Energy Northwest Standards

Richland, WA, United States

Visit website
A2LA 2724.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
27
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 27 scope lines.

A2LA certificate 2724.01 · 27 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2-Calibration gases: Ethane; Pentane; Methane; Carbon monoxide; Carbon dioxide; Hydrogen; Hydrogen sulfide; Oxygen; Sulfur dioxide
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 2 of 26 Parameter/Equipment Range CMC2, 6 (±) Comments Gas Detection Equipment – C2H6 C5H12 CH4 CO CO 2 H H 2S O2 SO 2 0.005 % 0.35 % 1 % 1.45 % 2.5 % 0.001 % 0.006 % 0.01 % 0.2 % 2.5 % 0.05 % 0.1 % 5 % 10 % 0.01 % 2 % 0.0020 % 0.0025 % 0.1 % 0.4 % 5 % 15 % 19 % 20 % 20.9 % 0.001 % 2.2 % 2.0 % 7 % 4.8 % 2.0 % 5.1 % 5.2 % 1.7 % 2.1 % 3.2 % 2.6 % 2.5 % 2.4 % 2.2 % 5.3 % 4.8 % 11 % 2.6 % 2.5 % 15 % 3.2 % 0.54 % 0.63 % 2.5 % 2.4 % 1.1 % Calibration gases: Ethane Pentane Methane Carbon monoxide Carbon dioxide Hydrogen Hydrogen sulfide Oxygen Sulfur dioxide
See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 3 of 26 III. Dimensional Parameter/Equipment Range CMC2, 6 (±) Comments UMM, SupermicrometerTM Up to 11.5 in (10 + 0.7L) µin Gage blocks Bore Micrometer (Intramic) (0.10 to 6.5) in 40 µin + 0.6R Ring gage Calipers3 Up to 40 in (20 + 7L) µin + 0.6R Gage blocks Cylindrical Square – Squareness Up to 12 in 24 µin Federal comparator 232, surface plate Dial Indicator3 (0.01 to 2) in 170 µin Dial indicator checker Length Standards Up to 50 in (10 + 2.0L) µin Laser measurement machine (LMM) Feeler Gages Up to 0.06 in 0.1 % IV + 20 µin Gage blocks, or LMM & gage blocks Height Gages Up to 48 in 61 µin + 9.6 µin/in Gage blocks, federal comparator 232
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 4 of 26 Parameter/Equipment Range CMC2, 6, 9 (±) Comments Micrometers3 – Inside Outside Depth Up to 1 in (1 to 4) in (4 to 6) in (6 to 24) in (24 to 36) in Up to 36 in Up to 12 in 11 µin + 0.6R 26 µin + 0.6R 37 µin + 0.6R 85 µin + 0.6R 120 µin + 0.6R 12 µin/in + 0.6R 12 µin/in + 0.6R Gage blocks, LMM Stage Micrometer Standard (0.004 to 2) in 20 µin + 10 µin/in LMM/Agilent 5519A laser Optical Comparator3 – Length Magnification, (Only for Overlay & Lens Systems) Angle Up to 11 in 10× to 100× Up to 45° 100 µin 0.6M 0.033° Gage blocks, magnification balls M is resolution of the overlay Outside Diameter – Pins/Plugs Spheres/Balls Up to 10 in Up to 6 in 15 µin + 3 µin/in 15 µin + 3 µin/in Pratt & Whitney Supermic TM Protractors Up to 90° 0.01° Sine plate, gage blocks, cylindrical square Paint Coat Thickness – Thin Film Shims Paint Thickness Gauge (0.001 to 0.060) in 0.1 % IV + 20 µin 100 µin + 0.6R LMM, gage blocks Calibrated shims Roughness3 – Measure Measuring Equipment (< 1 to 200) µin Ra 38, 120 µin Ra 2 % IV + 2.0 µin Ra 1 % IV + 2.0 µin Ra Roughness tester Roughness standards
