LAW Calibration
41 Spring Hill Road, 04072, Saco, ME, United States
Visit website- Scope lines
- 16
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 16 scope lines.
A2LA certificate 2398.01 · 16 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 4 to 10 pH |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 2 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Calipers3
(cont)
(8 to 10) in
(10 to 12) in
(12 to 16) in
(16 to 20) in
(20 to 30) in
(30 to 40) in
52 μin
56 μin
65 μin
75 μin
110 μin
140 μin
Gage blocks, gage
block adapter, surface
plate
Dial Indicators3
Up to 1 in
12 μin
Gage blocks,
micrometer head
Test Indicators3
Up to 1 in
39 μin
Gage blocks
Gage Blocks
(0.05 to 0.4) in
(0.4 to 0.9) in
(0.9 to 1) in
(1 to 2) in
(2 to 3) in
(3 to 4) in
(4 to 5) in
(5 to 6) in
(6 to 8) in
(8 to 10) in
(10 to 12) in
(12 to 16) in
7.1 μin
8.2 μin
8.8 μin
11 μin
14 μin
17 μin
22 μin
23 μin
30 μin
36 μin
42 μin
54 μin
Gage blocks,
comparator, lab
master
Height Gages3
(0.1 to 1) in
(1 to 3) in
(3 to 4) in
(4 to 6) in
(6 to 8) in
(8 to 10) in
(10 to 12) in
(12 to 16) in
(16 to 20) in
(20 to 30) in
(30 to 40) in
77 μin
78 μin
79 μin
80 μin
82 μin
84 μin
87 μin
93 μin
100 μin
130 μin
150 μin
Gage blocks, surface
plate | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 3 of 15
Parameter/Equipment
Range
CMC2 (±)
Comments
Micrometers3
(0.1 to 0.25) in
(0.25 to 0.5) in
(0.5 to 0.75) in
(0.75 to 1) in
(1 to 2) in
(2 to 3) in
(3 to 4) in
(4 to 5) in
(5 to 6) in
(6 to 7) in
(7 to 8) in
(8 to 10) in
(10 to 12) in
8 μin
8.9 μin
9 μin
9.5 μin
11 μin
14 μin
17 μin
22 μin
23 μin
28 μin
29 μin
35 μin
40 μin
Gage blocks, surface
plate
Rulers & Tape Measures
Up to 25 ft
0.020 in
Gage blocks
Optical Comparators3 –
X & Y
Up to 5 in
(6 to 12) in
93 μin
200 μin
Glass standard
Microscopes3 –
X & Y
Up to 1 in
54 μin
Stage micrometer
III. Electrical – DC/Low Frequency
Parameter/Range Frequency CMC2, 4 (±) Comments
AC Voltage – Generate
(0 to 12) mV
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.19 % + 7 µV
0.068 % + 7 µV
0.012 % + 6 µV
0.029 % + 6 µV
0.12 % + 15 µV
0.62 % + 30 µV
0.62 % + 30 µV
Fluke 5560A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 4 of 15
Parameter/Range Frequency CMC2, 4 (±) Comments
AC Voltage – Generate
(cont)
(12 to 120) mV
120 mV to 1.2 V
(1.2 to 12) V
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(33 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.19 % + 7 µV
0.068 % + 7 µV
0.011 % + 6 µV
0.027 % + 8 µV
0.062 % + 20 µV
0.16 % + 30 µV
0.16 % + 30 µV
0.19 % + 75 µV
0.068 % + 70 µV
0.011 % + 60 µV
0.023 % + 14 µV
0.054 % + 40 µV
0.15 % + 80 µV
0.15 % + 80 µV
0.19 % + 750 µV
0.068 % + 750 µV
0.011 % + 350 µV
0.023 % + 50 µV
0.054 % + 13 µV
0.16 % + 600 µV
0.16 % + 600 µV
0.19 % + 7.5 mV
0.068 % + 7.5 mV
