CONNECTICUT CALIBRATION TECHNOLOGIES, INC., dba CONNECTICUT CALIBRATION
327 S. Main Street, 06470, Newtown, CT, United States
Visit website- Scope lines
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 14 scope lines.
A2LA certificate 2010.01 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | 0 to 360 ° |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 2 of 13
Parameter/Equipment
Range CMC2, 5 (±) Comments
Pins
(0.011 to 1) in
55 µin
Laser micrometer,
master pins
Crimpers3
(0.011 to 0.5) in
240 µin
Meyer plus,
Meyer minus
Micrometers3
Up to 12.000 in
Up to 100 mm
(32 + 2.5L + 0.6RD) µin
(0.92 + 0.003L + 0.6RD) µm
Gage blocks
Fixture & Attribute
Gages
Up to 6 in
(76 + 18L) µin
Micrometer
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
DC Voltage – Generate
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(100 to 1000) V
(1 to 5) kV
(5 to 10) kV
35 µV/V + 1 µV
17 µV/V + 2 µV
20 µV/V + 20 µV
25 µV/V + 150 µV
20 µV/V + 1500 µV
9.7 V
11 V
Fluke 5520A
Keithley 2290-10
DC Voltage – Measure3
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1100) V
(1 to 40) kV
29 µV/V + 0.3 µV
13 µV/V + 0.3 µV
15 µV/V + 0.5 µV
18 µV/V + 30 µV
10 µV/V + 100 µV
2.5 %
HP 3458A opt 002
Amprobe HU231-
10A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 3 of 13
Parameter/Equipment
Range CMC2, 4, 6 (±) Comments
DC Current – Generate
Clamp-on Only
(0 to 330) µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20) A
(20 to 150) A
(150 to 1000) A
0.02 % + 0.02 µA
0.01 % + 0.05 µA
0.01 % + 0.25 µA
0.011 % + 2.5 µA
0.022 % + 40 µA
0.039 % + 40 µA
0.051 % + 500 µA
0.1 % + 750 µA
0.64 % + 0.16 A
0.65 % + 0.58 A
Fluke 5520A
with 5500A coil
DC Current – Measure3
(0 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 50) A
0.015 % + 40 pA
0.015 % + 100 pA
35 µA/A + 800 pA
37 µA/A + 5 nA
61 µA/A + 50 nA
0.012 % + 500 nA
0.3 %
HP 3458A opt 002
Agilent 3458A
with Empro 50-50
DC Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
56 µΩ/Ω + 0.001 Ω
51 µΩ/Ω + 0.0018 Ω
43 µΩ/Ω + 0.0014 Ω
32 µΩ/Ω + 0.002 Ω
30 µΩ/Ω + 0.002 Ω
30 µΩ/Ω + 0.02 Ω
29 µΩ/Ω + 0.02 Ω
30 µΩ/Ω + 0.2 Ω
29 µΩ/Ω + 0.2 Ω
37 µΩ/Ω + 2 Ω
34 µΩ/Ω + 2 Ω
150 µΩ/Ω + 30 Ω
0.014 % + 50 Ω
0.047 % + 2.5 kΩ
0.45 % + 3 kΩ
0.46 % + 100 kΩ
1.5 % + 500 kΩ
Dale ECN 250
Fluke 5520A
DC Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
33 µΩ/Ω + 50 µΩ
34 µΩ/Ω + 500 µΩ
16 µΩ/Ω + 500 µΩ
14 µΩ/Ω + 5 mΩ
14 µΩ/Ω + 50 mΩ
HP 3458A opt 002 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 4 of 13
Parameter/Equipment
Range CMC2, 6 (±) Comments
DC Resistance – Measure3
(cont)
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
19 µΩ/Ω + 2 Ω
57 µΩ/Ω + 100 Ω
0.063 % + 1 kΩ
0.5 % + 10 kΩ
HP 3458A opt 002
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.092 % + 6 µV
0.048 % + 6 µV
0.026 % + 6 µV
0.10 % + 6 µV
0.35 % + 12 µV
0.80 % + 50 µV
0.033 % + 8 µV
0.019 % + 8 µV
