Control Company
12554 Galveston Road Suite B230, 77598, Webster, TX, United States
Visit website- Scope lines
- 7
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 1750.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | Conductivity reference solutions; Conductivity solutions; Buffer solutions | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1750.01) 01/19/2026 Page 2 of 4
II. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Digital Calipers – Fixed
Points
Outside & Depth
Inside
0.1 in
2 in
4 in
6 in
8 in
1 in
290 μin
320 μin
390 μin
490 μin
610 μin
300 μin
Gage set
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple, Type K
(-195 to -115) °C
(> -115 to -55) °C
(> -55 to 1000) °C
(> 1000 to 1300) °C
0.16 °C
0.13 °C
0.11 °C
0.14 °C
Fluke 7526A precision
process calibrator
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Barometric Pressure –
Measure
(500 to 1100) hPa or mbar
0.23 hPa or mbar
Digital barometer
Class A
Gauge & Differential
Pressure
(0 to 15) psi
(> 15 to 100) psi
(> 100 to 300) psi
0.0086 psi
0.020 psi
0.76 psi
Druck pressure
transducer
Cole Parmer pressure
transducer
Scales & Balances, Fixed
Points
100 g
200 g
300 g
0.30 mg
0.41 mg
0.89 mg
Troemner Ultra Class
weights | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1750.01) 01/19/2026 Page 3 of 4
V. Optical Quantities
Parameter/Equipment
Range
CMC2 (±)
Comments
Calibration of Light
Meters
(0 to 40) lux
(> 40 to 400) lux
(> 400 to 1000) lux
(> 1000 to 4000) lux
(> 4000 to 10 000) lux
(> 10 000 to 20 000) lux
4.3 lux
8.4 lux
19 lux
99 lux
240 lux
830 lux
Standard light meter
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Digital Thermometers &
Temperature Probes
-196 °C
(-80 to < 0) °C
(0 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
0.021 °C
0.023 °C
0.0087 °C
0.040 °C
0.051 °C
PRT thermometer
plus calibration bath
Thermistor probe
plus water bath
PRT thermometer plus
oil bath
IR Temperature –
Measuring Equipment
0 °C
35 °C
(> 35 to 100) °C
(> 100 to 200) °C
(> 200 to 350) °C
(> 350 to 500) °C
0.83 °C
0.49 °C
0.76 °C
1.1 °C
1.7 °C
2.3 °C
Liquid bath
Infrared calibrator BB
Relative Humidity –
Measuring Equipment
(10 to 80) % RH @ (18 to
28) °C
0.46 % RH
Chilled mirror
hygrometer | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1750.01) 01/19/2026 Page 4 of 4
VII. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Digital Stopwatch Timer &
Time Base Error
(0 to 10) s/24 hr
0.041 s/24 hr
Non-contact frequency
counter
Revolutions Per Minute –
Digital Tachometer
(0 to 10) rpm
(> 10 to 100) rpm
(> 100 to 1000) rpm
(> 1000 to 10 000) rpm
(> 10 000 to 100 000) rpm
0.000 73 rpm
0.0016 rpm
0.026 rpm
0.24 rpm
3.8 rpm
Pulse generator &
frequency counter
_______________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Salinity is a measure of the mass of dissolved salts (ionic constituents) in a given mass of solution and
expressed as percentage (%).
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
A2LA certificate 1750.02 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Conductivity Standards in Water and Propanol; pH Buffers in DI Water and Carbonates; Conductivity Standards In Water and Propanol; pH Buffers in DI Water and CarbonatesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1750.02) 01/19/2026 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO 17034:2016
CONTROL COMPANY
12554 Galveston Road Suite B230
Webster, TX 77598
Jenny Ren Phone: 281 400 2124
REFERENCE MATERIAL PRODUCER
Valid To: December 31, 2027 Certificate Number: 1750.02
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
Reference Material Producer for the production of the following reference materials and certified reference
materials:
Certified Reference
Material/ Artifact or
Matrix
Properties Characterized/
Concentration Ranges Uncertainty
Approach Used to
Assign Property
Values
Conductivity Standards
in Water and Propanol
(1 to 10) µS/cm
(50 to 100) µS/cm
(1000 to 1413) µS/cm
(5000 to 10 000) µS/cm
(50 000 to 100 000) µS/cm
(150 000 to 200 000) µS/cm
0.62 µS/cm
2.1 µS/cm
4.6 µS/cm
40 µS/cm
360 µS/cm
510 µS/cm
Comparison to NMI
SRM
pH Buffers in DI Water
and Carbonates
(2, 4, 7, 10) pH
0.011 pH
Comparison to NMI
SRM
Reference Material/ Artifact
or Matrix
Properties Characterized/
Concentration Ranges
Approach Used to Assign
Property Values
Conductivity Standards In Water
and Propanol
(1 to 200 000) µS/cm
Testing with calibrated probe
pH Buffers in DI Water and
Carbonates
(1 to 12) pH
Testing with calibrated probe | See scope document |
| 2 | - | Reference materialsShow page textExtracted from the scope document; tables may not line up. View scope for the original. For the reference materials to which this accreditation applies, please refer to the reference material producer’s Scope of Accreditation.
Accredited Reference Material Producer
A2LA has accredited
CONTROL COMPANY
Webster, TX
This accreditation covers the specific materials listed on the agreed upon Scope of Accreditation.
This producer meets the requirements of ISO 17034:2016 General Requirements for the
Competence of Reference Material Producers. This accreditation demonstrates technical competence
for a defined scope and the operation of a quality management system.
Presented this 19th day of January 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1750.02
Valid to December 31, 2027 | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Endress+HauserPearland, TX · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - HOUSTONHouston, TX · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technology & Calibration, Inc. dba Tech CalHouston, TX · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Troxler Electronic Laboratories, Inc.Houston, TX · ~35 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- JM Test Systems, LLC.Clute, TX · ~63 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.