Registers refreshed 2026-11-08.See refresh dates
United States

TEGAM, Inc.

10 Tegam Way, 44041, Geneva, OH, United States

Visit website
A2LA 2018.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 2018.01 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-0 to 120 Ω
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 2 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate (For Calibration of TEGAM RF Power Meters Only) DC A/D Calibration Factors for TEGAM 1830A Power Meter 10 V CS2RvSlope (Voltmeter Slope Adjust, 1.0 V Nominal) CS2RvOffset (Voltmeter Offset) – 0.0V Nominal DacSlope (Reference Source Slope Adjust 1.0 V Nominal) DacOffset (Reference Source Offset) 0.0V Nominal DacRVSlope (PGA Slope Adjust, Gain of 8, 1.0 Nominal) 1 DacRvSlope (PGA Slope Adjust, Gain of 1, 1.0 V Nominal) 0.0020 % + 28 μV 0.000 28 V/V 0.000 24 V 0.000 26 V/V 0.0004 V 0.000 28 V/V 0.000 28 V/V Using TEGAM calibration tool, tracing through Keysight 34420A Measurands are calibration coefficients for TEGAM 1830A power meter PGA: “programmable gain amplifier” Thermocouples Simulation Source & Measure T/C Alloy Types – Type B Type E (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (-250 to -200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 0) °C (0 to 350) °C (350 to 600) °C (600 to 650) °C (650 to 1000) °C 0.40 °C 0.31 °C 0.31 °C 0.24 °C 0.30 °C 0.13 °C 0.10 °C 0.10 °C 0.09 °C 0.09 °C 0.11 °C 0.11 °C Fluke 7526A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 3 of 16 Parameter/Equipment Range CMC2 (±) Comments Thermocouples Simulation Source & Measure T/C Alloy Types – (cont) Type J Type K Type N Type R Type S (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 800) °C (800 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 800) °C (800 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 120) °C (120 to 410) °C (410 to 800) °C (800 to 1300) °C (0 to 100) °C (100 to 250) °C (250 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (0 to 100) °C (100 to 250) °C (250 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1400) °C (1400 to 1600) °C (1600 to 1767) °C 0.16 °C 0.10 °C 0.10 °C 0.10 °C 0.10 °C 0.11 °C 0.18 °C 0.11 °C 0.11 °C 0.11 °C 0.14 °C 0.14 °C 0.26 °C 0.14 °C 0.13 °C 0.12 °C 0.11 °C 0.11 °C 0.11 °C 0.13 °C 0.44 °C 0.32 °C 0.31 °C 0.25 °C 0.23 °C 0.21 °C 0.25 °C 0.43 °C 0.33 °C 0.32 °C 0.26 °C 0.25 °C 0.24 °C 0.24 °C 0.28 °C Fluke 7526A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 4 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Thermocouples Simulation Source & Measure T/C Alloy Types – (cont) Type T (-250 to -200) °C (-200 to -150) °C (-150 to -100) °C (-100 to 0) °C (0 to 120) °C (120 to 200) °C (200 to 400) °C 0.44 °C 0.26 °C 0.17 °C 0.12 °C 0.10 °C 0.10 °C 0.10 °C Fluke 7526A DC Voltage –Measure (0 to 120) mV 0.0034 % rdg + 2 µV Keithley 3706A DMM PRT/RTD Resistance – Measuring Equipment & Measure (0 to 400) Ω 0.002 % rdg + 0.002 Ω Fluke 1586A DC Resistance – Generate Fixed Points 20 MΩ 10 MΩ 2 MΩ 1 MΩ 200 kΩ 180 kΩ 100 kΩ 20 kΩ 18 kΩ 10 kΩ 2 kΩ 1.8 kΩ 1 kΩ 200 Ω 180 Ω 100 Ω 20 Ω 18 Ω 10 Ω 2 Ω 1.8 Ω 34 µΩ/Ω 32 µΩ/Ω 25 µΩ/Ω 23 µΩ/Ω 11 µΩ/Ω 18 µΩ/Ω 8 µΩ/Ω 10 µΩ/Ω 26 µΩ/Ω 10 µΩ/Ω 12 µΩ/Ω 14 µΩ/Ω 9 µΩ/Ω 13 µΩ/Ω 11 µΩ/Ω 5 µΩ/Ω 18 µΩ/Ω 20 µΩ/Ω 5 µΩ/Ω 17 µΩ/Ω 18 µΩ/Ω Precision resistance standards