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 5 of 26 Parameter/Equipment Range CMC2, 6 (±) Comments Ultrasonic Thickness Gages Up to 5 in 100 µin + 0.6R LMM, gage blocks Rulers3 (6 to 72) in 0.0008 in Keysight 5519B Sine Plate, Sine Bar, Fixed Points 5 in 10 in 20 in 190 µin 160 µin 450 µin Angle blocks, gage blocks, federal comparator 232 Levels – Digital Bubble 120 in 96 in 0.25° 0.6R Sine plate, gage blocks Tape Measure Up to 300 ft 0.01 % + 0.6R LMM Flatness3 (2 to 6) in 6 µin Optical flat Surface Plate3 (Flatness Only) 72 in × 240 in Up to 161 in Diagonal Length 100 µin 120 µin Autocollimator Hamar laser system Thread Rings Up to 1.5 in (1.5 to 4) in (4 to 6) in Minor Diameter 220 µin 270 µin 320 µin 200 µin Master thread plugs Plain pins/plugs, bore plugs, optical comparator Thread Wires (4 to 80) TPI 14 µin LMM, Pratt & Whitney Supermic TM, gage blocks Thread Plugs (0.1 to 4) in (4 to 80) TPI 75 µin 75 µin Pratt & Whitney SupermicTM, gage blocks, master thread wires
to 5 in
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 6 of 26 Parameter/Equipment Range CMC2 (±) Comments Ring Gages (0.25 to 8.0) in 15 µin + 2 µin/in Pratt & Whitney SupermicTM, gage blocks, master ring gages IV. Electrical – DC/Low Frequency Parameter/Equipment Range4 CMC2, 10 (±) Comments DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 100.0 mV 1.0 V 10.0 V 100.0 V 1000.0 V 7 µV/V + 0.5 µV 4 µV/V + 0.8 µV 3 µV/V + 3 µV 3 µV/V + 5 µV 4 µV/V + 50 µV 6 µV/V + 500 µV 0.9 µV/V 0.8 µV/V 0.75 µV/V 0.8 µV/V 0.9 µV/V Fluke 5730A Fluke 732A array Fluke 732A, 752A DC Voltage3 – Measure (0 to 120) mV (0.1 to 1.2) V (1.0 to 12) V (10 to 120) V (100 to 1050) V 10.00 V (0.5 to 10) kV (10 to 100) kV 5 µV/V + 1 µV 4 µV/V + 1 µV 4 µV/V + 2 µV 6 µV/V + 30 µV 18 µV/V + 100 µV 1.0 µV/V 0.04 % IV + 0.03 V 0.075 % IV + 0.3 V Agilent 3458A Fluke 732A array Vitrek 4700A w/ HVL- 100
0.25 to 8 in
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 7 of 26 Parameter/Equipment Range4 CMC2, 6, 10 (±) Comments DC Current3 – Measure (2 to 20) A (10 to 100) A (30 to 300) A (12 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 1.2) A 0.01 % IV 0.05 % IV 0.1 % IV 20 µA/A + 800 pA 20 µA/A + 5.0 nA 20 µA/A + 50 nA 35 µA/A + 500 nA 0.011 % IV + 10 µA Fluke Y5020, HP 3458A Guildline 9211A, Agilent 3458A Agilent 3458A DC Current3 – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.0 to 11) A (10 to 100) A 42 µA/A + 7 nA 35 µA/A + 8 nA 35 µA/A + 50 nA 45 µA/A + 0.8 µA 70 µA/A + 15 µA 340 µA/A + 480 µA 0.10 % Fluke 5730A Fluke 5730A w/ Fluke 5725A Guildline 9211A, Agilent 3458A, Valhalla 2555A Resistance – Ratio Measurement 1:1 (0.1 Ω to 10 kΩ) 0.1:1 to 10:1 (0.1 Ω to 10 kΩ) 100:1 (10 kΩ to 100 MΩ) 1.0 parts in 106 1.4 parts in 106 2.0 parts in 10 6 MI 6010, MI 6000 w/ MI 6011 extender Resistance3 – Measure (0.0 to 12) Ω (10 to 120) Ω (0.10 to 1.2) kΩ (1.0 to 12) kΩ (10 to 120) kΩ (0.10 to 1.2) MΩ (1.0 to 12) MΩ (10 to 120) MΩ 15 µΩ/Ω + 50 µΩ 12 µΩ/Ω + 500 µΩ 10 µΩ/Ω + 500 µΩ 10 µΩ/Ω + 5 mΩ 10 µΩ/Ω + 50 mΩ 15 µΩ/Ω + 2 Ω 50 µΩ/Ω + 100 Ω 0.05 % IV + 1000 Ω Agilent 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 8 of 26 Parameter/Equipment Range4 CMC2, 6, 10 (±) Comments Resistance3 – Generate 10 000.00 Ω 1.0 Ω 1.0 Ω (Nominal) 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1.0 MΩ 1.9 MΩ 10.0 MΩ 19.0 MΩ 100.0 MΩ 0.5 µΩ/Ω 0.5 µΩ/Ω 95 µΩ/Ω 95 µΩ/Ω 25 µΩ/Ω 25 µΩ/Ω 11 µΩ/Ω 11 µΩ/Ω 7.2 µΩ/Ω 7.2 µΩ/Ω 7 µΩ/Ω 7 µΩ/Ω 8 µΩ/Ω 10 µΩ/Ω 14 µΩ/Ω 