PinnaCal
2086 Hwy 93 N., Suite 130, 59875, Victor, MT, United States
Visit website- Scope lines
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 5267.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5267.01) 8/21/2025 Page 2 of 6
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Current – Generate
(0 to 330) µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3.0) A
(3.0 to 11) A
0.015 % + 0.02 µA
0.010 % + 0.05 µA
0.010 % + 0.25 µA
0.010 % + 2.5 µA
0.020 % + 40 µA
0.038 % + 40 µA
0.050 % + 500 µA
Fluke 5522A
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
40 µΩ/Ω + 0.01 Ω
30 µΩ/Ω + 0.015 Ω
28 µΩ/Ω + 0.015 Ω
28 µΩ/Ω + 0.02 Ω
28 µΩ/Ω + 0.02 Ω
28 µΩ/Ω + 0.2 Ω
28 µΩ/Ω + 0.1 Ω
28 µΩ/Ω + 1 Ω
28 µΩ/Ω + 1 Ω
32 µΩ/Ω + 10 Ω
32 µΩ/Ω + 10 Ω
60 µΩ/Ω + 150 Ω
0.013 % + 250 Ω
0.025 % + 2.5 kΩ
0.050 % + 3 kΩ
Fluke 5522A
Parameter/Equipment
Frequency CMC2, 7 (±) Comments
AC Voltage – Generate
33 mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.080 % + 6 µV
0.015 % + 6 µV
0.020 % + 6 µV
0.10 % + 6 µV
0.35 % + 12 µV
0.80 % + 50 µV
0.030 % + 8 µV
0.015 % + 8 µV
0.016 % + 8 µV
0.035 % + 8 µV
0.080 % + 32 µV
0.20 % + 70 µV
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5267.01) 8/21/2025 Page 3 of 6
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage – Generate
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.030 % + 50 µV
0.015 % + 60 µV
0.019 % + 60 µV
0.030 % + 50 µV
0.070 % + 130 µV
0.24 % + 600 µV
0.030 % + 650 µV
0.015 % + 600 µV
0.024 % + 600 µV
0.035 % + 600 µV
0.090 % + 1.6 mV
0.019 % + 2 mV
0.020 % + 6 mV
0.025 % + 6 mV
0.030 % + 6 mV
0.20 % + 50 mV
0.030 % + 10 mV
0.025 % + 10 mV
0.030 % + 10 mV
Fluke 5522A
AC Current – Generate
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.20 % + 0.1 µA
0.15 % + 0.1 µA
0.13 % + 0.1 µA
0.30 % + 0.15 µA
0.80 % + 0.2 µA
1.6 % + 0.4 µA
0.20 % + 0.15 µA
0.13 % + 0.15 µA
0.10 % + 0.15 µA
0.20 % + 0.2 µA
0.50 % + 0.3 µA
1.0 % + 0.6 µA
0.18 % + 2 µA
0.090 % + 2 µA
0.040 % + 2 µA
0.080 % + 2 µA
0.20 % + 3 µA
0.40 % + 4 µA
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5267.01) 8/21/2025 Page 4 of 6
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Current – Generate
(cont)
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3.0) A
(3 to 11) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.18 % + 20 µA
0.090 % + 20 µA
0.040 % + 20 µA
0.10 % + 50 µA
0.20 % + 100 µA
0.40 % + 200 µA
0.18 % + 100 µA
0.050 % + 100 µA
0.60 % + 1 mA
2.5 % + 5 mA
0.18 % + 100 µA
0.060 % + 100 µA
0.60 % + 1 mA
2.5 % + 5 mA
0.06 % + 2 mA
0.10 % + 2 mA
3.0 % + 2 mA
Fluke 5522A
Parameter/Equipment
Range CMC2, 7 (±) Comments
Capacitance – Generate
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
0.50 % + 0.01 nF
0.50 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.03 nF
0.25 % + 1 nF
0.25 % + 3 nF
0.25 % + 10 nF
0.40 % + 30 nF
0.45 % + 100 nF
0.45 % + 300 nF
Fluke 5522A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5267.01) 8/21/2025 Page 5 of 6
Parameter/Equipment
Range CMC2 (±) Comments
Thermocouple Simulation
– Type K
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
0.18 °C
0.16 °C
0.26 °C
Fluke 5522A
III. Mechanical
Parameter/Equipment
Range CMC2, 3, 4, 5 (±) Comments
Pressure – Measuring
Equipment
(0 to 30) psi
(0 to 300) psi
(0 to 1000) psi
(0 to 3000) psi
(0 to 5000) psi
(0 to 10 000) psi
0.018 psi
0.37 psi
0.28 psi
0.84 psi
1.3 psi
2.6 psi
Reference gauges
Vacuum – Measuring
Equipment
(0 to 15) psig
0.021 psi
Reference gauges
Torque Tools
4-50 lbf·in
30-400 lbf·in
80-1000 lbf·in
20-250 lbf·ft
60-600 lbf·ft
0.66 %
0.44 %
0.27 %
0.38 %
0.73 %
Snap on VersaTest
system
Cable Tensiometers
Up to 300 lbf
0.46 %
Master load cells –
tension
IV. Time & Frequency
Parameter/Equipment
Range CMC2, 3, 4 (±) Comments
Frequency – Measuring
Equipment
0.01 Hz to 120 kHz
0.000 25 % + 5 µHz
Fluke 5522A
____________________________________________
1 This laboratory offers commercial calibration service. | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5267.01) 8/21/2025 Page 6 of 6
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 In the statement of CMC, psi is to be read as pounds per square inch.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured
value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range
or as a percent or fraction of the reading plus a fixed floor specification. | ||
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Energy Northwest StandardsRichland, WA · ~394 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cascade Engineering ServicesRedmond, WA · ~617 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~620 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sensor CalibrationsKaysville, UT · ~624 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Global Calibration ServicesTukwila, WA · ~626 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994