0.011 % + 3.5 mV
0.023 % + 500 µV
0.054 % + 1.3 mV
0.16 % + 20 mV
0.19 % + 75 mV
0.068 % + 75 mV
0.011 % + 8 mV
0.023 % + 8 mV
0.12 % + 13 mV
0.19 % + 75 mV
0.068 % + 75 mV
0.011 % + 80 mV
Fluke 5560A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 5 of 15
Parameter/Range Frequency CMC2, 4 (±) Comments
AC Voltage – Measure
(0 to 10) mV
(10 to 100) mV
(.1 to 1) V
(1 to 10) V
(10 to 100) V
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300 kHz
(300 to 1000)kHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(300 to 1000) kHz
0.025 % + 1.1 µV
0.037 % + 1.1 µV
0.034 % + 1.1 µV
0.3 % + 1.1 µV
1 % + 4 µV
2 % + 4 µV
0.0068 % + 0.5 µV
0.011 % + 0.5 µV
0.021 % + 1 µV
0.051 % + 5 µV
0.2 % + 30 µV
1 % + 100 µV
1.5 % + 500 µV
4 % + 1 mV
8 % + 1 mV
15 % + 1 mV
0.0064 % + 5 µV
0.011 % + 5 µV
0.021 % + 10 µV
0.051 % + 50 µV
0.2 % + 300 µV
1 % + 1 mV
1.5 % + 5 mV
4 % + 10 mV
8 % + 10 mV
15 % + 10 mV
0.0064 % + 50 µV
0.011 % + 50 µV
0.021 % + 100 µV
0.051 % + 500 µV
0.2 % + 3 mV
1 % + 10 mV
1.5 % + 50 mV
4 % + 100 mV
8 % + 100 mV
15 % + 100 mV
0.007 % + 500 µV
0.009 % + 500 µV
0.021 % + 1 mV
0.051 % + 5 mV
0.35 % + 50 mV
1 % + 500 mV
Fluke 8588A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 6 of 15
Parameter/Equipment
Frequency CMC2, 4 (±) Comments
AC Voltage – Measure
(cont)
(100 to 1050) V
1 to 2000) Hz
2 to 10) kHz
10 to 30) kHz
30 to 100) kHz
0.009 % + 25 mV
0.009 % + 25 mV
0.021 % + 25 mV
0.051 % + 100 mV
Fluke 8588A
AC Current – Generate
(0 to 120) µA
(120 to 1.2) mA
(1.2 to 12) mA
(12 to 120) mA
120 mA to 1.2 A
(1.2 to 3.1) A
(3.1 to 12) A
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.019 % + 10 nA
0.019 % + 10 nA
0.019 % + 10 nA
0.12 % + 40 nA
0.39 % + 1 µA
0.019 % + 100 nA
0.019 % + 100 nA
0.019 % + 100 nA
0.12 % + 100 nA
0.39 % + 5 µA
0.019 % + 1 µA
0.019 % + 1 µA
0.019 % + 1 µA
0.12 % + 1 µA
0.39 % + 10 µA
0.019 % + 10 µA
0.019 % + 5 µA
0.019 % + 8 µA
0.12 % + 10 µA
0.39 % + 100 µA
0.019 % + 100 µA
0.019 % + 50 µA
0.019 % + 80 µA
0.12 % + 300 µA
0.39 % + 300 µA
0.029 % + 500 µA
0.023 % + 300 µA
0.029 % + 300 µA
0.19 % + 500 µA
0.029 % + 1 mA
0.023 % + 500 µA
0.029 % + 800 µA
0.19 % + 1 mA
Fluke 5560A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 7 of 15
Parameter/Equipment
Frequency CMC2, 4 (±) Comments
AC Current – Generate
(cont)
(12 to 30.2) A
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
0.078 % + 10 mA
0.054 % + 8 mA
0.39 % + 8 mA
Fluke 5560A
AC Current – Measure
(0-10) µA
(10 to 100) µA
(0.1-1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 30) A
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(1 to 2000) Hz
(2 to 10) kHz
(10 to 30) kHz
(1 to 2000) Hz
(2 to 10) kHz
(1 to 2000) Hz
(2 to 10) kHz
0.2 % + 2.5 nA
0.2 % + 2.5 nA
0.2 % + 2.5 nA
0.26 % + 5 nA
0.51 % + 5 nA
0.072 % + 5 nA
0.4 % + 10 nA
