2086 Hwy 93 N., Suite 130, 59875, Victor, MT, United States

Visit website
A2LA 5267.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 5267.01 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5267.01) 8/21/2025 Page 2 of 6 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current – Generate (0 to 330) µA 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3.0) A (3.0 to 11) A 0.015 % + 0.02 µA 0.010 % + 0.05 µA 0.010 % + 0.25 µA 0.010 % + 2.5 µA 0.020 % + 40 µA 0.038 % + 40 µA 0.050 % + 500 µA Fluke 5522A Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ 40 µΩ/Ω + 0.01 Ω 30 µΩ/Ω + 0.015 Ω 28 µΩ/Ω + 0.015 Ω 28 µΩ/Ω + 0.02 Ω 28 µΩ/Ω + 0.02 Ω 28 µΩ/Ω + 0.2 Ω 28 µΩ/Ω + 0.1 Ω 28 µΩ/Ω + 1 Ω 28 µΩ/Ω + 1 Ω 32 µΩ/Ω + 10 Ω 32 µΩ/Ω + 10 Ω 60 µΩ/Ω + 150 Ω 0.013 % + 250 Ω 0.025 % + 2.5 kΩ 0.050 % + 3 kΩ Fluke 5522A Parameter/Equipment Frequency CMC2, 7 (±) Comments AC Voltage – Generate 33 mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.080 % + 6 µV 0.015 % + 6 µV 0.020 % + 6 µV 0.10 % + 6 µV 0.35 % + 12 µV 0.80 % + 50 µV 0.030 % + 8 µV 0.015 % + 8 µV 0.016 % + 8 µV 0.035 % + 8 µV 0.080 % + 32 µV 0.20 % + 70 µV Fluke 5522A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5267.01) 8/21/2025 Page 3 of 6 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Generate (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.030 % + 50 µV 0.015 % + 60 µV 0.019 % + 60 µV 0.030 % + 50 µV 0.070 % + 130 µV 0.24 % + 600 µV 0.030 % + 650 µV 0.015 % + 600 µV 0.024 % + 600 µV 0.035 % + 600 µV 0.090 % + 1.6 mV 0.019 % + 2 mV 0.020 % + 6 mV 0.025 % + 6 mV 0.030 % + 6 mV 0.20 % + 50 mV 0.030 % + 10 mV 0.025 % + 10 mV 0.030 % + 10 mV Fluke 5522A AC Current – Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.20 % + 0.1 µA 0.15 % + 0.1 µA 0.13 % + 0.1 µA 0.30 % + 0.15 µA 0.80 % + 0.2 µA 1.6 % + 0.4 µA 0.20 % + 0.15 µA 0.13 % + 0.15 µA 0.10 % + 0.15 µA 0.20 % + 0.2 µA 0.50 % + 0.3 µA 1.0 % + 0.6 µA 0.18 % + 2 µA 0.090 % + 2 µA 0.040 % + 2 µA 0.080 % + 2 µA 0.20 % + 3 µA 0.40 % + 4 µA Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5267.01) 8/21/2025 Page 4 of 6 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate (cont) (33 to 330) mA (0.33 to 1.1) A (1.1 to 3.0) A (3 to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.18 % + 20 µA 0.090 % + 20 µA 0.040 % + 20 µA 0.10 % + 50 µA 0.20 % + 100 µA 0.40 % + 200 µA 0.18 % + 100 µA 0.050 % + 100 µA 0.60 % + 1 mA 2.5 % + 5 mA 0.18 % + 100 µA 0.060 % + 100 µA 0.60 % + 1 mA 2.5 % + 5 mA 0.06 % + 2 mA 0.10 % + 2 mA 3.0 % + 2 mA Fluke 5522A Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance – Generate (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF 0.50 % + 0.01 nF 0.50 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.03 nF 0.25 % + 1 nF 0.25 % + 3 nF 0.25 % + 10 nF 0.40 % + 30 nF 0.45 % + 100 nF 0.45 % + 300 nF Fluke 5522A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5267.01) 8/21/2025 Page 5 of 6 Parameter/Equipment Range CMC2 (±) Comments Thermocouple Simulation – Type K (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C 0.18 °C 0.16 °C 0.26 °C Fluke 5522A III. Mechanical Parameter/Equipment Range CMC2, 3, 4, 5 (±) Comments Pressure – Measuring Equipment (0 to 30) psi (0 to 300) psi (0 to 1000) psi (0 to 3000) psi (0 to 5000) psi (0 to 10 000) psi 0.018 psi 0.37 psi 0.28 psi 0.84 psi 1.3 psi 2.6 psi Reference gauges Vacuum – Measuring Equipment (0 to 15) psig 0.021 psi Reference gauges Torque Tools 4-50 lbf·in 30-400 lbf·in 80-1000 lbf·in 20-250 lbf·ft 60-600 lbf·ft 0.66 % 0.44 % 0.27 % 0.38 % 0.73 % Snap on VersaTest system Cable Tensiometers Up to 300 lbf 0.46 % Master load cells – tension IV. Time & Frequency Parameter/Equipment Range CMC2, 3, 4 (±) Comments Frequency – Measuring Equipment 0.01 Hz to 120 kHz 0.000 25 % + 5 µHz Fluke 5522A ____________________________________________ 1 This laboratory offers commercial calibration service.
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5267.01) 8/21/2025 Page 6 of 6 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 In the statement of CMC, psi is to be read as pounds per square inch. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2086 Hwy 93 N., Suite 130, Victor, MT, 59875, US

46.41482, -114.14940

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.