17 µΩ/Ω 37 µΩ/Ω 47 µΩ/Ω 110 µΩ/Ω ESI SR-104 Leeds & Northrup 4210 Fluke 5730A Low Resistance (Earth Resistance) – Generate 100 mΩ to 4.99 Ω (5 to 29.9) Ω (30 to 199.9) Ω (200 to 499.9) Ω 500 Ω to1.999 kΩ (2 to 4.99) kΩ (5 to 10) kΩ 0.3 % + 0.01 Ω 0.2 % + 0.01 Ω 0.2 % + 0.01 Ω 0.2 % + 0.01 Ω 0.2 % 0.2 % 0.2 % Fluke 5320A High Resistance (Insulation Resistance – Generate) (10 to 39.99) kΩ (40 to 99.99) kΩ (100 to 199.99) kΩ (200 to 999.99) kΩ (1 to 9.999) MΩ (10 to 999.9) MΩ (1 to 10.0) GΩ 100 GΩ 0.2 % 0.2 % 0.2 % 0.2 % 0.3 % 0.5 % 1.0 % 3.0 % Fluke 5320A High Resistance (Insulation Resistance) – Generate with R Multiplier (0.35 to 99.99) GΩ (100 to 999.9) GΩ (1 to 10) TΩ 1.0 % + r 2.0 % + r 3.0 % + r Fluke 5320A r is the uncertainty of resistor to be multiplied by 1000.
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 9 of 26 Parameter/Equipment Range4 CMC2, 10 (±) Comments Ground Bond Resistance – Decade Generate, Fixed Points 25 mΩ 50 mΩ 100 mΩ 330 mΩ 500 mΩ 1 Ω 1.8 Ω 5.0 Ω 10.0 Ω 18.0 Ω 50.0 Ω 100 Ω 180 Ω 500 Ω 1 kΩ 1.8 kΩ 5 mΩ 5 mΩ 5 mΩ 7 mΩ 8 mΩ 10 mΩ 18 mΩ 30 mΩ 60 mΩ 100 mΩ 300 mΩ 500 mΩ 1 Ω 2.5 Ω 5 Ω 10 Ω Fluke 5320A Parameter/Range4 Frequency CMC2, 10 (±) Comments AC Voltage3 – Generate (0 to 2.2) mV (2.0 to 22) mV (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 270 µV/V + 5 µV 110 µV/V + 5 µV 90 µV/V + 5 µV 230 µV/V + 5 µV 540 µV/V + 6 µV 1200 µV/V + 12 µV 1500 µV/V + 25 µV 3100 µV/V + 25 µV 270 µV/V + 5 µV 110 µV/V + 5 µV 90 µV/V + 5 µV 230 µV/V + 5 µV 540 µV/V + 6 µV 1200 µV/V + 12 µV 1500 µV/V + 25 µV 3100 µV/V + 25 µV Fluke 5730A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 10 of 26 Parameter/Range4 Frequency CMC2, 10 (±) Comments AC Voltage3 – Generate (cont) (20 to 220) mV (0.20 to 2.2) V (2.0 to 22) V (20 to 220) V (200 to 250) V 1100 V (200 to 1100) V (200 to 750) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz (50 to 1000) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 270 µV/V + 15 µV 110 µV/V + 8 µV 66 µV/V + 8 µV 140 µV/V + 8 µV 380 µV/V + 20 µV 700 µV/V + 25 µV 1500 µV/V + 30 µV 2900 µV/V + 60 µV 270 µV/V + 50 µV 100 µV/V + 20 µV 46 µV/V + 10 µV 77 µV/V + 12 µV 97 µV/V + 40 µV 370 µV/V + 100 µV 1100 µV/V + 250 µV 1800 µV/V + 400 µV 270 µV/V + 500 µV 100 µV/V + 200 µV 46 µV/V + 70 µV 77 µV/V + 120 µV 97 µV/V + 250 µV 290 µV/V + 800 µV 1100 µV/V + 2500 µV 1600 µV/V + 4000 µV 270 µV/V + 5 mV 100 µV/V + 2 mV 60 µV/V + 0.7 mV 95 µV/V + 1.2 mV 170 µV/V + 3 mV 1000 µV/V + 20 mV 5200 µV/V + 50 mV 9000 µV/V + 100 mV 320 µV/V + 20 mV 75 µV/V + 4 mV 80 µV/V + 4 mV 130 µV/V + 6 mV 360 µV/V + 11 mV 360 µV/V + 11 mV 1300 µV/V + 45 mV Fluke 5730A Fluke 5730A w/ Fluke 5725A
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 11 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments AC Voltage3, 5 – Measure (0 to 2.2) mV (2.2 to 7.0) mV (7.0 to 22.0) mV (22 to 70) mV (70 to 220) mV (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.17 % IV + 1.3 µV 0.074 % IV + 1.3 µV 0.042 % IV + 1.3 µV 0.081 % IV + 2.0 µV 0.12 % IV + 2.5 µV 0.23 % IV + 4.0 µV 0.24 % IV + 8.0 µV 0.35 % IV + 8.0 µV 0.085 % IV + 1.3 µV 0.037 % IV + 1.3 µV 0.021 % IV + 1.3 µV 0.04 % IV + 2.0 µV 0.06 % IV + 2.5 µV 0.12 % IV + 4.0 µV 0.13 % IV + 8.0 µV 0.23 % IV + 8.0 µV 0.029 % IV + 1.3 µV 0.019 % IV + 1.3 µV 0.011 % IV + 1.3 µV 0.021 % IV + 2.0 µV 0.031 % IV + 2.5 µV 0.081 % IV + 4.0 µV 0.089 % IV + 8.0 µV 0.17 % IV + 8.0 µV 0.024 % IV + 1.5 µV 0.012 % IV + 1.5 µV 65 µV/V + 1.5 µV 0.013 % IV + 2.0 µV 0.026 % IV + 2.5 µV 0.051 % IV + 4.0 µV 0.067 % IV + 8.0 µV 0.11 % IV + 8.0 µV 0.021 % IV + 1.5 µV 85 µV/V + 1.5 µV 38 µV/V + 1.5 µV 69 µV/V + 2.0 µV 0.016 % IV + 2.5 µV 0.025 % IV + 4.0 µV 0.038 % IV + 8.0 µV 0.1 % IV + 8.0 µV Fluke 5790A
0 to 2.2 mV
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 12 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments AC Voltage3, 5 – Measure (cont) (220 to 700) mV (0.7 to 2.2) V (2.2 to 7.0) V (70 to 220) V (220 to 700) V (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 19.99) Hz (20 to 39.99) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 19.99) Hz (20 to 39.99) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.021 % IV + 1.5 µV 76 µV/V + 1.5 µV 33 µV/V + 1.5 µV 51 µV/V + 2.0 µV 79 µV/V + 2.5 µV 0.018 % IV + 4.0 µV 0.03 % IV + 8.0 µV 0.096 % IV + 8.0 µV 0.02 % IV 66 µV/V 24 µV/V 46 µV/V 71 µV/V 0.016 % IV 0.026 % IV 0.09 % IV 0.02 % IV 67 µV/V 24 µV/V 48 µV/V 81 µV/V 0.019 % IV 0.04 % IV 0.12 % IV 0.02 % IV 68 µV/V 31 µV/V 69 µV/V 98 µV/V 0.021 % IV 0.05 % IV 0.02 % IV 96 µV/V 39 µV/V 0.012 % IV 0.04 % IV Fluke 5790A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 13 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments AC Voltage3, 5 – Measure (cont) (700 to 1000) V (0 to 10) kV (10 to 75) kV (10 to 19.99) Hz (20 to 39.99) Hz (0.040 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 60 Hz 0.02 % IV 96 µV/V 37 µV/V 0.012 % IV 0.04 % IV 0.15 % IV + 0.1 V 0.15 % IV + 0.6 V Fluke 5790A Vitrek 4700A w/ HVL-100 AC Current3 – Measure (0 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (12 to 120) mA (0.12 to 2.2) A (2 to 20) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 1) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (50 to 100) Hz 300 Hz 1 kHz 3 kHz 4 kHz 5 kHz 0.4 % IV + 30 pA 0.15 % IV + 30 pA 0.06 % IV + 30 pA 0.06 % IV + 30 pA 0.4 % IV + 200 pA 0.15 % IV + 200 pA 0.06 % IV + 200 pA 0.03 % IV + 200 pA 0.4 % IV + 2 µA 0.15 % IV + 2 µA 0.06 % IV + 2 µA 0.03 % IV + 2 µA 0.15 % IV + 20 µA 0.06 % IV + 20 µA 0.03 % IV + 20 µA 0.06 % IV + 20 µA 0.4 % IV + 200 µA 0.16 % IV + 200 µA 0.08 % IV + 200 µA 0.1 % IV + 200 µA 0.016 % IV 0.019 % IV 0.027 % IV 0.051 % IV 0.063 % IV 0.075 % IV Agilent 3458A Fluke Y5020, HP 3458A Fluke Y5020, HP 3458A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 14 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments AC Current3 – Measure (cont) (20 to 1200) A 60 Hz 400 Hz 0.05 % IV 0.09 % IV Weston 327 current transformer, Fluke Y5020, HP 3458A AC Current3 – Generate (0 to 220) µA (0.2 to 2.2) mA (2.0 to 22) mA (20 to 220) mA (0.2 to 2.2) A (2.0 to 11) A (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.02 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz 280 µA/A + 20 nA 180 µA/A + 12 nA 120 µA/A + 10 nA 320 µA/A + 15 nA 1100 µA/A + 80 nA 280 µA/A + 50 nA 180 µA/A + 40 nA 120 µA/A + 40 nA 