 60439-1; EN 61326-2-6:2013; EN 61326-2-6:2021; BS EN/IEC 61326-1; BS EN/IEC 61326-2; BS EN 50130-4; BS EN 50131-1; EN 61800-3; IEC 61800-3 (up to 75A, 1000V); IEC 61851-21-1:2017; IEC 61800-5-1:2022; IEC 61558-1:2017; IEC 61558-2-16:2021 (limited to Partial Discharge Test, Impulse Voltage Test, Insulation Resistance Test, Dielectric Withstand Test)--
4ANSI C63.4:2014; FCC MP-5 (February 1986)Unintentional Radiators; Industrial, Scientific, and Medical Equipmentto 13500 MHz
5ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

214.54

The scope document we hold says it is valid until 2028-02-29.

View scope

Accredited scope, certificate 214.54

LineMethodMatrixRange
1RTCA/DO-160, Section 11; MIL-STD-202, Method 215; MIL-STD-810, Method 504; RTCA/DO-160, Section 6; MIL-STD-810, Method 507; MIL-STD-202, Method 103; IEC 60068-2-2:2007; IEC 60068-2-78:2025; RTCA/DO-160, Sections 4 & 5; MIL-STD-810, Method 520; MIL-STD-810, Method 501; MIL-STD-810, Method 502; MIL-STD-810, Method 503; RTCA/DO-160, Section 4; MIL-STD-810, Method 520; MIL-STD-810, Method 505; MIL-STD-202, Method 105; RTCA/DO-160, Section 24; MIL-STD-810, Method 521industrial drives; tractor components; automotive system and subsystems; consumer electronics; electrical power/distribution equipment-
2RTCA/DO-160, Sections 7 & 8; MIL-STD-810, Method 520; MIL-STD-202, Method 201; MIL-STD-202, Method 202; MIL-STD-202, Method 204; MIL-STD-202, Method 213; MIL-STD-202, Method 214; MIL-STD-202, Method 212; MIL-STD-810, Method 513; Qualmark HALT Guidelines 933-0336; GMW3172; IEC 60068-2-14; IPC9592A; ASTM B117; RTCA/DO-160 Section 14; MIL-STD-810, Method 509; MIL-STD-202, Method 10; MIL-STD-810H Method 506.6 Procedure III; RTCA/DO-160 Section 10--
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3761 South Central Avenue, Rockford, IL, 61102, US

42.27139, -89.09397

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.