M & M Metrology
254 South Military Trail, 33442, Deerfield Beach, FL, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 5352.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1100 V |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 2 of 10
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current – Generate3
Up to 220 μA
220 µA to 2.2 mA
(2.2 to 22) mA
22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20) A
20 µA/A + 6.3 nA
31 µA/A + 11 nA
31 µA/A + 96 nA
43 µA/A + 400 nA
75 µA/A + 12 µA
260 µA/A + 280 µA
990 µA/A + 270 µA
Multifunction
calibrator, amplifier
4 Wire Resistance –
Measure3
Up to 10 Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
12 µΩ/Ω + 160 µΩ
16 µΩ/Ω + 1 mΩ
17 µΩ/Ω + 390 µΩ
17 µΩ/Ω + 3.9 mΩ
17 µΩ/Ω + 38 mΩ
20 µΩ/Ω + 3.1 Ω
81 µΩ/Ω + 63 Ω
1.2 mΩ/Ω + 650 Ω
12 mΩ/Ω + 64 kΩ
Digital multimeter
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
0.88 µΩ/Ω + 0.01 Ω
1.3 µΩ/Ω + 0.015 Ω
3.7 µΩ/Ω + 0.015 Ω
8.2 µΩ/Ω + 0.019 Ω
19 µΩ/Ω + 0.016 Ω
8.2 µΩ/Ω + 0.19 Ω
24 µΩ/Ω + 0.059 Ω
8.5 µΩ/Ω + 0.046 Ω
24 µΩ/Ω + 0.59 Ω
18 µΩ/Ω + 8.7 Ω
28 µΩ/Ω + 5.4 Ω
38 µΩ/Ω + 120 Ω
120 µΩ/Ω + 91 Ω
220 µΩ/Ω + 1.4 kΩ
500 µΩ/Ω + 0.70 kΩ
3.0 mΩ/Ω + 21 kΩ
15 mΩ/Ω + 53 kΩ
Multifunction
calibrator | to 20 A |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 3 of 10
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate3
(cont)
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
51 µΩ
100 µΩ
180 µΩ
250 µΩ
460 µΩ
1.0 mΩ
1.9 mΩ
6.8 mΩ
13 mΩ
67 mΩ
130 mΩ
880 mΩ
1.7 Ω
14 Ω
35 Ω
420 Ω
940 Ω
11 kΩ
Multifunction calibrator
Capacitance3 – Generate
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(.33 to 1.1) μF
(1.1 to 3.3) μF
(3.3 to 11) μF
(11 to 33) μF
(33 to 110) μF
(110 to 330) μF
(.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.075 % + 10 pF
0.17 % + 9.8 pF
0.35 % + 7.6 pF
0.21 % + 6.8 pF
0.24 % + 3.6 pF
0.82 % + 9.9 pF
0.24 % + 41 pF
0.20 % + 750 pF
0.21 % + 1.9 nF
0.20 % + 7.5 nF
0.37 % + 16 nF
0.41 % + 60 nF
0.41 % + 170 nF
0.41 % + 0.56 µF
0.42 % + 1.2 µF
0.42 % + 4.0 µF
0.73 % + 7.8 µF
1.1 % + 18 µF
Multifunction calibrator | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 4 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure3
Up to 10 mV
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
1 to 2 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
3.1 µV/V + 0.22 µV
1.4 µV/V + 0.22 µV
3.1 µV/V + 0.22 µV
28 µV/V + 0.26 µV
0.69 mV/V + 0.26 µV
29 mV/V + 0.24 µV
62 µV/V + 2.3 µV
57 µV/V + 3.2 µV
140 µV/V + 2.6 µV
330 µV/V + 1.7 µV
0.92 mV/V + 0.76 µV
3.4 mV/V + 2.2 µV
12 mV/V + 0.67 µV
46 mV/V + 0.65 µV
51 µV/V + 42 µV
66 µV/V + 18 µV
150 µV/V + 13 µV
340 µV/V + 7.9 µV
0.92 mV/V + 0.0032 mV
3.5 mV/V + 0.021 mV
12 mV/V + 0.0064 mV
17 mV/V + 0.0043 mV
50 µV/V + 440 µV
66 µV/V + 180 µV
150 µV/V + 130 µV
340 µV/V + 77 µV
0.92 mV/V + 0.032 mV
3.5 mV/V + 0.21 mV
12 mV/V + 0.063 mV
17 mV/V + 0.044 mV
0.20 mV/V + 3.1 mV