0.020 % + 8 µV
0.038 % + 8 µV
0.081 % + 32 µV
0.20 % + 70 µV
0.034 % + 50 µV
0.018 % + 60 µV
0.024 % + 60 µV
0.037 % + 50 µV
0.074 % + 130 µV
0.24 % + 600 µV
0.033 % + 650 µV
0.020 % + 600 µV
0.027 % + 600 µV
0.039 % + 600 µV
0.092 % + 1.6 mV
0.027 % + 2 mV
0.028 % + 6 mV
0.031 % + 6 mV
0.037 % + 6 mV
0.20 % + 50 mV
0.035 % + 10mV
0.029 % + 10 mV
0.034 % + 10 mV
Fluke 5520A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 5 of 13
Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments
AC Voltage – Measure3
(1 to 10) mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) kV
(1 to 20) kV
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(60 to 400) Hz
400 Hz to 75 MHz
0.03 % + 1.1 µV
0.04 % + 1.1 µV
0.1 % + 1.1 µV
0.5 % + 1.1 µV
4 % + 2 µV
0.019 % + 2 µV
0.022 % + 2 µV
0.04 % + 2 µV
0.08 % + 2 µV
0.3 % + 10 µV
1 % + 10 µV
0.013 % + 0.2mV
0.021 % + 0.2mV
0.04 % + 0.2mV
0.08 % + 0.2mV
0.3 % + 1 mV
1 % + 1 mV
0.015 % + 0.2mV
0.02 % + 0.2mV
0.04 % + 0.2mV
0.09 % + 0.2mV
0.3 % + 11 mV
1 % + 1 mV
0.03 % + 2 mV
0.03 % + 2 mV
0.042 % + 2 mV
0.12 % + 10 mV
0.4 % + 10 mV
0.06 % + 20 mV
0.08 % + 20 mV
0.13 % + 20 mV
6.4 %
3.6 % + 0.6R
HP 3458A opt 002
Amprobe HU231-
10A
Tektronix P6015 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 6 of 13
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Current – Generate
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3.0) A
(3 to 11) A
(11 to 20.5) A
Clamp-On Only:
(20 to 150) A
(150 to 550) A
(550 to 1000) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1.0 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
@ 60 Hz
@ 60 Hz
@ 60 Hz
0.23 % + 0.1 µA
0.19 % + 0.1 µA
0.17 % + 0.1 µA
0.31 % + 0.15 µA
0.81 % + 0.2 µA
1.6 % + 0.4 µA
0.21 % + 0.15 µA
0.15 % + 0.15µA
0.13 % + 0.15 µA
0.21 % + 0.2 µA
0.51 % + 0.30 µA
1.0 % + 0.6 µA
0.18 % + 1.0 µA
0.09 % + 2.0 µA
0.08 % + 2.0 µA
0.11 % + 2.0 µA
0.22 % + 3.0 µA
0.41 % + 4.0 µA
0.20 % + 20 µA
0.10 % + 20 µA
0.09 % + 20 µA
0.13 % + 50 µA
0.21 % + 100 µA
0.41 % + 200 µA
0.19 % + 100 µA
0.10 % + 100 µA
1.5 % + 1 mA
2.5 % + 5 mA
0.59 % + 2 mA
0.14 % + 2 mA
3.0 % + 2 mA
0.16 % + 5 mA
0.52 % + 5 mA
3.0 % + 5 mA
0.63 % + 0.16 A
0.85 % + 0.58 A
0.64 % + 0.58 A
Fluke 5520A
with 5500A coil | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 7 of 13
Parameter/Range
Frequency CMC2, 6 (±) Comments
AC Current – Measure3
(5 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 100 Hz
100 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
0.41 % + 30 nA
0.17 % + 30 nA
0.10 % + 30 nA
0.08 % + 30 nA
0.40 % + 0.2 µA
0.15 % + 0.2 µA
0.062 % + 0.2 µA
0.033 % + 0.2 µA
0.071 % + 0.2 µA
0.40 % + 0.4 µA
0.40 % + 2 µA
0.15 % + 2 µA
0.061 % + 2 µA
0.034 % + 2 µA
0.067 % + 2 µA
0.40 % + 4 µA
0.40 % + 20 µA
0.15 % + 20 µA
0.061 % + 20 µA
0.031 % + 20 µA
0.062 % + 20 µA
0.40 % + 40 µA
0.40 % + 0.2 mA
0.16 % + 0.2 mA
0.081 % + 0.2mA