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 5 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments DC Resistance – Generate (cont) Fixed Points 1 Ω 200 mΩ 180 mΩ 100 mΩ 20 mΩ 18 mΩ 10 mΩ 2 mΩ 1.8 mΩ 1 mΩ 180 µΩ 0 Ω 5 µΩ/Ω 24 µΩ/Ω 38 µΩ/Ω 8 µΩ/Ω 39 µΩ/Ω 200 µΩ/Ω 13 µΩ/Ω 55 µΩ/Ω 130 µΩ/Ω 13 µΩ/Ω 310 µΩ/Ω 5 nΩ Precision resistance standards II. Electrical – RF/Microwave Parameter/Equipment Frequency CMC2, 4 (±) Comments RF Power – 1 mW Calibration Factor N Connector Terminating Mount with |S11| < 0.01 6 kHz ≤ f < 20 kHz 20 kHz ≤ f < 50 kHz 50 kHz ≤ f < 100 kHz 0.0020 mW/mW 0.0021 mW/mW 0.0024 mW/mW Impedance method, 4284A LCZ meter, 3458 AC RMS, voltmeter, 3458 or 34420A DC voltmeter RF Power – 1 mW Calibration Factor 3 N Connector 100 kHz 200 kHz 300 kHz to 2.0 GHz (2.1 to 3.6) GHz (3.7 to 4.6) GHz (4.8 to 10.0) GHz (10.2 to 11.8) GHz (12.0 to 18.0) GHz 0.62 % 0.57 % 0.54 % 0.56 % 0.58 % 0.64 % 0.68 % 0.78 % TEGAM 1505, M1130 power standards with 1806 power meter & Keysight 34420A or 3458A DMMs
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 6 of 16 Parameter/Equipment Frequency CMC2, 5 (±) Comments RF Power – 1 mW Calibration Factor3 (cont) 3.5 mm Connector 2.4 mm Connector 10 MHz 20 MHz (30 to 90) MHz (100 to 700) MHz (0.75 to 3.0) GHz (3.1 to 5.4) GHz (5.6 to 6.4) GHz (6.6 to 9.2) GHz (9.4 to 13.5) GHz (13.75 to 22.00) GHz (23.00 to 26.50) GHz (10 to 40) MHz 50 MHz (100 to 2000) MHz (2.2 to 4.6) GHz (4.8 to 10.8) GHz (11 to 12) GHz (12.2 to 13) GHz 14 GHz 15 GHz 16 GHz 17 GHz 18 GHz (19 to 21) GHz (22 to 26) GHz (27 to 29) GHz (30 to 32) GHz (33 to 39) GHz 40 GHz 41 GHz 42 GHz 43 GHz 44 GHz 45 GHz 46 GHz 47 GHz 48 GHz 49 GHz 50 GHz 1.5 % 1.3 % 1.2 % 1.1 % 1.2 % 1.3 % 1.4 % 1.5 % 1.8 % 2.3 % 3.0 % 0.81 % 0.80 % 0.87 % 1.0 % 1.2 % 1.2 % 1.3 % 1.4 % 1.4 % 1.3 % 1.4 % 1.4 % 1.4 % 1.6 % 1.6 % 1.6 % 1.9 % 2.1 % 2.1 % 1.6 % 1.7 % 2.1 % 2.5 % 2.3 % 2.2 % 2.3 % 2.7 % 2.8 % TEGAM 1135 power standards with 1806 power meter & Keysight 34420A or 3458A DMMs TEGAM M1130. 1510 power standard with 1806 power meter & Keysight 34420A or 3458A DMMs TEGAM 1510, Keysight 8487A power standard with 1806 power meter & Keysight 34420A or 3458A DMMs TEGAM 1510 with 1806 power meter & Keysight 34420A or 3458A DMMs
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 7 of 16 Parameter/Equipment Frequency CMC2, 5 (±) Comments RF Reflection S11/S22 – Linear Magnitude: Low Frequency, All Types N Connector (6 to 100) kHz 100 kHz to 50 MHz 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (2 to 8) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (8 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 0.01 lin. mag. 0.01 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0060 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0080 lin. mag. 0.009 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.0075 lin. mag. 0.008 lin. mag. 0.010 lin. mag. Keysight 4284 Agilent 4395A impedance analyzer with 87511A & 87512A test set, 85054A, 85052B, or 85056A cal kits Keysight 8510C VNA with 8515A test set & 85054A calibration kit ρ = voltage reflection coefficient Keysight 8510C VNA with 8515A test set & 85052B calibration kit
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 8 of 16 Parameter/Equipment Frequency CMC2 (±) Comments RF Reflection S11/S22 – (cont) Linear Magnitude: 3.5 mm Connector 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (2 to 8) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (8 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0060 lin. mag. 0.0060 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0060 lin. mag. 0.0060 lin. mag. 0.0060 lin. mag. Keysight 8510C VNA with 8515A test set & 85052B calibration kit ρ = voltage reflection coefficient
