Arpae Emilia-Romagna - Direzione Tecnica - Laboratorio Multisito - Sede Secondaria di Bologna (SLM-BO) e Centro Tematico Regionale-Servizi Idrici (CTR_SI)
Via Rocchi, 19, 40138, Bologna, Italy
Visit website- Accredited standards
- 16
- ACCREDIA certificate
- 1
- Sites in our directory
- 6
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 16 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO11
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 11731Water quality - Enumeration of Legionella
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15587-1Water quality - Digestion for the determination of selected elements in water - Part 1: Aqua regia digestion
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
ISO 17943Water quality - Determination of volatile organic compounds in water - Method using headspace solid-phase micro-extraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS)
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
EN3
EN 13946
EN 14407
EN 27888Water quality - Determination of electrical conductivity
Other standards2
EPA 300.1
EPA 8272
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; UNI EN ISO 16266:2008; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; APAT CNR IRSA 4020 Man 29 2003; UNI EN 27888:1995; UNI EN 13946:2014; UNI EN 14407:2014; ISO 15587-1:2002; UNI EN ISO 17294-2:2023; ISO 15705:2002; UNI 11757:2019; APAT CNR IRSA 2090 B Man 29 2003; UNI ISO 23695:2023
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; EPA 8272 2007; ISO 17943:2016; EPA 300.1 1997 part B + EC 1999; UNI EN ISO 14189:2016
EPA 8272 2007; UNI CEI EN ISO/IEC 17025:2018
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
4 lines
ISO/IEC 17025
Active00203
Accredited scope, certificate 00203
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; EPA 8272 2007; ISO 17943:2016; EPA 300.1 1997 part B + EC 1999; UNI EN ISO 14189:2016 | Drinking water | 0.003 to µg/L |
| 2 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; UNI EN ISO 16266:2008; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; APAT CNR IRSA 4020 Man 29 2003; UNI EN 27888:1995; UNI EN 13946:2014; UNI EN 14407:2014; ISO 15587-1:2002; UNI EN ISO 17294-2:2023; ISO 15705:2002; UNI 11757:2019; APAT CNR IRSA 2090 B Man 29 2003; UNI ISO 23695:2023 | Drinking water | 10 to 20000 µS/cm |
| 3 | EPA 8272 2007; UNI CEI EN ISO/IEC 17025:2018 | - | 0.003 to µg/L |
| 4 | ISPRA 2010 Man 111 2014; APAT CNR IRSA 9010 Man 29 2003 | Acque superficiali di fiume/Surface river water; Acque superficiali fluenti/Surface water flowing | 1 to 14 |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
5 other sites in this organization
Labs with overlapping accredited scope in Italy
- C.I.A. LAB S.R.L.Ascoli Piceno · ~250 kmACCREDIAShares 3 accredited methods and materialsEN ISO 11731:2017EN ISO 6222:2001Drinking water
- ALS ItaliaMoncalieri · ~297 kmACCREDIAShares 3 accredited methods and materialsEN ISO 11731:2017EN ISO 6222:2001Drinking water
- EurocertGranarolo dell'Emilia · ~9 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
- BIOKIMModena · ~35 kmACCREDIAShares 2 accredited methods and materialsEN ISO 11731:2017Drinking water
- TEST S.r.l.Formigine · ~42 kmACCREDIAShares 2 accredited methods and materialsEN ISO 11731:2017Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.