0.10 % + 0.2 mA
0.30 % + 0.2 mA
1.0 % + 0.4 mA
HP 3458A opt 002 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 8 of 13
Parameter/Range
Frequency CMC2, 6 (±) Comments
Capacitance – Generate
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
Up to 80 Hz
Up to 50 Hz
Up to 20 Hz
Up to 6 Hz
Up to 2 Hz
Up to 0.6 Hz
Up to 0.2 Hz
3.4 % + 0.01 nF
1.6 % + 0.01 nF
0.58 % + 0.01 nF
0.28 % + 0.01 nF
0.28 % + 0.1 nF
0.28 % + 0.1 nF
0.28 % + 0.3 nF
0.28 % + 1 nF
0.27 % + 3 nF
0.27 % + 10 nF
0.41 % + 30 nF
0.46 % + 100 nF
0.45 % + 300 nF
0.45 % + 1 nF
0.45 % + 3 nF
0.45 % + 10 nF
0.75 % + 30 nF
1.1 % + 100 nF
Fluke 5520A
Inductance – Generate3
@ 100 mH
@ 1 kHz
0.1 mH
GenRad 1842L
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple
Indicators3 –
Type E
Type J
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.55 °C
0.28 °C
0.27 °C
0.28 °C
0.32 °C
0.36 °C
0.28 °C
0.27 °C
0.29 °C
0.33 °C
Fluke 5520A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 9 of 13
Parameter/Equipment
Range CMC2 (±) Comments
Electrical Calibration of
Thermocouple
Indicators3 – (cont)
Type K
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.40 °C
0.30 °C
0.28 °C
0.35 °C
0.46 °C
0.67 °C
0.34 °C
0.28 °C
0.27 °C
Fluke 5520A
Electrical Calibration
of RTDs –
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 1000 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.07 °C
0.07 °C
0.09 °C
0.10 °C
0.11 °C
0.13 °C
0.24 °C
0.08 °C
0.08 °C
0.08 °C
0.09 °C
0.14 °C
0.15 °C
0.16 °C
0.17 °C
0.04 °C
0.04 °C
0.05 °C
0.05 °C
0.06 °C
0.07 °C
0.07 °C
0.23 °C
Fluke 5520A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 10 of 13
Parameter/Equipment
Range CMC2, 4 (±) Comments
Electrical Calibration
of RTDs –
Pt 3916, 100 Ω
Pt 3926, 100 Ω
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.26 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.09 °C
0.10 °C
0.11 °C
0.24 °C
0.07 °C
0.07 °C
0.09 °C
0.10 °C
0.11 °C
0.13 °C
Fluke 5520A
Oscilloscopes –
Amplitude
Square Wave Signal,
50 Ω @ 1 kHz
1 MΩ
Leveled Sine Wave
Characteristics Into 50 Ω
Square Wave Signal
Frequency Accuracy
Amplitude (Relative to 50
kHz)
Time Marker Into
50 Ω
(0 to 6.6) V
1 mV to 130 V
50 kHz (Reference)
50 kHz to 100MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
(10 to 100) kHz
50 kHz to 100 MHz
(101 to 300) MHz
(301 to 600) MHz
(601 to 1100) MHz
5 s to 50 ms
20 ms to 10 ns
(5 to 2) ns
0.26 % + 40 µV
0.10 % + 40 µV
2 % + 300 µV
3.5 % + 300 µV
4 % + 300 µV
6 % + 300 µV
7 % + 300 µV
2.5 µHz/Hz
1.5 % + 100 µV
2.0 % + 100 µV
4.0 % + 100 µV
5.0 % + 100 µV
25 µs/s + t·1000 µs/s
3 µs/s
4 µs/s
Fluke 5520A option
SC1100 & Agilent
3458A opt 002
Fluke 5520A option
SC1100
t is the time in
seconds | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 11 of 13
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 5, 7 (±)
Comments
Torque – Measuring
Equipment
(5 to 50) lbf·in