0.22 mV/V + 1.1 mV
0.22 mV/V + 1.1 mV
0.40 mV/V + 0.68 mV
1.4 mV/V + 0.22 mV
4.6 mV/V + 1.6 mV
17 mV/V + 0.42 mV
0.44 mV/V + 21 mV
0.46 mV/V + 6.0 mV
0.69 mV/V + 4.1 mV
1.4 mV/V + 2.1 mV
3.5 mV/V + 1.1 mV
Digital multimeter | to 0.01 V |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 5 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate3
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
8.5 µV/V + 7.5 µV
1.2 µV/V + 7.5 µV
0.94 µV/V + 7.5 µV
5.9 µV/V + 7.5 µV
33 µV/V + 8.3 µV
100 µV/V + 12 µV
100 µV/V + 21 µV
370 µV/V + 21 µV
81 µV/V + 7.5 µV
13 µV/V + 7.5 µV
10 µV/V + 7.5 µV
59 µV/V + 7.5 µV
270 µV/V + 7.9 µV
690 µ V/V + 11 µV
780 µV/V + 21 µV
2.0 mV/V + 20 µV
180 µV/V + 15 µV
50 µV/V + 13 µV
27 µV/V + 11 µV
85 µV/V + 10 µV
250 µV/V + 17 µV
590 µV/V + 18 µV
1.3 mV/V + 21 mV
2.6 mV/V + 24 mV
230 µV/V + 18 µV
85 µV/V + 13 µV
36 µV/V + 15 µV
58 µV/V + 23 µV
76 µV/V + 23 µV
320 µV/V + 47 µV
690 µV/V + 100 µV
1.6 mV/V + 170 µV
190 µV/V + 1.5 mV
66 µV/V + 690 µV
25 µV/V + 550 µV
49 µV/V + 510 µV
64 µV/V + 520 µV
230 µV/V + 510 µV
940 µV/V + 1.4 µV
1.4 mV/V + 1.9 µV
Multifunction calibrator | to 2.2 V |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 6 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate3
(cont)
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
190 µV/V + 15 mV
41 µV/V + 19 mV
36 µV/V + 4.8 mV
9 µV/V + 3.0 mV
130 µV/V + 6.1 mV
870 µV/V + 8.3 mV
4.4 mV/V + 9.4 mV
7.9 mV/V + 19 mV
280 µV/V + 22 mV
61 µV/V + 13 mV
Multifunction
calibrator
AC Current – Generate3
Up to 220 μA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
190 µA/A + 0.016 µA
100 µA/A + 0.016 µA
58 µA/A + 0.014 µA
220 µA/A + 0.016 µA
820 µA/A + 0.073 µA
200 µA/A + 0.13 µA
300 µA/A + 0.056 µA
74 µA/A + 0.083 µA
160 µA/A + 0.11 µA
910 µA/A + 0.51 µA
170 µA/A + 2.2 µA
120 µA/A + 1.1 µA
74 µA/A + 0.83 µA
170 µA/A + 0.77 µA
960 µA/A + 3.6 µA
170 µA/A + 23 µA
120 µA/A + 11 µA
75 µA/A + 8.0 µA
160 µA/A + 9.7 µA
1.1 mA/A + 7.1 µA
200 µA/A + 110 µA
410 µA/A + 91 µA
7.0 µA/A + 29 µA
Multifunction
calibrator | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 7 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate3
(cont)
(2.2 to 11) A
(3 to 20.5) A
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 100) Hz
100 Hz to 1 kHz
460 µA/A + 21 µA
950 µA/A + 43 µA
3.6 mA/A + 43 µA
1.7 mA/A + 710 µA
10 mA/A + 490 µA
Multifunction
calibrator
AC Current – Measure3
Up to 100 µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
560 µA/A + 2.1 µA
80 mA/A + 2.1 mA
13 mA/A + 2.1 mA
13 mA/A + 3.8 mA
3.3 mA/A + 1.8 µA
690 µA/A + 2.0 µA
120 µA/A + 2.1 µA
31 µA/A + 2.1 µA
120 µA/A + 2.1 µA
3.2 mA/A + 1.8 µA
4.6 mA/A + 2.3 µA
4.5 mA/A + 1.0 µA
1.6 mA/A + 2.0 µA
490 µA + 2.7 µA
170 µA + 2.9 µA
490 µA + 2.7 µA
4.4 mA/A + 2.4 µA
5.3 mA/A + 13 µA
4.6 mA/A + 6.0 µA
1.6 mA/A + 13 µA
540 µA/A + 19 µA
200 µA/A + 21 µA
540 µA/A + 19 µA
4.4 mA/A + 21 µA
5.3 mA/A + 130 µA
4.6 mA/A + 60 µA