220 µA/A + 130 nA 1100 µA/A + 800 nA 280 µA/A + 500 nA 180 µA/A + 400 nA 120 µA/A + 400 nA 220 µA/A + 700 nA 1100 µA/A + 6000 nA 280 µA/A + 5 µA 180 µA/A + 4 µA 120 µA/A + 3 µA 220 µA/A + 4 µA 1100 µA/A + 12 µA 280 µA/A + 40 µA 460 µA/A + 100 µA 7000 µA/A + 200 µA 400 µA/A + 170 µA 850 µA/A + 380 µA 3300 µA/A + 750 µA Fluke 5730A Fluke 5730A w/ Fluke 5725A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 15 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments AC Current3 – Generate (cont) (2 to 20) A (20 to 100) A (50 to 100) Hz 300 Hz 1 kHz 3 kHz 4 kHz 5 kHz 60 Hz 160 µA/A 190 µA/A 270 µA/A 510 µA/A 630 µA/A 750 µA/A 500 µA/A Fluke Y5020, HP 3458A, Fluke 5725A Fluke Y5020, HP 3458A, Weston 327 CT, Vahalla 2555A Capacitance3 – Generate 1000 pF (330 to 500) pF (0.5 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.330 to 1.10) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.330 to 1.1) mF 1000 Hz (50 to 1000) Hz (50 to 400) Hz (50 to 200) Hz (50 to 100) Hz 5.0 µF/F 0.5 % IV + 10 pF 0.5 % IV + 10 pF 0.5 % IV + 10 pF 0.5 % IV + 10 pF 0.25 % IV + 100 pF 0.25 % IV + 100 pF 0.25 % IV + 300 pF 0.25 % IV + 1 nF 0.35 % IV + 3 nF 0.35 % IV + 10 nF 0.4 % IV + 30 nF 0.5 % IV + 100 nF 0.7 % IV + 300 nF 1 % IV + 300 nF GenRad 1404A Fluke 5500A
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 16 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments Capacitance3 – Measure (0.1 to 1000) pF (0 to 1) nF (1 to 10) nF (10 to 100) nF (0.1 to 1) µF (1 to 10) µF (10 to 100) µF (0.1 to 1) mF (1 to 10) mF (10 to 100) mF (0.1 to 1) F (1 to 10) F (10 to 31.8) F (0.1 to 10.0) pF (10 to 100) pF (0.1 to 1) nF (1 to 100) nF (0.1 to 10) µF 1 kHz (0.050 to 2) kHz 10 Hz to 100 kHz 100 kHz to 1 MHz (1 to 2) MHz 10 Hz to 1 MHz (1 to 2) MHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz 10 Hz to 1 kHz (1 to 10) kHz (10 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 0.01 % IV + 30 fF 0.1 % IV + 10 fF 0.1 % IV + 100 fF 0.1 % IV + 1 pF 0.1 % IV + 10 pF 0.1 % IV + 100 pF 0.1 % IV + 1 nF 0.1 % IV + 10 nF 0.1 % IV + 100 nF 0.1 % IV + 1 µF 0.1 % IV + 10 µF 0.1 % IV + 100 µF 0.1 % IV + 1 mF 0.48 % IV 0.60 % IV 0.80 % IV 0.12 % IV 0.35 % IV 0.17 % IV 0.18 % IV 0.23 % IV 0.41 % IV 0.46 % IV 0.10 % IV 0.19 % IV 0.10 % IV 0.19 % IV 0.57 % IV 1 % IV GenRad 1620A Fluke PM6304C Keysight E4980A Inductance3 – Measure (0.00 to 1.00) mH (1.00 to 10) mH (10 to 100) mH (0.100 to 1.00) mH (1 to 9.9999) H (10 to 99.999) H (100 to 999.99) H (0.050 to 2) kHz 0.1 % IV + 10 nH 0.1 % IV + 100 nH 0.1 % IV + 1 µH 0.1 % IV + 10 µH 0.1 % IV + 100 µH 0.1 % IV + 1 mH 0.1 % IV + 10 mH Fluke PM6304C
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 17 of 26 Parameter/Range4 Frequency CMC2, 6, 10 (±) Comments Inductance3 – Measure (cont) Up to 1 µH (1 to 10) µH (10 to 100) µH (0.1 to 1) mH (1 to 10) mH (10 to 100) mH (0.1 to 1) H (1 to 10) H (10 to 100) H (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz (1 to 10) kHz 10 kHz to 1 MHz (1 to 2) MHz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz (20 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz (20 to 100) Hz 100 Hz to 10 kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz (20 