(>50 to 300) lbf·in
(25 to 100) lbf·ft
(>100 to 600) lbf·ft
0.4 lbf·in
1.8 lbf·in
2.6 lbf·ft
4.9 lbf·ft
Sturtevant-Richmont
torque tester
Snap-on torque testers
Scales & Balances3
(1 to 1000) g
(1000 to 20 000)g
Up to 25 lb
[Up to 11.3398 kg]
(25 to 50) lb
[(11.3398 to 22.6796) kg]
(50 to 200) lb
[(22.6796 to 90.7185) kg]
1 mg + 0.6R
1.1 g + 0.6R
0.1 g + 0.6R
0.3 g + 0.6R
0.7 lb + 0.6R
Class 1 weights
Class F weights
Pressure Gages
(1 to 300) psi
(10 to 1000) psi
(1000 to 10 000) psi
0.15 psi + 0.6R
0.03 % + 0.6R
8 psi + 0.6R
Fluke 718
Ametek HK-1000
Fluke 700HTP2
Force3 – Measure &
Measuring Equipment
Fixed Points
0.25 oz to 25 lbf
[7.1 gf to 11.3398 kgf]
25 lbf
50 lbf
75 lbf
100 lbf
125 lbf
150 lbf
200 lbf
210 mgf + 0.6R
0.0017 lbf + 0.6R
0.0036 lbf + 0.6R
0.0052 lbf + 0.6R
0.0067 lbf + 0.6R
0.0083 lbf + 0.6R
0.0097 lbf + 0.6R
0.012 lbf + 0.6R
Heusser Neweigh
Class F weights
Rice Lake:
1203
1207
1203, 1207
1207, 1208
1207, 1208, 1203
1207, 1208, 1203, 1204
ALL | ||
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 12 of 13
V. Thermodynamics
Parameter/Equipment
Range CMC2, 7 (±) Comments
Temperature – Measure
(-35 to 350) °C
0.79 °C
Fluke 9140 dry well
Temperature – Measuring
Equipment
0 °F
(>0 to 400) °F
(>400 to 600) °F
(>600 to 800) °F
0.5 °F
4.8 °F
5.1 °F
6.8 °F
Fluke 714
thermocouples
Relative Humidity –
Measure3
Up to 90 % RH
(90 to 98) % RH
1.9 % RH
2.5 % RH
Vaisala MI70/HMP77
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 5, 7 (±) Comments
Frequency – Measuring
Equipment
10 MHz
0.16 Hz
Efratom frequency
standard
Frequency – Measure3
1 Hz to 1.1 GHz
0.27 Hz
HP 5334B
Stopwatches3
(0 to 86 400) s/day
0.96 s/day + 0.6R
Master stopwatch
___________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC percent refers to percent of reading unless otherwise noted. | -35 to 350 °C |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2010.01) 2/14/2025 Page 13 of 13
5 L is the length in inches/mm of the unit under test , RD is the resolution in inches/mm for dimensional
calibrations, and R is the resolution of the unit under test for all other calibrations.
6
The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a
fraction of the reading plus a fixed floor specification.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 14 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AALFA - KAL Metrology Laboratory, division of AALBORG Instruments & ControlsOrangeburg, NY · ~70 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Long Island, NYBohemia, NY · ~73 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Fischer Technology, Inc. USAWindsor, CT · ~74 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - WINDSORWindsor, CT · ~74 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- AH Electronic Test Equipment Repair CenterIslip, NY · ~76 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.