1.7 mA/A + 120 µA
780 µA/A + 170 µA
1.0 mA/A + 160 µA
3.4 mA/A + 76 µA
11 mA/A + 98 µA
Digital multimeter | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 8 of 10
II. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Pressure Gages3
(50 to 1000) psig
(500 to 10 000) psig
0.0024 % rdg + 0.000 16 psi
0.0025 % rdg + 0.0015 psi
Dead weight tester
Vacuum Gages3
(0 to 30) inHg
0.17 % + 0.025 inHg
Mensor display &
modules
Torque Analyzers &
Transducers3
8 oz∙in to 2000 lb∙ft
0.012 % rdg + 0.024 oz∙in
Class 6 weights, test
bars & wheels
Torque Wrenches,
Watches & Drivers
3
(0.15 to 9) lbf∙in
(1.5 to 90) lbf∙in
(20 to 200) lbf∙in
(10 to 100) lbf∙ft
(5 to 50) ozf∙in
(10 to 100) ozf∙in
(5 to 50) lbf∙in
(30 to 400) lbf∙in
(80 to 1000) lbf∙in
(20 to 250) lbf∙ft
(60 to 600) lbf∙ft
(200 to 2000) lbf∙ft
0.0006 % rdg + 0.53 lbf∙in
0.0007 % rdg + 0.53 lbf∙in
0.29 % rdg + 0.012 lbf∙in
0.28 % rdg + 0.27 lbf∙in
0.26 % rdg + 0.000 96 ozf∙in
0.53 % rdg + 0.0031 ozf∙in
0.26 % rdg + 0.015 lbf∙in
0.29 % rdg + 0.0049 lbf∙in
0.29 % rdg + 0.017 lbf∙in
0.29 % rdg + 0.080 lbf∙ft
0.29 % rdg + 0.036 lbf∙ft
0.29 % rdg + 0.010 lbf∙ft
Torque analyzers
Cable Tension
Measurement
(30 to 600) lbf
(200 to 2000) lbf
0.29 % rdg + 0.049 lbf
0.29 % rdg + 0.019 lbf
Multitest analyzer
Force Gages & Load
Cells3
1/32 ozf to 10 lbf
(5 to 500) lbf
0.012 % rdg
0.01 % rdg
Class 6 weights | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 9 of 10
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature3 –
Measure & Measuring
Equipment
(-197 to -80) °C
(> -80 to -38.834) °C
(> -38.834 to 0.010) °C
(> 0.010 to 156.599) °C
(> 156.599 to 231.928) °C
(> 231.928 to 419.527) °C
(> 419.527 to 660.323) °C
0.012 °C
0.012 °C
0.011 °C
0.0092 °C
0.011 °C
0.014 °C
0.024 °C
PRTs
IR Thermometers3
(35 to 550) °C
0.25 % rdg + 0.19 °C
Blackbody
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Frequency – Measure3
10 MHz
100 Hz to 225 MHz
10 Hz to 26.5 GHz
35 µHz
0.83 nHz/Hz + 0.73 µHz
0.19 pHz/Hz + 9.8 Hz
Truetime time &
frequency receiver
Frequency counter
Frequency – Generate3
1 Hz to 2 MHz
2 MHz to 6 GHz
(6 to 26.5) GHz
2.3 µHz/Hz
0.023 nHz/Hz + 0.36 µHz
0.014 nHz/Hz + 0.017 nHz
Truetime time &
frequency receiver,
frequency generator
______________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5352.01) 08/07/2024 Page 10 of 10
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 11 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Trescal, Inc. - Miami, FLBoca Raton, FL · ~5 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - POMPANO BEACHPompano Beach, FL · ~9 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Kimball ElectronicHialeah, FL · ~58 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- FLORIDA METROLOGYPort St. Lucie, FL · ~111 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - MELBOURNEMelbourne, FL · ~202 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.