to 100) Hz 100 Hz to 10 kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 2) MHz 20 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz (20 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz (20 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz 1.9 % IV 0.42 % IV 0.31 % IV 0.48 % IV 0.42 % IV 0.24 % IV 0.40 % IV 0.47 % IV 0.23 % IV 0.14 % IV 0.16 % IV 0.34 % IV 0.64 % IV 0.22 % IV 0.15 % IV 0.13 % IV 0.27 % IV 0.44 % IV 0.13 % IV 0.11 % IV 0.24 % IV 1 % IV 1.2 % IV 0.13 % IV 0.11 % IV 0.24 % IV 1 % IV 1.2 % IV 0.11 % IV 0.13 % IV 0.36 % IV 0.11 % IV 0.13 % IV 0.24 % IV 0.79 % IV 0.13 % IV 0.17 % IV 0.71 % IV Keysight E4980A
to 100 H
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 18 of 26 Parameter/Equipment Range CMC2, 6 (±) Comments Oscilloscopes3 – Amplitude DC – DC Signal: 50 Ω Load 1 MΩ Load Amplitude – Square Wave: 50 Ω Load 1 MΩ Load Leveled Sine Wave – (Into 50 Ω Load) Flatness @ 50 kHz Reference Time Marker – (Into 50 Ω Load) Edge Spec (Rise Time) Amplitude Flatness (0 to 6.6) V (0 to 130) V 1 mV p-p to 6.6 Vp-p 1 mVp-p to 130 Vp-p 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 5 s to 50 ms 20 ms to 1 ns (200 to 300) ps 1 kHz to 2 MHz (200 to 350) ps (2 to 10) MHz 0.1 Hz to 50 kHz (0.050 to 100) MHz (100 to 250) MHz (250 to 550) MHz 0.25 % IV + 100 μV 0.25 % IV + 100 μV 0.25 % IV + 100 μV 0.25 % IV + 100 μV 2 % IV + 300 μV 3.5 % IV + 300 μV 4 % IV + 300 μV 6 % IV + 300 μV 1.5 % IV + 100 μV 2 % IV + 100 μV 4 % IV + 100 μV (25 + 1000t) μs/s 2.5 μs/s 900 ps 900 ps 1.5 % IV 1.5 % IV 3 % IV 4 % IV Fluke 5500A w/ SC600 scope option t is the numerical value of the time in seconds Referenced to 50 kHz Thermocouple Simulation – Generate & Measure Type B Type E (600 to 800) °C (800 to 1550) °C (1550 to 1820) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C 0.35 °C 0.28 °C 0.22 °C 0.25 °C 0.12 °C 0.09 °C 0.08 °C 0.10 °C Fluke 7526A
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 19 of 26 Parameter/Equipment Range CMC2 (±) Comments Thermocouple Simulation – Generate & Measure (cont) Type J Type K Type N Type R Type S Type T Type U (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-250 to -200) °C (-200 to -100) °C (-100 to 800) °C (800 to 1372) °C (-205 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1600) °C (1600 to 1767) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 400) °C (-200 to 0) °C (0 to 600) °C 0.14 °C 0.09 °C 0.10 °C 0.46 °C 0.16 °C 0.10 °C 0.13 °C 0.73 °C 0.23 °C 0.12 °C 0.11 °C 0.10 °C 0.12 °C 0.55 °C 0.45 °C 0.39 °C 0.28 °C 0.22 °C 0.21 °C 0.19 °C 0.23 °C 0.51 °C 0.43 °C 0.38 °C 0.29 °C 0.23 °C 0.22 °C 0.26 °C 0.35 °C 0.16 °C 0.11 °C 0.09 °C 0.16 °C 0.10 °C Fluke 7526A
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 20 of 26 V. Fluid Quantities Parameter/Equipment Range CMC2, 6, 9 (±) Comments Specific Gravity – Measuring Equipment (1.00 to 1.43) SPG 0.0011 SPG Hydrometer set Gas Flow – Measuring Equipment & Measure (0.3 to 100) SCFM (0 to 60 000) sccm 0.5 % IV 0.5 % IV or 0.04 sccm DHI Molbloc sonic nozzle system DHI Molbloc flow calibrator Leak Rate3 – Measure Down to 1.0-8 ATM cc/s He at 21 °C 6.0 % IV Leak detector standard Volume – Measuring Equipment (e.g. Flasks, Graduated Cylinders) (1 to 10 000) mL 0.065 % IV Mass comparators VI. Mechanical Parameter/Equipment Range CMC2 (±) Comments Indirect Verification of Rockwell Hardness3 HRBW: Low Medium High HRC: Low Medium High 1.2 HRBW 1.5 HRBW 1.3 HRBW 0.75 HRC 0.75 HRC 0.75 HRC Hardness blocks