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 9 of 16 Parameter/Equipment Frequency CMC2 (±) Comments RF Reflection S11/S22 – (cont) Linear Magnitude: 3.5 mm Connector 2.4 mm Connectors (20 to 26.5) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (2 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (20 to 40) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0050 lin. mag. 0.0060 lin. mag. 0.0070 lin. mag. 0.0070 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.010 lin. mag. 0.015 lin. mag. 0.015 lin. mag. 0.015 lin. mag. 0.015 lin. mag. 0.015 lin. mag. 0.015 lin. mag. 0.016 lin. mag. 0.017 lin. mag. Keysight 8510C VNA with 8515A test set & 85052B calibration kit ρ = voltage reflection coefficient Keysight 8510A VNA with 8517A test set & 85056A SOLT
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 10 of 16 Parameter/Equipment Frequency CMC2 (±) Comments RF Reflection S11/S22 – (cont) Linear Magnitude: 2.4 mm Connectors Phase Angle: Low Frequency, All Types N Connector (40 to 50) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (6 to 100) kHz: ρ < 0.01 100 kHz to 50 MHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 0.019 lin. mag. 0.019 lin. mag. 0.019 lin. mag. 0.019 lin. mag. 0.019 lin. mag. 0.019 lin. mag. 0.020 lin. mag. 0.021 lin. mag. 180° 180° 17° 10° 7° 5° 4° 3° 2° 180° 10° 6° 4° 3° 2° 2° 1° Keysight 8510A VNA with 8517A test set & 85056A SOLT Keysight 4284 Keysight 4395A impedance analyzer with 87511A & 87512A Test Set, 85054A, 85052B, or 85056A cal kits Keysight 8510C VNA with 8515A test set & 85054A calibration kit ρ = voltage reflection coefficient
to 50 GHz
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 11 of 16 Parameter/Equipment Frequency CMC2 (±) Comments RF Reflection S11/S22 – (cont) Phase Angle: N Connector 3.5 mm Connector (2 to 8) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (8 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (2 to 8) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 180° 24° 9° 6° 5° 4° 3° 2° 180° 24° 9° 6° 5° 4° 3° 2° 180° 10° 5° 4° 2.5° 2° 2° 1.5° 180° 10° 5° 4° 2.5° 2° 2° 1.5° Keysight 8510C VNA with 8515A test set & 85052B calibration kit ρ = voltage reflection coefficient
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 12 of 16 Parameter/Equipment Frequency CMC2 (±) Comments RF Reflection S11/S22 – (cont) Phase Angle: 3.5 mm Connector 2.4 mm Connectors (8 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (20 to 26.5) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 45 MHz to 2 GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (2 to 20) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 180° 10° 5° 4° 3° 2.2° 2° 1.5° 180° 10° 5° 4° 3° 2.2° 2° 1.5° 180° 31° 11° 8° 5° 4° 3° 2° 180° 31° 11° 8° 5° 4° 3° 3° Keysight 8510A VNA with 8517A test set & 85056A SOLT ρ = voltage reflection coefficient