0.26 % + 50 nA
0.51 % + 50 nA
0.072 % + 50 nA
0.4 % + 100 nA
0.26 % + 500 nA
0.51 % + 500 nA
0.072 % + 500 nA
0.4 % + 1 µA
0.26 % + 5 µA
0.5 % + 5 µA
0.07 % + 5 µA
0.26 % + 100 µA
0.51 % + 100 µA
0.071 % + 100 µA
0.08 % + 500 µA
0.08 % + 500 µA
0.08 % + 12 mA
0.12 % + 12 mA
Fluke 8588A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 8 of 15
Parameter/Equipment
Range CMC2, 4 (±) Comments
DC Voltage – Generate
(0.00 to 120) mV
120 mV to 1.2 V
(1.2 to 12) V
(12 to 120) V
(120 to 1020) V
0.0009 % + 0.8 µV
0.0006 % + 1 µV
0.0006 % + 10 µV
0.0009 % + 100 µV
0.0009 % + 1000 µV
Fluke 5560A
DC Voltage – Measure
(0.01 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.000 52 % + 0.2 µV
0.000 28 % + 0.3 µV
0.000 28 % + 0.5 µV
0.000 41 % + 30 µV
0.000 43 % + 500 µV
Fluke 8588A
DC Current – Generate
(0 to 120) µA
120 µA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
120 mA to 1.2 A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
0.0097 % + 6 nA
0.0078 % + 15 nA
0.0078 % + 80 nA
0.0078 % + 800 nA
0.012 % + 10 µA
0.82 % + 150 µA
0.023 % + 250 µA
0.078 % + 500 µA
Fluke 5560A
DC Current – Measure
(0 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 30) A
0.0024 % + 0.4 nA
0.000 83 % + 0.4 nA
0.000 76 % + 4 nA
0.000 89 % + 40 nA
0.0033 % + 1 µA
0.01 % + 100 µA
0.017 % + 400 µA
0.049 % + 4.4 mA
Fluke 8588A
Resistance – Generate
(0 to 12) Ω
(12 to 120) Ω
(0.12 to 1.2) kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
(0.12 to 1.2) MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(0.12 to 1.2) GΩ
0.0019 % + 1 mΩ
0.0019 % + 1 mΩ
0.0019 % + 2 mΩ
0.0019 % + 20 mΩ
0.0019 % + 200 mΩ
0.0019 % + 2 Ω
0.0027 % + 30 Ω
0.033 % + 2.5 kΩ
0.31 % + 100 kΩ
Fluke 5560A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 9 of 15
Parameter/Equipment
Range CMC2, 4 (±) Comments
Resistance – Measure
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
0.0011 % + 4 µΩ
0.000 81 % + 14 µΩ
0.000 85 % + 50 µΩ
0.000 71 % + 500 µΩ
0.000 72 % + 5 mΩ
0.000 73 % + 50 mΩ
0.000 82 % + 1 Ω
0.0012 % + .01 kΩ
0.015 % + 10 kΩ
0.056 % + 1 MΩ
Fluke 8588A
Capacitance – Generate
(0.2 to 1.2) nF
(1.2 to 12) nF
(12 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
0.09 % + 2 pF
0.09 % + 5 pF
0.1 % + 30 pF
0.1 % + 300 pF
0.1 % + 3 nF
0.12 % + 25 nF
0.19 % + 250 nF
0.19 % + 3 µF
0.39 % + 30 µF
Fluke 5560A
Capacitance – Measure
1 nF
10 nF
100 nF
1 µF
10 µF
100 µF
1 mF
10 mF
100 mF
0.1 % + 1 pF
0.06 % + 2 pF
0.04 % + 10 pF
0.04 % + 100 pF
0.04 % + 1 nF
0.06 % + 10 nF
0.06 % + 0.1 µF
0.07 % + 1 µF
0.07 % + 10 µF
Fluke 8588A
Inductance – Generate
120 µH
1.2 mH
12 mH
120 mH
1.2 H
12 H
120 H
0.16 % + 200 nH
0.09 % + 1 µH
0.09 % + 10 µH
0.09 % + 100 µH
0.12 % + 1 mH
0.16 % + 10 mH
0.19 % + 100 mH
Fluke 8588A | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 10 of 15