1 to 10000 mL
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 21 of 26 Parameter/Equipment Range CMC2, 6, 9 (±) Comments Pressure Gages, Controllers, Transducers3 – Pneumatic Hydraulic (0 to 3) in H 2O (> 3 to 30) in H2O (0.2 to 1000) psig (0.2 to 1000) psia (0 to 10 000) psig (40 to 20 000) psig 0.000 27 in H2O 0.009 % IV 0.005 % IV 0.005 % IV + 0.0005 psia 0.08 % FS 0.01 % IV Ruska 7250LP Ruska 2465 dead weight tester Fluke 700P31 DH Instruments 50316 dead weight tester Vacuum – Gages Controllers & Transducers (10 to 1000) mmHg (0.1 to 100) mmHg 0.005 % IV + 0.03 mmHg 0.1 % IV Ruska 2465 dead weight tester MKS vacuum system Force3 – Tension & Compression, Measure & Measuring Equipment (0.1 to 1000) lbf (100 to 100 000) lbf 0.01 % IV 0.06 % IV Dead weight Load cells Scales & Balances3 Up to 5 g Up to 100 g Up to 500 g Up to 5000 g Up to 26 100 g 0.023 mg 0.048 mg 0.3 mg 3.0 mg 3.0 mg Weights or weight sets Tachometer3 – Optical Pickup (1 to 30 000) rpm 0.012 % IV + 0.6R Agilent 33250A Torque – Measuring Equipment (0.1 to 10 000) lbf·ft 0.11 % IV Dead weight, torque arms
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 22 of 26 Parameter/Equipment Range CMC2, 6, 9 (±) Comments Mass3 – Fixed Points 5000 g 3000 g 2000 g 1000 g 500 g 300 g 200 g 100 g 50 g 30 g 20 g 10 g 5 g 3 g 2 g 1 g 0.5 g 0.3 g 0.2 g 0.1 g 50 mg 30 mg 20 mg 10 mg 5 mg 3 mg 2 mg 1 mg Up to 2500 lb 1.5 mg 2.6 mg 1.1 mg 0.22 mg 0.20 mg 0.11 mg 0.10 mg 0.10 mg 36 µg 20 µg 20 µg 7.0 µg 4.6 µg 4.4 µg 3.4 µg 2.3 µg 1.3 µg 4.0 µg 4.0 µg 2.4 µg 2.4 µg 2.4 µg 2.4 µg 2.4 µg 2.2 µg 2.8 µg 3.0 µg 2.2 µg 0.01 % IV Class S mass set Class F weights Torque Arms (5 to 120) in 0.01 in Gage blocks, LMM Torque – Measure3 (0.2 to 6500) lbf·ft 0.5 % IV Torque cells Vibration – Voltage Sensitivity, Frequency Response (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 000 to 15 000) Hz 1.9 % IV 1.4 % IV 1.0 % IV 1.2 % IV 1.6 % IV 2.1 % IV 2.5 % IV Modal Shop TMS 9155 sensor calibration system
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 23 of 26 VII. Optical Quantities Parameter/Equipment Range CMC2, 6 (±) Comments Illuminance – Light Meters Spectral Irradiance (Up to 22 500) µW/cm2 (Up to 22.5) mW/cm2 (2 to 500) fc (250 to 1100) nm 250 nm 260 nm 270 nm 280 nm 290 nm 300 nm 310 nm 320 nm 330 nm 340 nm 350 nm 360 nm 370 nm 380 nm 390 nm 400 nm 450 nm 500 nm 555 nm 600 nm 654.6 nm 700 nm 800 nm 900 nm 1050 nm 1100 nm 2.7 % IV 8.9 % 8.4 % 7.5 % 7.5 % 6.8 % 5.2 % 4.4 % 4.4 % 4 % 4 % 4.3 % 3.7 % 3.7 % 3.7 % 3.7 % 3.6 % 3.6 % 3.3 % 3.3 % 3.3 % 2.9 % 2.9 % 3.5 % 3.5 % 3.5 % 3.5 % Optronic OL 220P Optronics OL-750
