Vitrek

900 N. State Street, 60441, Lockport, IL, United States

Visit website
A2LA 3678.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 3678.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3678.01) 2/7/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Measure (0 to 0.1) mA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (100 to 1000) mA 33 µA/A + 900 pA 31 µA/A + 6 nA 31 µA/A + 60 nA 48 µA/A + 600 nA 0.013 % + 12 µA HP 3458A Resistance – Generate, Fixed Points 0.05 Ω 0.100 Ω 1.0 Ω 10.0 Ω 100.0 Ω 1.0 kΩ 10.0 kΩ 100.0 kΩ 1.0 MΩ 5.0 MΩ 10.0 MΩ 100.0 MΩ 1.0 GΩ 0.066 % 0.072 % 0.066 % 37 µΩ/Ω 28 µΩ/Ω 24 µΩ/Ω 0.018 % 84 µΩ/Ω 38 µΩ/Ω 63 µΩ/Ω 0.014 % 0.021 % 0.06 % (IET HARS-LX-1) Decade BOC) Vitrek 0.05 Ω Vitrek SR502 Vitrek SR502 Vitrek 10 Ω ESI R925C Vitrek 1 kΩ Vitrek 10 k Vitrek 4610 Vitrek 4610 Vitrek CAL 5M Vitrek 4610 Vitrek 4610 Vitrek 4610 Resistance – Measure Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 0.015 % + 50 µΩ 21 µΩ/Ω + 500 µΩ 14 µΩ/Ω + 500 µΩ 14 µΩ/Ω + 5 mΩ 14 µΩ/Ω + 50 mΩ 20 µΩ/Ω + 2.0 Ω 90 µΩ/Ω + 100 Ω 0.073 % + 1 kΩ 0.62 % + 10 kΩ HP 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3678.01) 2/7/2025 Page 3 of 4 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate Up to 23 V (23 to 45) V (45 to 90) V (90 to 180) V (180 to 360) V (360 to 650) V (650 to 1008) V 50 Hz 50, 100 or 400 Hz 1.7 mV 4.0 mV 6.5 mV 13 mV 33 mV 61 mV 95 mV Fluke 6105A AC Voltage – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (1 to 10) kV (10 to 30) kV (30 to 50) kV (50 to 70) kV 40 Hz to 1 kHz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (50 to 60) Hz 83 µV/V + 2.0 µV 83 µV/V + 20 µV 83 µV/V + 2.0 mV 0.024 % + 2.0 mV 0.041 % + 2.0 mV 0.14 % + 2.0 mV 0.028 % 0.019 % 0.016 % 0.022 % HP 3458A Vitrek 4710 ratiometric transfer standard with HP3458A AC Current – Generate Up to 0.1 A (0.1 to 1.0) A (1.0 to 10.0) A (10.0 to 20.0) A (20.0 to 40.0) A (50 to 60) Hz 71 µA/A + 2.5 µA 69 µA/A + 10 µA 74 µA/A + 100 µA 73 µA/A + 200 µA 73 µA/A + 500 µA Fluke 6105A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3678.01) 2/7/2025 Page 4 of 4 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Measure (0 to 0.1) mA (0.1 to 1.0) mA (1.0 to 10.0) mA (10.0 to 100.0) mA (100.0 to 1000.0) mA (1 to 20) A (20 to 40) A (45 to 100) Hz (45 to 100) Hz 0.14 % + 0.03 µA 0.07 % + 0.2 µA 0.072 % + 2.0 µA 0.072 % + 20 µA 0.095 % + 200 µA 0.26 % 0.78 % HP 3458A HP 3458A with 50 mΩ shunt _____________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measuran d in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction /percent of the reading plus a fixed floor specification. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
5ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

900 N. State Street, Lockport, IL, 60441, US

41.58948, -88.05784

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.