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 13 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments RF Reflection S11/S22 – (cont) Phase Angle: 2.4 mm Connectors (20 to 40) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 (40 to 50) GHz: ρ < 0.024 0.024 < ρ < 0.047 0.047 < ρ < 0.07 0.07 < ρ < 0.09 0.09 < ρ < 0.13 0.13 < ρ < 0.17 0.17 < ρ < 0.25 0.25 < ρ < 0.5 180° 41° 18° 12° 8° 7° 5° 4° 180° 48° 29° 16° 11° 9° 7° 5° Keysight 8510A VNA with 8517A test set & 85056A SOLT ρ = voltage reflection coefficient Transmission – Measure S12/S21 Low Frequency, Any Port N Connection: (0, -3, -6, -10) dB (-12, -20) dB -30 dB 100 kHz to 50 MHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz 0.12 dB 0.033 dB 0.06 dB 0.10 dB 0.055 dB 0.06 dB 0.10 dB 0.15 dB 0.06 dB 0.11 dB Keysight 4395A impedance analyzer with 87511A test set, 85054A, 85052B, or 85056A cal kits Keysight 8510C VNA with 85054A calibration kit
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 14 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments Transmission – Measure S12/S21 (cont) 3.5 mm Connection: (0, -3, - 6, -10) dB (-12, -20) dB -30 dB 2.4 mm Connection: (0, -3, -6, -10) dB (-12, -20) dB -30 dB 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 50 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 50 MHz to 2 GHz (2 to 20) GHz (20 to 40) GHz (40 to 50) GHz 50 MHz to 2 GHz (2 to 20) GHz (20 to 40) GHz (40 to 50) GHz 50 MHz to 2 GHz (2 to 20) GHz (20 to 40) GHz (40 to 50) GHz 0.03 dB 0.02 dB 0.02 dB 0.03 dB 0.035 dB 0.02 dB 0.025 dB 0.04 dB 0.04 dB 0.025 dB 0.033 dB 0.08 dB 0.025 dB 0.055 dB 0.15 dB 0.20 dB 0.032 dB 0.06 dB 0.15 dB 0.25 dB 0.06 dB 0.06 dB 0.2 dB 0.45 dB Keysight 8510C VNA with 85052B calibration kit Keysight 8510C VNA with 85056A calibration kit
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 15 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments RF Power – Measure4 (10 to 250) W (10 to 5000) W (10 to 10 000) W (100 to 10 000) W 50 Hz to 3.5 GHz 50 Hz to 1 GHz 50 Hz to 500 MHz 50 Hz to 500 MHz 50 Hz to 500 MHz 0.15 W + 0.14 % of rdg + 0.2 % of rdg · f (GHz) 0.14 W + 0.13 % of rdg + 0.2 % of rdg · f (GHz) 1.2 W + 0.10 % of rdg 1 W + 0.11 % of rdg 1 W + 0.085 % of rdg TEGAM Model 1314 calorimeter transferring from radian RD-23 wattmeter f = frequency in GHz TEGAM Model 1314 calorimeter transferring from radian RD-23 wattmeter for internal calibration where mismatch is considered separately f = frequency in GHz TEGAM Model 1315 calorimeter transferring from radian RD-23 wattmeter TEGAM Model 1316 calorimeter transferring from Zimmer LMG600 power analyzer TEGAM Model 1316 calorimeter transferring from Zimmer LMG600 power analyzer for internal calibration where mismatch is considered separately
10 to 10000 W
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2018.01) 12/23/2025 Page 16 of 16 III. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measure & Measuring Equipment (0 to 30) °C (21 to 25) °C 0.009 °C 0.01 °C AM1760 secondary SPRT RTD-002 ___________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Expressed as linear error of reported Cal Factor, reported in percentage, where the ideal Cal Factor is 100 %. Number given is the CMC of the highest uncertainty test in the frequency range. 4 The CMC claim is smaller than that of the expanded uncertainty claim for NIST as listed in the BIPM Key Comparison Database. A2LA has evaluated the laboratory’s CMC claim and has verified this information to be correct and appropriate. 5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
0 to 30 °C
17ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

10 Tegam Way, Geneva, OH, 44041, US

41.80525, -80.94762

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.