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 24 of 26 VIII. Thermodynamics Parameter/Equipment Range CMC2, 9 (±) Comments Dew Point – Measuring Equipment (-90 to 10) °C dp 0.25 °C dp Thunder Scientific 3900 Temperature – Measuring Equipment Triple Point Cell 0.010 °C 0.000 12 °C Fluke (Hart) 5901A-G Temperature3 – Measure (0 to 100) °C (0 to 1000) °C (1000 to 1450) °C (-200 to 660) °C 0.01 °C 0.8 °C 4.2 °C 0.008 °C Hart black stack w/ thermistor Hart Scientific 5650 Type “S” Thermocouple w/ Fluke 7526A Fluke 5699 PRT w/ Fluke 1594A Humidity – Measuring Equipment (10 to 95) % RH 0.5 % RH Thunder Scientific 2900 Temperature – Measuring Equipment w/ Dry Blocks (-95 to 140) °C (-30 to 155) °C (100 to 425) °C (425 to 660) °C (600 to 1200) °C 0.07 °C 0.06 °C 0.22 °C 0.35 °C 2.6 °C Hart Scientific 9190 w/ Fluke 5612-12 Hart Scientific 9171 w/ Fluke 5699 PRT & Fluke 1594A Hart Scientific 9173 w/ Fluke 5699 PRT & Fluke 1594A Hart Scientific 9150 w/ 5650 Type “S” thermocouple & Fluke 7526A Temperature IR – Measuring Equipment Black Body (-15 to 120) °C (35 to 200) °C (> 200 to 350) °C (> 350 to 500) °C 1.0 °C 1.0 °C 2.0 °C 3.0 °C Hart Scientific 4180 IR target Hart Scientific 4181 IR target λ = (8 to 14) µm Ɛ = 0.9 to 1.0
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 25 of 26 Parameter/Equipment Range CMC2, 9 (±) Comments Temperature – Measuring Equipment w/ Calibration Bath (-40 to 100) °C (0.0 to 100) °C (100 to 180) °C (170 to 500) °C 0.014 °C 0.010 °C 0.014 °C 0.021 °C Hart Scientific 7040 oil bath w/ Fluke 5699 PRT & Fluke 1594A Hart Scientific 7040 oil bath w/ Hart Blackstack & thermistor Hart Scientific 6045 oil bath w/ Fluke 5699 PRT & Fluke 1594A Hart Scientific 6050 oil bath w/ Fluke 5699 PRT & Fluke 1594A IX. Time & Frequency Parameter/Equipment Range CMC2, 9 (±) Comments Stop Watches & Timers 3 (0.2 to 10 000) s (+10 to -10) s/day 1.8 parts in 107 + trigger error 0.05 s/day HP 53131A Timometer TM4500 Frequency – Measuring Equipment 10 000 000 Hz 0.01 Hz to 80 MHz (0.1 to 3000) MHz 50 pHz/Hz 2 µHz/Hz 10 nHz/Hz 2 µHz/Hz 10 nHz/Hz TrueTime XL-DC GPS receiver Agilent 33250A 33250A synchronized w/ GPS Agilent 8648C 8648C synchronized w/ GPS Frequency – Measure 10 MHz 0.1 Hz to 225 MHz (0.1 to 3000) MHz 100 pHz/Hz 0.19 µHz/Hz 1 nHz/Hz 0.19 µHz/Hz 1 nHz/Hz TrueTime XL-DC GPS receiver Agilent 53131A frequency counter 53131A synchronized w/ GPS Agilent 53131A channel 3 53131A synchronized w/ GPS ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service where noted.
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2724.01) Revised 10/15/2025 Page 26 of 26 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Where ranges are not specified, the CMC stated is for the cardinal points only. 5 This calibration is performed in Absolute Measure Mode. 6 In the statement of CMC , percentages are to be read as percent of reading unless noted otherwise, IV is defined as the indicated value, FS is defined as full scale, L is the numerical value of the nominal length of the device measured in inches, D is the diameter of the device in inches; R is the resolution of the unit under test. 7 Contact the laboratory for information on availability of service for specific gasses not listed, gasses that are not listed are not considered accredited services. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
27ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.