Parameter/Equipment
Range CMC2, 4 (±) Comments
Electrical Simulation of
Thermocouples3 –
Generate/Measure
Type B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1370) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1760) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1760) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.34 °C
0.26 °C
0.23 °C
0.26 °C
0.31 °C
0.11 °C
0.09 °C
0.12 °C
0.16 °C
0.19 °C
0.1 °C
0.09 °C
0.11 °C
0.16 °C
0.22 °C
0.1 °C
0.09 °C
0.16 °C
0.27 °C
0.26 °C
0.12 °C
0.09 °C
0.09 °C
0.16 °C
0.4 °C
0.23 °C
0.22 °C
0.27 °C
0.33 °C
0.24 °C
0.26 °C
0.36 °C
0.47 °C
0.16 °C
0.1 °C
0.09 °C
Fluke 5560A | to 1820 °C |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 11 of 15
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Electrical Simulation of
RTDs3 –
PT100 PRT
PT1000 PRT
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.04 °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.18 °C
0.02 °C
0.02 °C
0.03 °C
0.04 °C
0.05 °C
0.05 °C
0.05 °C
0.18 °C
Fluke 5560A
Pressure – Measure &
Measuring Equipment
(-0.5 to 0.5) in H2O
(-25 to 25) mbar
(-0.95 to 1) bar
(1 to 2.5) bar
(2.5 to 40) bar
(60 to 110) kPa
(-13.5 to 300) psi
(300 to 3000) psi
(3000 to 10,000) psi
(10k to 20k) psi
0.000 76 in H2O
0.015 mbar
0.000 32 bar
0.000 65 bar
0.0098 bar
0.064 kPa
0.074 psi
1.8 psi
2.6 psi
12 psi
Handheld pressure
calibrator
20000 psi pressure
gauge
Torque Measure -
Wrenches
(4 to 50) lbf·in
(50 to 500) lbf·in
(25 to 250) lbf∙ft
(250 to 750) lbf∙ft
(750 to 2000) lbf∙ft
0.38 %
0.78 %
0.63 %
0.67 %
0.72 %
AWS torque
transducers | ||
| 12 | Ohaus balances – gravimetric method | - | See scope document |
| 13 | OIML Class E1; ASTM Class 1 | - | See scope document |
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2398.01) Revised 2/25/2026 Page 14 of 15
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Generate
1 Hz to 2 MHz
0.0082 %
Fluke 5560A
Frequency – Measure
(1 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
10 kHz to 1 MHz
2.3 µHz/Hz + 17 µHz
2.3 µHz/Hz + 170 µHz
2.3 µHz/Hz + 1.7 mHz
2.3 µHz/Hz + 1.7 Hz
Multimeter
Stopwatch & Timers
Up to 19.99 s/day
0.033 s/day
Helmut Klein
timometer | 1 to 2000000 Hz |
| 15 | LAW - 9001 | Automatic Field Sprinklers | 50 to 135 °C |
| 16 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Associated Environmental SystemsNorth Chelmsford, MA · ~123 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-Tek CompanyNorth Billerica, MA · ~123 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hayes Instrument ServiceBillerica, MA · ~124 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hitachi High-Tech AmericaWestford, MA · ~131 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M Precision Laboratories,Shirley, MA · ~145 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.