JLW Instruments
14 N. Peoria Street, Suite B101, 60607, Chicago, IL, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1753.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1753.01) 4/30/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Force & Material Testing
Machines3 –
Crosshead Distance
Crosshead Speed
(1 to 24) in
(0.6 to 6) in/min
(6.0 to 80) in/min
0.012 in
(0.66 % of rdg + 0.000 89)
in/min
(0.06 % of rdg + 0.08)
in/min
High resolution
travel encoder
Pressure – Measuring
Equipment
Hydraulic Gages
Pneumatic Gages
(0 to 1000) psi
(1000 to 15 000) psi
(-14 to 0) psi
(0 to 100) psi
0.021 % + 0.1 psi
0.025 % + 0.8 psi
0.004 psi + 0.000 010x psi
0.024 psi
Deadweight
tester
Digital pressure
gages
1 This laboratory offers commercial calibration and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 In the statement of CMC, all percentages are to be read as percent of reading unless otherwise noted. In
the statement of CMC, x is the level of force at the time of calibration.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- NovamedSkokie, IL · ~20 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Florida Metrology, LLC d/b/a Acme MetrologyVilla Park, IL · ~29 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- DicksonAddison, IL · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Chicago, ILArlington Heights, IL · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- GraftelRoselle, IL · ~40 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.